Produits VOOHU WHPT-EQ200 Planar Transformers: Select by Topology and Output

Gamme de transformateurs

WHPT-EQ200 Planar Transformers: Select by Topology and Output

Select multilayer-PCB-winding planar transformers for compact isolated DC-DC designs. WHPT-EQ200 includes 60 W and 71 W flyback families plus 90 W and 120 W active-clamp forward families, each with 3.3 V, 5 V, 12 V and 24 V output design options. Confirm the topology first, then compare inductance, turns ratio, output current and thermal requirements. Request samples or pricing directly for a selected part.

Pour les commandes OEM et en volume. MOQ : une bobine, un plateau ou un tube complet par référence.

  • Usines en propre : connecteurs à Dongguan, composants magnétiques à Mianyang
  • Plus de 1 500 clients, dont plus de 150 sociétés cotées
  • Certifié ISO 9001 et ISO 14001

Recherche et sélection de références

Trouver des références pour WHPT-EQ200 Planar Transformers: Select by Topology and Output

Le tableau utilise les fiches produits actuelles du site anglophone, les critères de sélection publiés et les liens vers les fichiers techniques propres à chaque référence.

* Colonnes Image et Référence figées · faites glisser horizontalement pour consulter toutes les caractéristiques

Résultats de la sélection pour WHPT-EQ200 Planar Transformers: Select by Topology and Output
Image Référence Fiche technique Comparer Téléchargements ModelPower(W)Inductance(μH)Lk(μH Max)Rapport de transformationIast(A)Output(V/A) Échantillon
VOOHU WHPT-EQ200-026 WHPT-EQ200 Planar Transformers: Select by Topology and Output WHPT-EQ200-026 SPEC WHPT-EQ200-120W Series1202800.51:1:0.5TBD24V/5A
VOOHU WHPT-EQ200-025 WHPT-EQ200 Planar Transformers: Select by Topology and Output WHPT-EQ200-025 SPEC WHPT-EQ200-120W Series1202800.51:0.5:0.5TBD12V/10A
VOOHU WHPT-EQ200-024 WHPT-EQ200 Planar Transformers: Select by Topology and Output WHPT-EQ200-024 SPEC WHPT-EQ200-120W Series1202800.51:0.25:0.5TBD5V/24A
VOOHU WHPT-EQ200-023 WHPT-EQ200 Planar Transformers: Select by Topology and Output WHPT-EQ200-023 SPEC WHPT-EQ200-120W Series1202800.51:0.166:0.666TBD3.3V/36A

Liens rapides vers les familles de produits

Commencer par la famille de produits

Les quantités indiquées reflètent les données produits actuellement publiées.

Comment sélectionner

Une méthode de sélection pratique

Affinez successivement les champs publiés, comparez les références restantes et vérifiez les fichiers propres à chaque référence avant l’intégration dans la conception.

  1. 01

    Establish the topology

    Distinguish flyback, active-clamp forward and other topologies. Include the controller or reference circuit.

  2. 02

    Define input and output conditions

    Provide input range, output voltage/current, switching frequency, duty cycle and startup conditions.

  3. 03

    Review magnetics and thermal design

    Compare inductance definitions, leakage, ratio, DCR and winding current. Check temperature rise, flux and cooling.

  4. 04

    Use part-specific files and validate

    Check pins, polarity, pads, insulation and assembly documents. Validate full-load and worst-case operation in the target circuit.

Principaux paramètres de sélection

Ce que chaque filtre vous aide à déterminer

01

Rated power

The 60 W and 71 W parts are flyback; the 90 W and 120 W parts are active-clamp forward. Power and topology move together here.

02

Inductance

Primary magnetising inductance. Read it with switching frequency and input voltage, which together set the flux swing.

03

Inductance de fuite

Quoted as a maximum. Leakage does not reach the secondary; it drives the spike your clamp or snubber has to absorb.

04

Rapport de transformation

Stated per winding set. With the input range and the topology it produces the listed output voltage, before regulation.

