The two figures govern different things: operating temperature is the ambient range allowed while the part is powered, storage temperature the range allowed while it is not.
The WH16603T1 is rated -40 °C to +105 °C operating and -40 °C to +85 °C in storage. The practical consequence is direct: the part may run to the higher figure, but warehousing, transport and long unpowered periods should stay within the storage range — the operating figure cannot be used to justify storage conditions. Where a project genuinely exceeds it, give VOOHU the actual conditions for confirmation.
Not in the electrical ratings but in what else is available at that height.
The WH16603T1 stands 2.50 mm Max, the same as the other low-profile parts, and its insertion loss, return loss, cross talk and common-mode rejection match the standard-height parts with no reduction. The real limit is that this height currently offers no high-isolation part and no PoE part: a design needing either has to move back to the standard height in the10/100 BASE-T range, and the clearance budget has to widen accordingly.
That it is characterised without bias: the WH16603T1 states OCL as 350 µH Min at 100 kHz and 0.1 V, with no DC bias term.
Parts that carry PoE capability normally add a bias current to that line, because port power puts a steady DC component on the centre tap and the inductance figure only means something under bias. The WH16603T1 is therefore not intended for ports powered through the centre tap — for PoE, choose a part in the10/100 BASE-T rangethat states a current capability explicitly.