WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers

Compare 120 W planar transformers for isolated active-clamp forward DC-DC designs. The four parts, WHPT-EQ200-023 through WHPT-EQ200-026, correspond to 3.3 V, 5 V, 12 V and 24 V output design options. The listed primary inductance is 280 μH minimum. Confirm topology and input/output conditions before choosing a part and requesting samples.

Für OEM- und Serienaufträge. MOQ: eine volle Rolle, ein volles Tray oder eine volle Stange pro Artikelnummer.

  • Eigene Werke: Steckverbinder in Dongguan, Magnetics in Mianyang
  • Über 1.500 Kunden, darunter mehr als 150 börsennotierte Unternehmen
  • Zertifiziert nach ISO 9001 und ISO 14001

Artikelsuche und Produktauswahl

Artikelnummern für WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers finden

Die Tabelle verwendet die aktuellen Produktdatensätze der englischsprachigen Website, veröffentlichte Auswahlfelder und artikelspezifische Links zu technischen Dateien.

* Spalten „Bild“ und „Artikelnummer“ fixiert · horizontal ziehen, um alle Spezifikationen anzuzeigen

Produktauswahlergebnisse für WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers
Bild Artikelnummer Datenblatt Vergleichen Downloads ModelPower(W)Inductance(μH)Lk(μH Max)ÜbersetzungsverhältnisIast(A)Output(V/A) Muster
VOOHU WHPT-EQ200-026 WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers WHPT-EQ200-026 SPEC WHPT-EQ200-120W Series1202800.51:1:0.5TBD24V/5A
VOOHU WHPT-EQ200-025 WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers WHPT-EQ200-025 SPEC WHPT-EQ200-120W Series1202800.51:0.5:0.5TBD12V/10A
VOOHU WHPT-EQ200-024 WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers WHPT-EQ200-024 SPEC WHPT-EQ200-120W Series1202800.51:0.25:0.5TBD5V/24A
VOOHU WHPT-EQ200-023 WHPT-EQ200 120 W Active-Clamp Forward Planar Transformers WHPT-EQ200-023 SPEC WHPT-EQ200-120W Series1202800.51:0.166:0.666TBD3.3V/36A

Schnellzugriff auf Produktfamilien

Mit der Produktfamilie beginnen

Die angegebenen Anzahlen basieren auf den aktuell veröffentlichten Produktdaten.

So wählen Sie aus

Auswahlhilfe für WHPT-EQ200 Planar Transformers: Select by Topology and Output

Auswahlschritte, Parametererläuterungen und der Serienvergleich für WHPT-EQ200 Planar Transformers: Select by Topology and Output stehen auf einer Seite. Bestätigen Sie dort die Serie und nutzen Sie dann diese Liste für Teilenummern, Dateien und Muster.

Auswahlhilfe für WHPT-EQ200 Planar Transformers: Select by Topology and Output öffnen →

Downloads und technische Ressourcen

Dateien nach Artikelnummer finden

Suchen Sie nach einer vollständigen oder teilweisen Artikelnummer und öffnen Sie anschließend das Datenblatt, das 3D-Modell oder den PCB-Footprint, ohne zur Produkttabelle zurückzukehren.

4
Aufgeführte PDF-Datenblätter
4
Aufgeführte 3D-Dateisätze
4
Aufgeführte PCB-Footprints

Die veröffentlichten Produktinhalte von VOOHU werden vom technischen Team geprüft. Spezifikationen, Downloads und Informationen zum technischen Support sind bestimmten Artikelnummern zugeordnet, sodass Sie sie vor einer Muster- oder Angebotsanfrage prüfen können.

FAQ und weiterführende Leitfäden

Fragen vor dem Design-in

Diese Antworten unterstützen den Ablauf auf der Seite. Artikelspezifische technische Grenzwerte ergeben sich weiterhin aus den verknüpften technischen Dateien.

Which topology is specified for the 120 W family?

The current datasheet specifies active-clamp forward, not universal LLC or arbitrary converter use. Check input voltage, frequency, duty cycle, winding connections and core-reset requirements against the controller reference design before sample validation.

Which 120 W part should I review for 24 V / 5 A?

WHPT-EQ200-026 lists 24 V / 5 A as a candidate for the corresponding active-clamp forward design. Also review input range, frequency, rectification and thermal design. The 120 W voltage/current product does not remove the need for operating-condition validation.

How should I compare inductance and leakage for the 120 W family?

The table lists 280 μH minimum and 0.5 μH maximum leakage. Preserve minimum, tolerance and maximum qualifiers, and compare at 100 kHz, 1 V with the specified connections. Measurement frequency is not necessarily the required converter switching frequency.

Can I fill the missing 90/120 W Isat value from a similar part?

No. The current 90/120 W tables do not give an Isat value. TBD does not mean zero, unlimited or the same as 60/71 W. If a limit is required, obtain engineering documentation appropriate to the topology, flux and operating conditions.

How do I request 120 W samples or replacement review?

For a selected part from WHPT-EQ200-023 to WHPT-EQ200-026, send the quantity and destination for pricing. For selection or replacement, provide input range, output voltage/current, the active-clamp forward controller and height limits. Sales will coordinate FAE matching.

Technischer Support

Nach der Produktauswahl fortfahren

Senden Sie die Artikelnummer des Kandidaten und die zu prüfende Bedingung. Muster können nach Abschluss der Auswahl angefragt werden; kaufmännische Fragen lassen sich im selben technischen Austausch klären.

  1. 1Ausgewählte Artikelnummern
  2. 2Technische Prüfung
  3. 3Musteranfrage
  4. 4Kaufmännische Abstimmung

Für eine Ersatztypenprüfung

  • Originalteil und Datenblatt

    Dokumentrevision angeben

  • Betriebsbedingungen

    Temperatur, Isolationsspannung und Bezugsgrundlage für den PoE-Strom

  • Gehäusevorgaben

    Pinzahl, Rastermaß und Abstand zwischen den Pinreihen

  • Projektphase und Jahresstückzahl

    Zur Priorisierung von Mustern und Evaluierung

  • Gewünschter Prüftermin

    Zeitpunkt, zu dem Sie Kandidaten und einen Vergleich der Unterschiede benötigen

Die technische Prüfung ermittelt geeignete Kandidaten und erläutert die Unterschiede.

Für Muster und ein Angebot

  • Kandidaten-Artikelnummern

    Aus der Produktauswahl oder technischen Prüfung

  • Menge und Projektphase

    Prototyp / Pilotserie / Serienfertigung

  • Benötigter Liefertermin

    Zeitplan für Muster und Serie getrennt angeben

  • Benötigte Unterlagen

    Konformitätsnachweise, Materialdeklarationen oder Berichte Dritter

Muster sind zur Evaluierung erhältlich, ausgewählte Typen kostenlos. Unser FAE-Team bestätigt Ihnen gern die Optionen für Ihr Projekt. Der Vertrieb antwortet an Werktagen.

Für OEM- und Serienaufträge. MOQ: eine volle Rolle, ein volles Tray oder eine volle Stange pro Artikelnummer.

Ihre Angaben werden ausschließlich zur Bearbeitung dieser Supportanfrage verwendet.

Veröffentlichte Ersatztypenprüfungen Alle Alternativen anzeigen

Parametervergleich

Ausgewählte Artikelnummern vergleichen

Die Unterschiede werden zur Prüfung dargestellt; bestätigen Sie die endgültigen Werte und Dateirevisionen im jeweiligen artikelspezifischen Datenblatt.