Skip to main content
VOOHU QSFP28 Connectors, Cages & Assemblies products

I/O Connector products

QSFP28 Connectors, Cages & Assemblies

Select a QSFP28 PCB receptacle, cage or cage-and-connector assembly. Compare single-port, ganged and stacked layouts, then review panel fit, PCB mounting, light pipes and thermal requirements. Confirm supplied content for the selected part.

Part number search & selector

Find QSFP28 Connectors, Cages & Assemblies part numbers

Filter QSFP28 connectors and cages by type, mounting, ports, light pipe, heat dissipation and plating.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

QSFP28 Connectors, Cages & Assemblies product selection results
Image Part number Datasheet Compare Downloads Pluggable I/O product typeOverall dimensionsData Rate (Max) (Gb/s)Installation TypePortsIncluded LightpipeHeat dissipationConnector Gold PlatedNickel Plated Shell Sample
VOOHU WH591H009D1S20 QSFP28 Connectors, Cages & Assemblies WH591H009D1S20 SPEC CageQSFP28100GPress-Fit1 x 1○○○○Heat SinkNoneNi 30U
VOOHU WH81161Y00171 QSFP28 Connectors, Cages & Assemblies WH81161Y00171 SPEC CageQSFP28100GPress-Fit1 x 1NONEHeat SinkNoneNi 30U
VOOHU WHSFP36111W040 QSFP28 Connectors, Cages & Assemblies WHSFP36111W040 SPEC CageQSFP28100GSolder1 x 1NONEHeat SinkNoneNone
VOOHU WHSFP36814W002 QSFP28 Connectors, Cages & Assemblies WHSFP36814W002 SPEC CageQSFP28100GPress-Fit1 x 4NONEHeat SinkNoneNone
VOOHU WH81161Y21211 QSFP28 Connectors, Cages & Assemblies WH81161Y21211 SPEC CageQSFP28100GPress-Fit2 x 1△ ▽Heat Sink30U—
VOOHU WHSFP38422F020 QSFP28 Connectors, Cages & Assemblies WHSFP38422F020 SPEC Cage+ConnectorQSFP28100GPress-Fit2 x 2△ ▽Heat dissipation holesNoneNone
VOOHU WHSFP38221F014 QSFP28 Connectors, Cages & Assemblies WHSFP38221F014 SPEC Cage+ConnectorQSFP28100GPress-Fit2 x 1△ ▽Heat dissipation holesNoneNone
VOOHU WHSFP35111D010 QSFP28 Connectors, Cages & Assemblies WHSFP35111D010 SPEC ConnectorQSFP28100G—1 x 1NONE—NoneNone
VOOHU WHSFP36714W021 QSFP28 Connectors, Cages & Assemblies WHSFP36714W021 SPEC CageQSFP28100GPress-Fit1 x 4NONE—NoneNone
VOOHU WHSFP161C00021 QSFP28 Connectors, Cages & Assemblies WHSFP161C00021 SPEC ConnectorQSFP28100G—1 x 1NONE—NoneNone

Series overview

Selecting a QSFP28 connector, cage or assembly

A QSFP28 connector sits on the host board under a shielding cage, forming a 100G pluggable port at the front panel. You may also see QSFP28 cage, 100G QSFP28 cage or QSFP28 cage assembly. The range covers press-fit and solder cages, 1 x 4 ganged cages, 2 x 1 and 2 x 2 stacked versions and PCB connectors; many cages carry a heat sink. For 40G, see QSFP and QSFP+ connectors; for 200G, see QSFP56 connectors and assemblies.

01

Heat sink cages for 100G

Most cages here carry a heat sink, for example the press-fit WH81161Y00171 (1 x 1), the solder-mount WHSFP36111W040 (1 x 1) and the ganged WHSFP36814W002 (1 x 4). Check the added height against the lid.

02

Ganged 1 x 4 cages

Four ports side by side fit one ganged cage. WHSFP36814W002 adds a heat sink; WHSFP36714W021 lists no heat dissipation feature, so read its drawing. Place a PCB connector under each port as the drawing shows.

