VOOHU Ethernet PHY Devices製品

イーサネットインターフェースIC製品

Ethernet PHY Devices

The range covers 100M, 1G and 2.5G links in single-port and eight-port devices, with RMII, MII, RGMII, SGMII and QSGMII on the MAC side. Start from the interface your host controller provides, then narrow by speed, port count, fibre support and temperature grade.

型番検索・選定

Ethernet PHY Devicesの型番を検索

この表では、海外サイトの現行製品データ、公開済みの選定項目、型番別の技術資料リンクを使用しています。

※画像列と型番列は固定されています。横にドラッグしてすべての仕様を確認できます

Ethernet PHY Devicesの選定結果
画像 型番 データシート 比較 ダウンロード シリーズデータレートポート数MACインターフェースV(if)銅線ポート光ポートモード温度パッケージサイズ サンプル
VOOHU JL2308-PC Ethernet PHY Devices JL2308-PC SPEC JL2308シリーズ1G8QSGMIINA10 Bsae-TNAQSGMII-COP0~70℃LQFP12820*14 mm
VOOHU JL2308-PI Ethernet PHY Devices JL2308-PI SPEC JL2308シリーズ1G8QSGMIINA10 Bsae-TNAQSGMII-COP-40~85℃LQFP12820*14 mm

選定方法

Selecting an Ethernet PHY in four steps

MAC interface first, then speed and ports, then fibre, then temperature and package.

  1. 01

    Start from the MAC interface

    Confirm what your host controller provides: RMII, MII, RGMII, SGMII or QSGMII. These are not interchangeable, and the wrong choice cannot be fixed in software.

  2. 02

    Fix speed and port count

    100M, 1G or 2.5G, and one port or eight. Eight-port devices aggregate to the host over QSGMII, so confirm the host has that bandwidth.

  3. 03

    Decide on fibre

    Some series support 100Base-FX or 1000Base-X, others are copper only. If the design needs a fibre port, check the specific part number rather than the series.

  4. 04

    Pick the temperature grade

    Suffixes separate 0 to 70, minus 40 to 85 and minus 40 to 105 degrees. Choose against the enclosure's internal temperature, not the room.

Parameters

Reading Ethernet PHY specifications

The MAC interface and the temperature suffix decide compatibility more than speed does.

01

Link speed

100M, 1G or 2.5G depending on series. All devices also support 10Base-T on the copper side, so legacy links remain available.

02

Port count

Single port for most series, or eight ports on the JL2308 and JL2388. Eight-port devices need a QSGMII-capable host.

03

MAC interface

RMII, MII, RGMII, SGMII or QSGMII. This has to match the host controller exactly; no external conversion makes two of them equivalent.

04

Fibre support

100Base-FX on parts of the 100M range, 1000Base-X on JL2201 and 2500Base-X on JL4201. Several series are copper only, marked NA.

05

Temperature grade

The suffix carries it: NC for 0 to 70, NI for minus 40 to 85, NE for minus 40 to 105 degrees. Confirm the grade on the exact part number.

06

パッケージ

From QFN24 at 4 by 4 millimetres up to LQFP128 at 14 by 14. Pin count rises with port count and interface width.

比較

Ethernet PHY series side by side

Speed, port count and MAC interface together define which series fits a design.

選定表に戻る ↑
シリーズ型番数データレートポート数MACインターフェースV(if)銅線ポート光ポートモード温度パッケージサイズ操作
JL1101シリーズ1100M1RMII1.8V10 Bsae-T100 Base-FXRMII-COP-40~85℃QFN244*4 mm絞り込み →
JL1111シリーズ4100M1MII1.8V10 Bsae-TNA, 100 Base-FXMII-COP0~70℃, -40~85℃, -40~105℃QFN325*5 mm, 未指定絞り込み →
JL2101シリーズ51G1RGMII1.8V10 Bsae-TNARGMII-COP0~70℃, -40~85℃, -40~105℃QFN405*5 mm絞り込み →
JL2201シリーズ21G1RGMII1.8V10 Bsae-T1000 Base-XRGMII-COP0~70℃, -40~85℃QFN486*6 mm絞り込み →
JL2308シリーズ21G8QSGMIINA10 Bsae-TNAQSGMII-COP0~70℃, -40~85℃LQFP12820*14 mm絞り込み →
JL2388シリーズ21G8QSGMIINA10 Bsae-TNAQSGMII-COP0~70℃, -40~85℃LQFP12820*14 mm絞り込み →
JL4201シリーズ22.5G1SGMIINA10 Bsae-T2500 Base-X(H)SGMII-COP0~70℃, -40~85℃QFN486*6 mm絞り込み →

用途別確認

Where these Ethernet PHY devices are used

Confirm the host interface, the link speed and the environment the board runs in.

用途別確認

Industrial controllers and gateways

  • Confirm the host MAC interface and choose the minus 40 to 85 or minus 40 to 105 grade to suit the cabinet temperature.
用途別確認

EtherCAT and fieldbus devices

  • The JL1111 range includes an EtherCAT variant. Confirm the protocol requirement and the MII timing before committing to a part.
用途別確認

Multi-port switch boards

  • Eight-port devices aggregate over QSGMII. Verify the host provides QSGMII and that the layout can carry the serial lanes cleanly.
用途別確認

Fibre uplinks and media converters

  • Check which specific part number supports 100Base-FX, 1000Base-X or 2500Base-X, then confirm the optical module matches.
技術サポートに相談 →

Documents

Ethernet PHY datasheets and reference designs

Datasheets carry the pinout, reference schematic and layout guidance for each series.

