D12 refers to the nominal twelve millimetre disc diameter. It suits boards where a larger disc will not fit, at the cost of energy handling. Confirm the varistor voltage against worst-case line conditions and check the clamping figure at your real surge current.

Part number search & selector

Find D12 Metal Oxide Varistors part numbers

The table uses the current English-site product records, published selection fields and part-specific technical-file links.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

D12 Metal Oxide Varistors product selection results
Image Part number Datasheet Compare Downloads Tolerance Voltage (DC.V)Clamping Voltage/VRated Power/WPackageOperating Temperature Sample
VOOHU WHM0082VA D12 Metal Oxide Varistors WHM0082VA SPEC 651350.1D14-40 °C to 125 °C

By disc size

Choose a varistor by disc diameter

Disc diameter broadly tracks energy handling, but the datasheet figures decide.

How to select

Selection guide for Metal Oxide Varistors (MOV)

Selection steps, parameter explanations and the series comparison for Metal Oxide Varistors (MOV) are on one page. Confirm the series there, then use this list for part numbers, files and samples.

Open the Metal Oxide Varistors (MOV) selection guide →

Documents

Varistor datasheets and drawings

Datasheets carry the voltage window, clamping figures and surge waveform conditions.

0
PDF datasheets listed
0
3D file sets listed
0
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

FAQ

Metal oxide varistor questions engineers ask

Answers cover how a varistor works, ageing, failure modes and coordination.

What does D12 refer to?

The nominal disc diameter of the ceramic body, about twelve millimetres. It is a mechanical classification used to filter by size and footprint. The actual dimensions, lead spacing and recommended mounting come from the datasheet for the specific part, not from the size code alone.

How much energy will a D12 part absorb?

Less than a larger disc of the same voltage class, because absorption scales with the volume of ceramic available to take the heat. How much less depends on the specific part, so compare the rated surge current and energy figures at the same waveform rather than inferring from diameter.

When should I move up from D12?

When the surge class the installation must meet exceeds what a D12 part is rated for, or when the derating curve shows the part will not survive the expected number of events over its service life. Check the board has room for the larger disc and lead spacing before changing.

Does a smaller disc clamp differently?

Clamping voltage depends mainly on the voltage class rather than the diameter, so two parts of the same class clamp at broadly similar levels. What changes with size is how much energy the part can take before it degrades. Compare the clamping figure at your actual surge current.

How do I request samples or a quote?

With a complete part number, send the part number, quantity, delivery region and the date you need it. If you are still selecting, send the line voltage and type, the surge standard you must meet and the available board space, and a sales engineer will confirm candidates.

Engineer support

Continue after product selection

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are free of charge. Sample quantity and lead time depend on the part number and project stage. Sales will respond on business days.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.