05

Output design point

The voltage and current the part was designed around inside a converter. It is not an output you can load directly.

Comparaison des familles de produits

Comparer les familles de produits publiées

Utilisez ce résumé pour orienter la sélection, puis vérifiez chaque valeur requise sur la ligne de la référence exacte et dans les fichiers techniques associés.

Revenir au sélecteur ↑
ModelRéférencesPower(W)Inductance(μH)Lk(μH Max)Rapport de transformationIast(A)Output(V/A)Action
WHPT-EQ200-60W Series460210.51:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.55.4, 63.3V/18A, 5V/12A, 12V/5A, 24V/2.4AFiltrer →
WHPT-EQ200-71W Series471180.51:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.56.3, 6.63.3V/21A, 5V/14A, 12V/5.9A, 24V/2.9AFiltrer →
WHPT-EQ200-90W Series4902800.51:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5TBD3.3V/27A, 5V/18A, 12V/7.5A, 24V/3.7AFiltrer →
WHPT-EQ200-120W Series41202800.51:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5TBD3.3V/36A, 5V/24A, 12V/10A, 24V/5AFiltrer →

Performances techniques et adéquation à l’application

Validez le contexte complet de la conception

L’adéquation à l’application dépend de la référence. Utilisez les critères du catalogue pour établir une présélection, puis validez la conception à l’aide des fichiers techniques associés.

Analyse de l’application

Telecom equipment and compact isolated DC-DC

  • Filter by height, input range and output requirements, then confirm topology before loss and thermal assessment.
Analyse de l’application

PoE powered devices and industrial auxiliary supplies

  • For PoE, check the PD controller and system power budget. For industrial auxiliary power, review input range and insulation separately rather than applying a blanket family-wide conclusion.
Obtenir une assistance technique →

Téléchargements et ressources techniques

Trouver des fichiers par référence

Recherchez un SKU complet ou partiel, puis ouvrez sa fiche technique, son modèle 3D ou son empreinte PCB sans revenir au tableau des produits.

16
Fiches techniques PDF répertoriées
16
Jeux de fichiers 3D répertoriés
16
Empreintes PCB répertoriées

Le contenu produit publié par VOOHU est vérifié par son équipe technique. Les caractéristiques, les téléchargements et les informations d’assistance technique sont associés à des références précises afin que vous puissiez les vérifier avant de demander des échantillons ou un devis.

Présentation de la catégorie

What planar construction changes, and what it does not

The construction buys repeatability and height. It does not turn the part into a finished power supply.

01

Windings are PCB layers

Instead of wire on a bobbin, the windings are copper layers in a multilayer board sandwiched between low-profile core halves. That gives a very repeatable build, low height and good thermal contact with the board. It also fixes the turns count in the layout, which is why the range is organised by design point.

02

Topology comes before power

The range splits into flyback families and active-clamp forward families. These store and transfer energy differently, so a transformer designed for one will not behave correctly in the other even at the same output power. Confirm your converter topology first; power and output voltage narrow it afterwards.

03

Output entries are design points

An entry such as 12 V at 10 A describes the operating point the transformer was designed around inside a complete converter, not a supply you can connect a load to. The controller, switching devices, rectification and output filtering are all yours. Leakage and thermal behaviour still need verifying on the real board.

FAQ et guides associés

Questions avant l’intégration dans la conception

Ces réponses guident le parcours sur la page. Les limites techniques propres à chaque référence restent définies par les fichiers techniques associés.

How does a planar transformer differ from a conventional wire-wound transformer?

A planar design uses a flat winding arrangement; this family specifically uses multilayer PCB windings. It offers a low-profile construction option, but losses, leakage, parasitic capacitance and cost remain design-specific. Not every planar transformer is inherently more efficient than a conventional design.

How do I choose between 60 W, 71 W, 90 W and 120 W families?

