Signal line common mode chokes come in several chip sizes, and three common ones are 0805 (metric 2012, about 2.0 × 1.2 mm), 1210 (metric 3225, about 3.2 × 2.5 mm) and 1812 (metric 4532, about 4.5 × 3.2 mm). The size code fixes the footprint, but not the current rating or the impedance: those depend on the series and its winding, so a larger body does not automatically carry more current. To size a common mode choke, start from the impedance you need at your noise frequency, check rated current, DCR and voltage against the line, and then take the smallest package that meets those numbers and fits the layout. VOOHU offers signal line chokes in all three sizes, and the table below lists each datasheet's values together with the frequency at which impedance is specified.
[Product] WHAC-3225B-220U0
A chip size code gives length and width. The inch code counts hundredths of an inch, so 0805 means 0.08 × 0.05 in; the metric code counts tenths of a millimetre, so the same body is 2012, or 2.0 × 1.2 mm. Suppliers use either system, and some print both: the VOOHU WHAC-2012A datasheet states "Available in 2012(0805) Size". The usual pairs are below, with the body dimensions of the VOOHU parts compared later in this article.
| Inch code | Metric code | Nominal length × width | VOOHU body, L × W × H (mm, per datasheet) |
|---|---|---|---|
| 0805 | 2012 | 2.0 × 1.2 mm | 2.00 ±0.25 × 1.20 ±0.25 × 1.20 ±0.20 (WHAC-2012A) |
| 1210 | 3225 | 3.2 × 2.5 mm | 3.25 ±0.25 × 2.50 ±0.50 × 2.30 ±0.25 (WHAC-3225B-U0) |
| 1812 | 4532 | 4.5 × 3.2 mm | 4.50 ±0.25 × 3.20 ±0.25 × 2.30 ±0.25 (WHAC-4532A-U0) |
Two habits prevent most mix-ups. First, confirm which system a drawing or BOM uses: an inch 0603 is a metric 1608, while a metric 0603 is an inch 0201, a far smaller part. Second, read the tolerances, not just the code. The size code says nothing about height, and the WHAC-3225B-U0 drawing allows ±0.50 mm on width against ±0.25 mm on length, which matters when you place chokes side by side on parallel pairs or check them against a keep-out.
Body outlines of the three sizes at the same scale, top view. Illustration; dimensions per datasheet.
Treat the package as the last decision, not the first. Settle the electrical requirements and let the size follow:
Not by itself. The current rating comes from the wire, turns and core chosen for each series, and the VOOHU datasheets show it plainly:
So one 4532 body spans 150 mA to 3.0 A depending on the series. Choose from the values in the datasheet of the part, and treat the package as a layout decision. Moving up a size in the hope of gaining current margin only works if the larger part's datasheet actually gives a higher rating.
Because the test frequency is often different. The WHAC-2012A datasheets give common mode impedance at 100 MHz, while the WHAC-3225B-U0 and WHAC-4532A-U0 datasheets give it at 10 MHz. A 90 Ω figure at 100 MHz and a 1100 Ω figure at 10 MHz are points on different curves at different frequencies, and neither tells you which part suppresses more noise at your frequency. Put the curves side by side at the frequency from step 1. When you write your own requirement or a BOM note, keep the frequency with the number, for example "500 Ω min. at 10 MHz".
All values below come from each part's datasheet. Impedance is common mode impedance, and its test frequency has its own column, so compare impedance only within the same frequency.
| Size (inch / metric) | Part | Body L × W × H (mm) | Common mode impedance | Test frequency | DCR, max. | Rated current, max. | Rated voltage | Operating temperature | Datasheet notes |
|---|---|---|---|---|---|---|---|---|---|
| 0805 / 2012 | WHAC-2012A-900T0 | 2.00 × 1.20 × 1.20 | 90 Ω typ. | 100 MHz | 0.35 Ω | 300 mA | 50 Vdc | −40 °C to +125 °C | Withstanding voltage 125 Vdc |
| 0805 / 2012 | WHAC-2012A-801T0 | 2.00 × 1.20 × 1.20 | 800 Ω typ. | 100 MHz | 0.88 Ω | 300 mA | 50 Vdc | −40 °C to +125 °C | Withstanding voltage 125 Vdc; series offered from 90 Ω to 1200 Ω |
| 1210 / 3225 | WHAC-3225B-220U0 | 3.25 × 2.50 × 2.30 | 500 Ω min., 1100 Ω typ. | 10 MHz | 1.0 Ω | 250 mA | 80 V | −55 °C to +150 °C | 22 µH (+50/−30%); leakage inductance 70 nH typ.; datasheet lists CAN FD, CAN and A2B lines |
| 1210 / 3225 | WHAC-3225B-110U0 | 3.25 × 2.50 × 2.30 | 300 Ω min., 550 Ω typ. | 10 MHz | 0.8 Ω | 300 mA | 80 V | −55 °C to +150 °C | 11 µH; leakage inductance 50 nH typ.; same series as above |
| 1812 / 4532 | WHAC-4532A-220U0 | 4.50 × 3.20 × 2.30 | 500 Ω min., 1200 Ω typ. | 10 MHz | 1.4 Ω | 200 mA | See datasheet | −55 °C to +150 °C | Datasheet lists CAN FD, CAN and A2B lines |
Body tolerances are listed in the size table above.