18
PDFデータシート掲載数
0
3Dファイル掲載数
0
PCBフットプリント掲載数

VOOHUが公開する製品情報は、エンジニアリングチームが確認しています。仕様、ダウンロード資料、技術サポート情報は型番ごとに紐付けられているため、サンプルや見積もりを依頼する前に確認できます。

カテゴリー概要

Choosing an イーサネットPHY: interface before speed

The most common selection error here is starting from link speed. The MAC interface is the constraint that cannot be worked around.

01

The MAC interface decides compatibility

RMII, MII, RGMII, SGMII and QSGMII are different electrical and timing arrangements, not tiers of the same thing. A host that provides RGMII cannot drive an RMII device, and no software setting bridges them. Establish what your controller offers first, because it eliminates most of the range before speed is even considered.

02

Copper, fibre, or both

Every device here supports copper, including 10Base-T. Fibre is selective: 100Base-FX appears on parts of the 100M range, 1000Base-X on the JL2201 and 2500Base-X on the JL4201. Fibre support is stated per part number rather than per series, so one variant of a series may have it and another may not.

03

Temperature grade is in the suffix

The letters after the base number carry the rating. NC covers 0 to 70 degrees, NI covers minus 40 to 85, NE covers minus 40 to 105. Select against the temperature inside the enclosure at the highest ambient the product is rated for, not against room temperature.

よくあるご質問

Ethernet PHY questions engineers ask

Answers cover interface choice, fibre support, temperature grades and layout.

Which MAC interface should I choose?

Whichever your host controller provides. RMII, MII, RGMII, SGMII and QSGMII are different electrical and timing schemes, not performance tiers. A host with RGMII cannot drive an RMII device and no software setting bridges them. Confirm the controller's interface first, then filter the PHY range on it.

What speeds does this range cover?

100M on the JL1101 and JL1111 series, 1G on the JL2101, JL2201, JL2308 and JL2388, and 2.5G on the JL4201. All devices also support 10Base-T on copper. There are no 5G or 10G devices in this range, so if you need those speeds, tell us and we will check availability.

Which parts support fibre?

100Base-FX appears on the JL1101 and on several JL1111 variants. 1000Base-X is supported on the JL2201 and 2500Base-X on the JL4201. Other series are copper only. Fibre support is defined per part number, so check the exact suffix rather than assuming it applies across a series.

What do the NC, NI and NE suffixes mean?

They carry the temperature grade. NC is 0 to 70 degrees, NI is minus 40 to 85, and NE is minus 40 to 105. Choose against the temperature inside your enclosure at the highest rated ambient, allowing for the heat the board itself generates, not against room temperature.

Is there an EtherCAT option?

Yes. The JL1111 series includes a variant identified as EtherCAT in the part number. Note that this variant is listed without fibre support, unlike other JL1111 parts. If your design needs EtherCAT, specify it at enquiry so the right variant is quoted.

How do eight-port devices connect to the host?

The JL2308 and JL2388 aggregate all eight links to the host over QSGMII, a serial interface that carries multiple lanes on one pair. Your host must provide QSGMII and enough bandwidth for the aggregate traffic. The layout also has to carry those serial lanes with controlled impedance.

Are these devices automotive qualified?

The range is specified to commercial, industrial and extended industrial temperature grades, up to minus 40 to 105 degrees. That is not the same as automotive qualification under AEC-Q100. If your programme requires automotive qualification, tell us and we will confirm what is available.

How do I request Ethernet PHY samples or a quote?

With a complete part number, send the part number, quantity, delivery region and the date you need it. If you are still selecting, send the host controller and its MAC interface, the required link speed and port count, whether you need fibre, and the operating temperature range.

エンジニアサポート

製品選定後のご相談

候補型番と、確認が必要な条件をお送りください。候補が明確になった後にサンプル支援を追加でき、商取引に関するご質問も同じ技術相談の中でご相談いただけます。

  1. 1選択した型番
  2. 2エンジニア確認
  3. 3サンプル申請
  4. 4商談

代替品評価をご希望の場合

  • 元の型番とデータシート

    資料のリビジョンも記載してください

  • 動作条件

    温度、絶縁電圧、PoE電流の条件

  • パッケージ制約

    ピン数、ピッチ、ピン列間隔

  • プロジェクト段階と年間数量

    サンプルと評価の優先度確認に使用します

  • 希望確認日

    候補と相違点の比較が必要な時期

エンジニア確認により候補型番を選び、相違点をご説明します。

サンプル・見積もりをご希望の場合

  • 候補型番

    選定表またはエンジニア確認で選んだ型番

  • 数量とプロジェクト段階

    試作/パイロット生産/量産

  • 希望納期

    サンプルと量産の時期を分けて記載してください

  • 必要資料

    適合資料、材料宣言、第三者機関レポートなど

サンプル数量、リードタイム、費用は、プロジェクト段階と型番によって異なります。営業担当者より営業日にご回答します。

お客様の情報は、このサポート依頼への回答にのみ使用します。

パラメータ比較

選択した型番を比較

相違点は確認用に表示しています。最終値と資料のリビジョンは、各型番のデータシートで確認してください。