Rated power
The 60 W and 71 W parts are flyback; the 90 W and 120 W parts are active-clamp forward. Power and topology move together here.
トランス製品
Select multilayer-PCB-winding planar transformers for compact isolated DC-DC designs. WHPT-EQ200 includes 60 W and 71 W flyback families plus 90 W and 120 W active-clamp forward families, each with 3.3 V, 5 V, 12 V and 24 V output design options. Confirm the topology first, then compare inductance, turns ratio, output current and thermal requirements. Request samples or pricing directly for a selected part.
OEM・量産向けのご注文を承ります。最小発注数量(MOQ)は品番ごとにリール、トレイまたはチューブ 1 梱包分です。
型番検索・選定
この表では、海外サイトの現行製品データ、公開済みの選定項目、型番別の技術資料リンクを使用しています。
※画像列と型番列は固定されています。横にドラッグしてすべての仕様を確認できます
| 画像 | 型番 | データシート | 比較 | ダウンロード | Model | Power(W) | Inductance(μH) | Lk(μH Max) | 巻数比 | Iast(A) | Output(V/A) | サンプル |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
WHPT-EQ200-022 | SPEC | WHPT-EQ200-90W Series | 90 | 280 | 0.5 | 1:1:0.5 | TBD | 24V/3.7A |
|
||
|
WHPT-EQ200-021 | SPEC | WHPT-EQ200-90W Series | 90 | 280 | 0.5 | 1:0.5:0.5 | TBD | 12V/7.5A |
|
||
|
WHPT-EQ200-020 | SPEC | WHPT-EQ200-90W Series | 90 | 280 | 0.5 | 1:0.25:0.5 | TBD | 5V/18A |
|
||
|
WHPT-EQ200-019 | SPEC | WHPT-EQ200-90W Series | 90 | 280 | 0.5 | 1:0.166:0.666 | TBD | 3.3V/27A |
|
選択した条件を広げるか、現在の検索条件をクリアしてください。
製品ファミリーのクイックリンク
件数は現在公開中の製品データに基づきます。
選定方法
公開項目を順に絞り込み、残った候補を比較して、設計採用前に型番別資料を確認してください。
Distinguish flyback, active-clamp forward and other topologies. Include the controller or reference circuit.
Provide input range, output voltage/current, switching frequency, duty cycle and startup conditions.
Compare inductance definitions, leakage, ratio, DCR and winding current. Check temperature rise, flux and cooling.
Check pins, polarity, pads, insulation and assembly documents. Validate full-load and worst-case operation in the target circuit.
主な選定パラメータ
The 60 W and 71 W parts are flyback; the 90 W and 120 W parts are active-clamp forward. Power and topology move together here.
Primary magnetising inductance. Read it with switching frequency and input voltage, which together set the flux swing.
Quoted as a maximum. Leakage does not reach the secondary; it drives the spike your clamp or snubber has to absorb.
Stated per winding set. With the input range and the topology it produces the listed output voltage, before regulation.
The voltage and current the part was designed around inside a converter. It is not an output you can load directly.
| Model | 型番数 | Power(W) | Inductance(μH) | Lk(μH Max) | 巻数比 | Iast(A) | Output(V/A) | 操作 |
|---|---|---|---|---|---|---|---|---|
| WHPT-EQ200-60W Series | 4 | 60 | 21 | 0.5 | 1:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5 | 5.4, 6 | 3.3V/18A, 5V/12A, 12V/5A, 24V/2.4A | 絞り込み → |
| WHPT-EQ200-71W Series | 4 | 71 | 18 | 0.5 | 1:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5 | 6.3, 6.6 | 3.3V/21A, 5V/14A, 12V/5.9A, 24V/2.9A | 絞り込み → |
| WHPT-EQ200-90W Series | 4 | 90 | 280 | 0.5 | 1:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5 | TBD | 3.3V/27A, 5V/18A, 12V/7.5A, 24V/3.7A | 絞り込み → |
| WHPT-EQ200-120W Series | 4 | 120 | 280 | 0.5 | 1:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5 | TBD | 3.3V/36A, 5V/24A, 12V/10A, 24V/5A | 絞り込み → |
技術性能・用途適合性
用途への適合性は型番ごとに異なります。カタログ項目で候補を絞り込み、リンク先の技術資料で設計要件への適合を確認してください。
ダウンロード・技術資料
SKUの全部または一部を検索し、製品表に戻らずにデータシート、3Dモデル、PCBフットプリントを開けます。
代表的な入手可能資料を表示しています。特定のSKUは検索して確認してください。
VOOHUが公開する製品情報は、エンジニアリングチームが確認しています。仕様、ダウンロード資料、技術サポート情報は型番ごとに紐付けられているため、サンプルや見積もりを依頼する前に確認できます。
カテゴリー概要
The construction buys repeatability and height. It does not turn the part into a finished power supply.