03

Stacked ports with light pipes

WHSFP38221F014 (2 x 1) and WHSFP38422F020 (2 x 2) are cage-and-connector assemblies with light pipes and heat dissipation holes. WH81161Y21211 is a 2 x 1 cage with light pipes and a heat sink.

04

PCB connectors on their own

Where cage and connector are bought separately, the QSFP28 PCB connectors WHSFP35111D010 and WHSFP161C00021 are listed; take plating and mounting from their datasheets and confirm the pairing in both drawings.

Open the SFP Connectors & Cages selection guide →

Applications

Where QSFP28 connectors and cages go

QSFP28 is a common 100G pluggable format.

Data center

100G spine and leaf switches

Switch line cards with many 100G ports use stacked and ganged parts, such as the 2 x 2 assembly WHSFP38422F020 or the 1 x 4 heat sink cage WHSFP36814W002, to keep port pitch tight.

Servers

SmartNICs and accelerator cards

Adapter cards usually expose one or two ports at the bracket. A single-port heat sink cage such as WH81161Y00171, or WH591H009D1S20 with light pipes, suits them; check height against the bracket.

Telecom

Routers and optical transport

Edge routers and transport shelves use 100G client ports, where 2 x 1 stacks such as WHSFP38221F014 or WH81161Y21211 save faceplate width. Their light pipes show port status on a dense faceplate.

Downloads & technical resources

QSFP28 connector datasheets and 3D models

Search a part number for its datasheet and, where listed, the 3D model; check port pitch, cage height and press-fit holes before layout.

10
PDF datasheets listed
4
3D file sets listed
0
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Sourcing

QSFP28 connector purchasing and support

VOOHU is a QSFP28 connector manufacturer, with its own connector factory in Dongguan. Each part has a datasheet, and some cages add a 3D model for checking fit at the panel before samples or a quotation.

01

Samples and quotations

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. For a quote, include part numbers, quantity and target ship date; typical lead time is 7–10 days.

02

Replacing an existing QSFP28 cage

Send the part number and datasheet of the QSFP28 part you use today. Our FAE team compares port layout, cooling, light pipes, press-fit pattern and footprint, then proposes VOOHU candidates to validate with samples before production.

03

Quality and company

VOOHU is ISO 9001 and ISO 14001 certified. Since 2018 VOOHU has supplied more than 1,500 customers, including 150+ listed companies.

FAQ & related guides

Answers on QSFP28 connectors

Questions on manufacturing, cooling and the QSFP-DD format.

Does a QSFP28 cage include the PCB receptacle?

A standalone cage and an integrated assembly are different items. The English catalog lists cages, PCB receptacles and cage-and-connector assemblies. Check the component type and supplied content for the ordered part.

Can 1×1 and 2×1 cages share a panel design?

Check the cutout, port spacing, height and retention separately; do not assume the same panel design.

How do I check a QSFP28 light-pipe option?

Confirm quantity, position, LED alignment and inclusion. Request a drawing if the catalog uses undefined symbols.

Does a QSFP28 cage guarantee a 100G link?

No. The cage is a mechanical and shielding component. The link also depends on the receptacle, module, PCB and system validation.

How do I submit a QSFP28 cage sourcing request?

Send the part, layout, receptacle pairing, heat-sink/light-pipe needs, sample or production quantity and timing.

Who manufactures these QSFP28 connectors?

VOOHU does. The connectors, cages and assemblies on this page are made in VOOHU’s own connector factory in Dongguan, China, alongside the SFP28 and QSFP-DD ranges, so 25G, 100G and 400G ports can share one supplier.

Do I need a QSFP28 cage with heat sink?

It depends on module power, airflow and enclosure temperature. Cages such as WH81161Y00171 and WHSFP36814W002 carry one, while WHSFP38221F014 relies on heat dissipation holes. Run a thermal test with the planned modules and check the cage height in the drawing.

How does a QSFP28 cage differ from a QSFP-DD cage?

QSFP-DD is the double-density member of the family, listed for 400G on our QSFP-DD connector and cage page, while parts here are listed for 100G. Select each against its own drawings; do not assume one outline fits the other.

Engineer support

QSFP28 connector samples and engineering review

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.