Start with topology: 60/71 W are flyback families, while 90/120 W are active-clamp forward. Then select the specific part for the required output voltage and current. The power label does not replace input-range, frequency, thermal or insulation validation; every voltage/current pair need not multiply to exactly the family label.

Does a 12 V or 24 V output entry mean I can connect DC and use it directly?

No. A transformer is a magnetic component within a converter, not a regulated DC-DC module. The output depends on topology, controller, switching frequency, ratio, rectification and feedback. Provide input range, output requirements and the controller so the complete circuit can be assessed.

How does 0.5 μH leakage differ from 21, 18 or 280 μH inductance?

Leakage and inductance are different parameters with different measurement arrangements. The 60 W table lists 21 μH±10%, the 71 W table lists 18 μH±10%, and 90/120 W list 280 μH minimum. Leakage is 0.5 μH maximum. Do not relabel 280 μH as a universal typical value or treat leakage as the working inductance.

Can all of these planar transformers be used in LLC or PoE supplies?

No blanket compatibility should be assumed. The documents specify flyback or active-clamp forward, not LLC merely because the construction is planar. The 60/71 W documents mention PoE applications, but the overall PoE power budget, PD controller, losses and compliance still need system review. Transformer power alone is insufficient.

If temperature rise is high, should I simply choose a higher-power part?

Not necessarily. Review input voltage, frequency, flux, winding RMS current, copper and core losses, and cooling. A higher-power family may also change topology and inductance, so it is not a direct replacement. Share operating conditions and thermal measurements for FAE assessment.

Are planar transformers with the same dimensions drop-in replacements?

Dimensions alone are insufficient. Compare topology, ratio, primary inductance, leakage, winding resistance, insulation, polarity and pads. FAE can identify candidates and explain differences, followed by electrical and thermal validation.

How do I request planar transformer pricing, samples or customization?

For a known part, request pricing with the quantity and destination. For a new project, start with topology, input range, output voltage/current and height limits; attach the current datasheet for replacement review. Custom electrical design, mechanics, tooling and timing are evaluated per project.

Assistance technique

Poursuivre après la sélection du produit

Envoyez la référence candidate et la condition à examiner. Vous pourrez demander des échantillons une fois la sélection précisée ; les questions commerciales peuvent être abordées au cours du même échange technique.

  1. 1Références sélectionnées
  2. 2Analyse technique
  3. 3Demande d’échantillons
  4. 4Échange commercial

Pour une étude de remplacement

  • Référence d’origine et fiche technique

    Indiquez la révision du document

  • Conditions de fonctionnement

    Température, tension d’isolement et conditions de courant PoE prises comme référence

  • Contraintes du boîtier

    Nombre de broches, pas et espacement entre les rangées de broches

  • Phase du projet et volume annuel

    Pour faciliter la priorisation des échantillons et de l’évaluation

  • Date d’analyse souhaitée

    Date à laquelle vous avez besoin de références candidates et d’un comparatif des différences

L’analyse technique identifie les références candidates et explique les différences.

Pour des échantillons et un devis

  • Références candidates

    Issues du sélecteur ou de l’analyse technique

  • Quantité et phase du projet

    Prototypage / présérie / production

  • Date de livraison requise

    Précisez séparément les délais des échantillons et de la production

  • Documentation requise

    Documents de conformité, déclarations de matières ou rapports de tiers

Des échantillons sont disponibles pour évaluation, et certaines références sont gratuites. Notre équipe FAE se fera un plaisir de confirmer les options pour votre projet. L’équipe commerciale répond les jours ouvrés.

Pour les commandes OEM et en volume. MOQ : une bobine, un plateau ou un tube complet par référence.

Vos informations seront utilisées uniquement pour répondre à cette demande d’assistance.

Études de remplacement publiées Voir toutes les alternatives

Comparaison des paramètres

Comparer les références sélectionnées

Les différences sont présentées pour analyse ; confirmez les valeurs finales et les révisions des fichiers dans la fiche technique propre à chaque référence.