How to use the table. Where board space is tight and you need impedance around 100 MHz, start with the WHAC-2012A-900T0 (90 Ω) or the WHAC-2012A-801T0 (800 Ω) in 0805. For CAN FD, CAN or A2B lines, the WHAC-3225B-220U0 is a 1210 option whose datasheet names those interfaces; the WHAC-3225B-110U0 trades impedance for a 300 mA rating and lower DCR. Choose the WHAC-4532A-220U0 when your layout already has an 1812 footprint that you want to keep, and you need the same 500 Ω minimum class at 10 MHz; check the land pattern against its datasheet first.
To compare more parts, open the signal line common mode choke selector and filter by size (1210 / 3225 or 1812 / 4532), or browse the WHAC2012A, WHAC3225B and WHAC4532A series pages. For how signal line and power line chokes differ, read signal and power line common mode chokes.
Only after checking it. Two chokes with the same size code can differ in pad size, pin numbering and winding orientation, and a choke placed with one winding reversed puts its high impedance on your signal instead of on the noise. Use the recommended land pattern from the datasheet of the exact part: the WHAC-2012A, WHAC-3225B-U0 and WHAC-4532A-U0 datasheets each give one with the dimension drawing, together with a winding schematic. Before the first build, check pin 1 and the schematic against your footprint and against which line of the pair goes to which winding. If one footprint must accept parts from two suppliers, compare both drawings pad by pad and fit samples of both. For USB 2.0 pairs, see how to choose a USB 2.0 common mode choke.
Q1: What are the dimensions of an 0805 common mode choke?
An 0805 chip is nominally 2.0 × 1.2 mm, which is metric size 2012. Height is not part of the code and varies by series: the VOOHU WHAC-2012A body is 2.00 ±0.25 × 1.20 ±0.25 mm and 1.20 ±0.20 mm high, and its datasheet describes the size as 2012(0805). Take the height and pad dimensions from the datasheet of the part you will place, not from a generic 0805 library footprint.
Q2: Is a 1210 common mode choke the same as a 3225?
Yes. 1210 is the inch code and 3225 the metric code for a body of about 3.2 × 2.5 mm, just as 1812 corresponds to 4532, about 4.5 × 3.2 mm. The code does not fix tolerances or height, so two 3225 chokes can still differ; the VOOHU WHAC-3225B-U0, for example, is 3.25 ±0.25 × 2.50 ±0.50 × 2.30 ±0.25 mm.
Q3: How can I determine the specs of a common mode choke on an existing board?
Start with what you can measure. Measure the body to get the size code, note any marking, and measure the DC resistance of each winding. For common mode impedance, connect the two input pins together and the two output pins together, then measure between those two points with an impedance analyzer across your frequency range; that gives you the curve to match. Compare the curve and DCR with candidate datasheets at your noise frequency, and confirm the choice with samples on the board. You can send those measurements to our FAE team, who can suggest candidate parts.
Q4: How should chip common mode chokes be stored and reflowed?
Follow the datasheet of the exact part. The VOOHU WHAC-2012A, WHAC-3225B-U0 and WHAC-4532A-U0 datasheets each include a recommended reflow profile. The WHAC-4532A-U0 datasheet also asks for components to be preheated so that the difference between solder temperature and chip temperature does not exceed 150 °C, and for storage sealed in packaging at 5 °C to 40 °C and 10% to 75% RH or less, with any parts left after opening resealed in plastic bags to protect the electrodes.
Q5: When should I use a common mode choke instead of a ferrite bead?
Use a common mode choke on a differential pair, or any pair of lines whose noise flows the same way on both, because the choke blocks that noise while passing the signal. A ferrite bead on a single line acts on the signal and the noise alike within its frequency range, so it suits single-ended lines and supply rails. See ferrite bead vs common mode choke for when each is enough, what is a common mode choke for how the windings work, and common mode vs differential mode noise for which filter treats which noise.
Tell us the interface, the noise frequency you need to suppress, the current on the line and the space you have on the board through our sample request form. Our FAE team can suggest suitable parts and help check the design, from impedance at your frequency to the land pattern and pin 1 orientation of the package you choose. Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. VOOHU manufactures these common mode chokes and makes its magnetics in its own factory in Mianyang. VOOHU supplies RJ45 and SFP connectors, LAN and PoE transformers and common mode chokes from Suzhou, China, to more than 1,500 customers.
WHAC-3225B-220U0 Inductance22uH RDC1Ω Leakage Inductance70nH Common Mode Chokes
> View Details
WHAC-2012A-900T0 RDC0.35 (Ω) Maximum rated current 300mA Maximum rated voltage 50(V) Common mode inductor for signal lines
> View Details
WHAC-4532A-220U0 Inductor 22uH RDC1.4Ω Typical leakage inductance 80nH Isolation resistance 10MΩ Common mode inductor
> View Details