Skip to main content
VOOHU Cat7 RJ45 Couplers products

I/O Connector products

Cat7 RJ45 Couplers

Cat7 cable is individually screened per pair as well as overall, so the join has to preserve that screening to be worth specifying. Confirm what connector interface the installation uses, because Cat7 cable is sometimes terminated to other standards.

Part number search & selector

Find Cat7 RJ45 Couplers part numbers

The table uses the current English-site product records, published selection fields and part-specific technical-file links.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

Cat7 RJ45 Couplers product selection results
Image Part number Datasheet Compare Downloads Network LevelTransmission BandwidthShieldGold plating of contactsPanel Sample
VOOHU WHZJT020242 Cat7 RJ45 Couplers WHZJT020242 SPEC Cat6250MHzNO-YES
VOOHU SYTUS030026SL Cat7 RJ45 Couplers SYTUS030026SL SPEC Cat6250MHzNO50UNO
VOOHU WHKNZ63YSCAT6a Cat7 RJ45 Couplers WHKNZ63YSCAT6a SPEC Cat6250MHz—3UYES
VOOHU WHKNZ63CAT6a180 Cat7 RJ45 Couplers WHKNZ63CAT6a180 SPEC Cat6250MHz—3UYES
VOOHU WHZJT020295 Cat7 RJ45 Couplers WHZJT020295 SPEC Cat6250MHzYES6UYES
VOOHU SYTZT1188IWA17DY3S2T5E387A Cat7 RJ45 Couplers SYTZT1188IWA17DY3S2T5E387A SPEC Cat5e100MHzNO3UYES
VOOHU SYTZT1188IWA17B3HT6387 Cat7 RJ45 Couplers SYTZT1188IWA17B3HT6387 SPEC Cat6250MHzNO3UNO
VOOHU SYT-US030-015E Cat7 RJ45 Couplers SYT-US030-015E SPEC Cat6250MHzYES6UNO
VOOHU SYT-PCB003 Cat7 RJ45 Couplers SYT-PCB003 SPEC --YES50UNO
VOOHU WHZT3811EK0042P8111059 Cat7 RJ45 Couplers WHZT3811EK0042P8111059 SPEC Cat316MHzYES6UNO
VOOHU SYTZT1188GWC8D3T5E387 Cat7 RJ45 Couplers SYTZT1188GWC8D3T5E387 SPEC Cat5e100MHzYES6UNO
VOOHU SYT5866ZT1188GWA12D3T6387 Cat7 RJ45 Couplers SYT5866ZT1188GWA12D3T6387 SPEC Cat6250MHzNO-YES
VOOHU SYTZT1188IWA17DY3S2T6387 Cat7 RJ45 Couplers SYTZT1188IWA17DY3S2T6387 SPEC Cat6250MHzNO3UYES
VOOHU RJ45-8P8C Cat7 RJ45 Couplers RJ45-8P8C SPEC --YES-NO
VOOHU SYT-PCB007 Cat7 RJ45 Couplers SYT-PCB007 SPEC --YES6UNO
VOOHU SYTZT1188GWC9DY3S4T6387 Cat7 RJ45 Couplers SYTZT1188GWC9DY3S4T6387 SPEC Cat6250MHzYES-YES
VOOHU SYTZT1188GWC9DY3S2T6387 Cat7 RJ45 Couplers SYTZT1188GWC9DY3S2T6387 SPEC Cat6250MHzYES-YES
VOOHU SYT-US030-026E-L Cat7 RJ45 Couplers SYT-US030-026E-L SPEC Cat6250MHzYES50UNO
VOOHU WHS5960 Cat7 RJ45 Couplers WHS5960 SPEC --YES-NO

How to select

A practical selection sequence

Narrow the published fields in sequence, compare the remaining candidates and verify the part-specific files before design-in.

  1. 01

    Confirm straight-through or special wiring

    Specify both interfaces, gender and contact mapping; assess any one-to-two adapter separately.

  2. 02

    Match the cabling category

    Choose documented Cat5e or Cat6 candidates for the channel; missing fields are not a pass.

  3. 03

    Choose shielding and mounting

    Review shield grounding, panel retention, cutout and cable clearance.