Instead of wire on a bobbin, the windings are copper layers in a multilayer board sandwiched between low-profile core halves. That gives a very repeatable build, low height and good thermal contact with the board. It also fixes the turns count in the layout, which is why the range is organised by design point.
The range splits into flyback families and active-clamp forward families. These store and transfer energy differently, so a transformer designed for one will not behave correctly in the other even at the same output power. Confirm your converter topology first; power and output voltage narrow it afterwards.
An entry such as 12 V at 10 A describes the operating point the transformer was designed around inside a complete converter, not a supply you can connect a load to. The controller, switching devices, rectification and output filtering are all yours. Leakage and thermal behaviour still need verifying on the real board.
よくあるご質問・関連ガイド
ここではページの利用手順に沿ってご案内します。型番固有の技術限界は、リンク先の技術資料で確認してください。
A planar design uses a flat winding arrangement; this family specifically uses multilayer PCB windings. It offers a low-profile construction option, but losses, leakage, parasitic capacitance and cost remain design-specific. Not every planar transformer is inherently more efficient than a conventional design.
Start with topology: 60/71 W are flyback families, while 90/120 W are active-clamp forward. Then select the specific part for the required output voltage and current. The power label does not replace input-range, frequency, thermal or insulation validation; every voltage/current pair need not multiply to exactly the family label.
No. A transformer is a magnetic component within a converter, not a regulated DC-DC module. The output depends on topology, controller, switching frequency, ratio, rectification and feedback. Provide input range, output requirements and the controller so the complete circuit can be assessed.
Leakage and inductance are different parameters with different measurement arrangements. The 60 W table lists 21 μH±10%, the 71 W table lists 18 μH±10%, and 90/120 W list 280 μH minimum. Leakage is 0.5 μH maximum. Do not relabel 280 μH as a universal typical value or treat leakage as the working inductance.
No blanket compatibility should be assumed. The documents specify flyback or active-clamp forward, not LLC merely because the construction is planar. The 60/71 W documents mention PoE applications, but the overall PoE power budget, PD controller, losses and compliance still need system review. Transformer power alone is insufficient.
Not necessarily. Review input voltage, frequency, flux, winding RMS current, copper and core losses, and cooling. A higher-power family may also change topology and inductance, so it is not a direct replacement. Share operating conditions and thermal measurements for FAE assessment.
Dimensions alone are insufficient. Compare topology, ratio, primary inductance, leakage, winding resistance, insulation, polarity and pads. FAE can identify candidates and explain differences, followed by electrical and thermal validation.
For a known part, request pricing with the quantity and destination. For a new project, start with topology, input range, output voltage/current and height limits; attach the current datasheet for replacement review. Custom electrical design, mechanics, tooling and timing are evaluated per project.
エンジニアサポート
候補型番と、確認が必要な条件をお送りください。候補が明確になった後にサンプル支援を追加でき、商取引に関するご質問も同じ技術相談の中でご相談いただけます。
資料のリビジョンも記載してください
温度、絶縁電圧、PoE電流の条件
ピン数、ピッチ、ピン列間隔
サンプルと評価の優先度確認に使用します
候補と相違点の比較が必要な時期
エンジニア確認により候補型番を選び、相違点をご説明します。
選定表またはエンジニア確認で選んだ型番
試作/パイロット生産/量産
サンプルと量産の時期を分けて記載してください
適合資料、材料宣言、第三者機関レポートなど
サンプルは評価用にご用意しており、一部の型番は無償です。プロジェクトに合わせた選択肢はFAEチームがご案内します。営業担当者より営業日にご回答します。