WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers

Compare 120 W planar transformers for isolated active-clamp forward DC-DC designs. The four parts, WHPT-EQ200-023 through WHPT-EQ200-026, correspond to 3.3 V, 5 V, 12 V and 24 V output design options. The listed primary inductance is 280 μH minimum. Confirm topology and input/output conditions before choosing a part and requesting samples.

Pour les commandes OEM et en volume. MOQ : une bobine, un plateau ou un tube complet par référence.

  • Usines en propre : connecteurs à Dongguan, composants magnétiques à Mianyang
  • Plus de 1 500 clients, dont plus de 150 sociétés cotées
  • Certifié ISO 9001 et ISO 14001

Recherche et sélection de références

Trouver des références pour WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers

Le tableau utilise les fiches produits actuelles du site anglophone, les critères de sélection publiés et les liens vers les fichiers techniques propres à chaque référence.

* Colonnes Image et Référence figées · faites glisser horizontalement pour consulter toutes les caractéristiques

Résultats de la sélection pour WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers
Image Référence Fiche technique Comparer Téléchargements ModelPower(W)Inductance(μH)Lk(μH Max)Rapport de transformationIast(A)Output(V/A) Échantillon
VOOHU WHPT-EQ200-026 WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers WHPT-EQ200-026 SPEC WHPT-EQ200-120W Series1202800.51:1:0.5TBD24V/5A
VOOHU WHPT-EQ200-025 WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers WHPT-EQ200-025 SPEC WHPT-EQ200-120W Series1202800.51:0.5:0.5TBD12V/10A
VOOHU WHPT-EQ200-024 WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers WHPT-EQ200-024 SPEC WHPT-EQ200-120W Series1202800.51:0.25:0.5TBD5V/24A
VOOHU WHPT-EQ200-023 WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers WHPT-EQ200-023 SPEC WHPT-EQ200-120W Series1202800.51:0.166:0.666TBD3.3V/36A

Liens rapides vers les familles de produits

Commencer par la famille de produits

Les quantités indiquées reflètent les données produits actuellement publiées.

Comment sélectionner

Guide de sélection : WHPT-EQ200 Planar Transformers: Select by Topology and Output

Les étapes de sélection, l’explication des paramètres et la comparaison des séries pour WHPT-EQ200 Planar Transformers: Select by Topology and Output sont réunies sur une seule page. Confirmez-y la série, puis utilisez cette liste pour les références, les fichiers et les échantillons.

Ouvrir le guide de sélection : WHPT-EQ200 Planar Transformers: Select by Topology and Output →

Téléchargements et ressources techniques

Trouver des fichiers par référence

Recherchez un SKU complet ou partiel, puis ouvrez sa fiche technique, son modèle 3D ou son empreinte PCB sans revenir au tableau des produits.

4
Fiches techniques PDF répertoriées
4
Jeux de fichiers 3D répertoriés
4
Empreintes PCB répertoriées

Le contenu produit publié par VOOHU est vérifié par son équipe technique. Les caractéristiques, les téléchargements et les informations d’assistance technique sont associés à des références précises afin que vous puissiez les vérifier avant de demander des échantillons ou un devis.

FAQ et guides associés

Questions avant l’intégration dans la conception

Ces réponses guident le parcours sur la page. Les limites techniques propres à chaque référence restent définies par les fichiers techniques associés.

Which topology is specified for the 120 W family?

The current datasheet specifies active-clamp forward, not universal LLC or arbitrary converter use. Check input voltage, frequency, duty cycle, winding connections and core-reset requirements against the controller reference design before sample validation.

Which 120 W part should I review for 24 V / 5 A?

WHPT-EQ200-026 lists 24 V / 5 A as a candidate for the corresponding active-clamp forward design. Also review input range, frequency, rectification and thermal design. The 120 W voltage/current product does not remove the need for operating-condition validation.

How should I compare inductance and leakage for the 120 W family?

The table lists 280 μH minimum and 0.5 μH maximum leakage. Preserve minimum, tolerance and maximum qualifiers, and compare at 100 kHz, 1 V with the specified connections. Measurement frequency is not necessarily the required converter switching frequency.

Can I fill the missing 90/120 W Isat value from a similar part?

No. The current 90/120 W tables do not give an Isat value. TBD does not mean zero, unlimited or the same as 60/71 W. If a limit is required, obtain engineering documentation appropriate to the topology, flux and operating conditions.

How do I request 120 W samples or replacement review?

For a selected part from WHPT-EQ200-023 to WHPT-EQ200-026, send the quantity and destination for pricing. For selection or replacement, provide input range, output voltage/current, the active-clamp forward controller and height limits. Sales will coordinate FAE matching.

Assistance technique

Poursuivre après la sélection du produit

Envoyez la référence candidate et la condition à examiner. Vous pourrez demander des échantillons une fois la sélection précisée ; les questions commerciales peuvent être abordées au cours du même échange technique.

  1. 1Références sélectionnées
  2. 2Analyse technique
  3. 3Demande d’échantillons
  4. 4Échange commercial

Pour une étude de remplacement

  • Référence d’origine et fiche technique

    Indiquez la révision du document

  • Conditions de fonctionnement

    Température, tension d’isolement et conditions de courant PoE prises comme référence

  • Contraintes du boîtier

    Nombre de broches, pas et espacement entre les rangées de broches

  • Phase du projet et volume annuel

    Pour faciliter la priorisation des échantillons et de l’évaluation

  • Date d’analyse souhaitée

    Date à laquelle vous avez besoin de références candidates et d’un comparatif des différences

L’analyse technique identifie les références candidates et explique les différences.

Pour des échantillons et un devis

  • Références candidates

    Issues du sélecteur ou de l’analyse technique

  • Quantité et phase du projet

    Prototypage / présérie / production

  • Date de livraison requise

    Précisez séparément les délais des échantillons et de la production

  • Documentation requise

    Documents de conformité, déclarations de matières ou rapports de tiers

Des échantillons sont disponibles pour évaluation, et certaines références sont gratuites. Notre équipe FAE se fera un plaisir de confirmer les options pour votre projet. L’équipe commerciale répond les jours ouvrés.

Pour les commandes OEM et en volume. MOQ : une bobine, un plateau ou un tube complet par référence.

Vos informations seront utilisées uniquement pour répondre à cette demande d’assistance.

Études de remplacement publiées Voir toutes les alternatives

Comparaison des paramètres

Comparer les références sélectionnées

Les différences sont présentées pour analyse ; confirmez les valeurs finales et les révisions des fichiers dans la fiche technique propre à chaque référence.