  4. 04

    Validate the channel and request supply

    Test at the intended length, data rate and power conditions, then send the part number, quantity and timing for a quote.

Key selection parameters

What each filter helps you decide

01

Performance category

Confirm Cat5e/Cat6 in the part specification rather than inferring an absent category from its name.

02

Frequency bandwidth

MHz describes frequency, not achieved data rate in Mb/s.

03

Shielding

Review shield continuity and grounding across the coupler, cables and equipment.

04

Panel mounting

Check clips/fasteners, cutout, panel thickness and access on both sides.

05

Contacts and wiring

Verify plating location and units and contact mapping; a one-to-two adapter is not an ordinary inline coupler.

Product family comparison

Compare the published Network Level

Use this summary as a routing step, then verify every required value in the exact part-number row and linked technical files.

Return to the selector ↑
Network LevelPartsTransmission BandwidthShieldGold plating of contactsPanelAction
Cat3116MHzYES6UNOFilter →
Cat5e2100MHzYES, NO3U, 6UYES, NOFilter →
Cat612250MHzYES, NO, Not specified3U, 6U, 50U, -YES, NOFilter →
-4-YES6U, 50U, -NOFilter →

Technical performance & application fit

Validate the complete design context

Application suitability is part-number specific. Treat the catalog fields as a shortlist, then confirm the design against the linked technical files.

Application review

Equipment panel feedthroughs

  • Check panel retention and mating clearance when connecting internal and external cables.
Application review

Equipment cable connection and service

  • Confirm wiring and category and reassess the complete channel after adding a connection.
Get technical support →

Downloads & technical resources

Find files by part number

Search a full or partial SKU, then open its datasheet, 3D model or PCB footprint without returning to the product table.

0
PDF datasheets listed
0
3D file sets listed
0
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Category overview

What an inline coupler does to the link

Couplers are simple parts, but two questions come up constantly: whether they slow the link, and which category to use.

01

It joins two runs without re-terminating

A coupler mates two RJ45 plugs back to back, so two existing cable runs become one channel without cutting and re-terminating either end. That is its whole purpose: extending or repairing a run with existing patch leads rather than making up a new cable.

02

Does it slow the connection

Not in the sense people usually mean. A coupler does not reduce the negotiated link speed. It adds a connection point, which introduces an impedance discontinuity and a small insertion loss. On a short gigabit run that sits inside the margin. Near the length limit, or at 10G, it consumes margin already thin.

03

Match the category to the channel

The channel performs to its weakest element, so a Cat5e coupler caps a Cat6A channel at Cat5e. Use a coupler at or above the category of the cable and the link. On screened installations, use a shielded coupler so the screen stays continuous through the join, or the shielding is defeated at that point.

FAQ & related guides

Questions before design-in

These answers guide the page workflow. Part-specific engineering limits still come from the linked technical files.

What does Cat7 add over Cat6A?

Cat7 cable screens each pair individually as well as overall, giving better crosstalk performance at high frequency. For that to mean anything, the connections must preserve the screening. A coupler that does not maintain screen continuity undoes the reason for choosing Cat7 cable.

Is Cat7 an RJ45 standard?

Cat7 cable is often terminated to connector interfaces other than RJ45 in its original specification, though RJ45 compatible hardware is widely used in practice. Confirm what interface the installation actually uses before ordering, because assuming RJ45 throughout can cause a mismatch on site.

Do I need shielded couplers throughout?

On a screened installation, yes. Every connection point has to carry the screen through, or the shielding becomes discontinuous and its benefit is lost at that point. Mixing shielded cable with unshielded joins is a common and avoidable installation error.

Does a higher category always give a better link?

Only if the whole channel matches. The link performs to its weakest element, so a Cat7 coupler on Cat5e cable gives Cat5e performance. Specify the category from the requirement, then apply it consistently to cable, connectors and couplers.

How do I request samples or a quote?

With a complete part number, send the part number, quantity, delivery region and the date you need it. If you are still selecting, send the cable type, the connector interface used on site and the required link speed.

Engineer support

Continue after product selection

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are free of charge. Sample quantity and lead time depend on the part number and project stage. Sales will respond on business days.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.