Output rails
ST1001WH, ST1007WH and ST1008WH are listed for 12 V, and ST1006WH, ST1009WH, ST1010WH, ST1011WH and ST1013WH for 13.5 V. ST0880WH, WH10P-50L and WH10P-50L2 cover 5 V. Treat each rail as a separate winding design.
Transformer products
Find EP10 candidates against your DC-DC power-stage requirements. Along with the target output, check the input range at the transformer stage, controller, main windings and auxiliary-supply needs. Compare part documents before sample validation. If the part is already identified, request samples or pricing directly.
Part number search & selector
Filter EP10 PoE transformers by package size, power, output voltage and output current.
* Frozen Image and Part Number columns · drag horizontally to review all specifications
| Image | Part number | Datasheet | Compare | Downloads | Package Size | Power (W) | Output Voltage (V) | Output Current (A) | Sample |
|---|---|---|---|---|---|---|---|---|---|
|
ST0880WH | SPEC | EP10 Series | 12W | 5V | ≥ 2A |
|
||
|
WH10P-50L2 | SPEC | EP10 Series | 10W | 5V | ≥ 2A |
|
||
|
WH10P-50L | SPEC | EP10 Series | 10W | 5V | ≥ 2A |
|
||
|
ST1013WH | SPEC | EP10 Series | 10W | 13.5V | 0.41A~1.0A |
|
||
|
ST1011WH | SPEC | EP10 Series | 12W | 13.5V | 0.41A~1.0A |
|
||
|
ST1010WH | SPEC | EP10 Series | 12W | 13.5V | 0.41A~1.0A |
|
||
|
ST1009WH | SPEC | EP10 Series | 12W | 13.5V | 0.41A~1.0A |
|
||
|
ST1008WH | SPEC | EP10 Series | 5W | 12V | 0.41A~1.0A |
|
||
|
ST1007WH | SPEC | EP10 Series | 6W | 12V | 0.41A~1.0A |
|
||
|
ST1006WH | SPEC | EP10 Series | 12W | 13.5V | 0.41A~1.0A |
|
||
|
ST1001WH | SPEC | EP10 Series | 7W | 12V | 0.41A~1.0A |
|
Broaden the selected filters or clear the current search.
Product family quick links
Counts reflect the current published product data.
Series overview
An EP10 PoE transformer is the power transformer of the isolated DC-DC stage in a PoE powered device, between the PD interface and the load rail. It is also listed as an EP10 PoE power transformer or DC-DC transformer. Parts here run from 5 W to 12 W with 5 V, 12 V or 13.5 V outputs. For 3 W or 15 W see EP7 PoE transformers, and for up to 30 W EP13 PoE transformers.
ST1001WH, ST1007WH and ST1008WH are listed for 12 V, and ST1006WH, ST1009WH, ST1010WH, ST1011WH and ST1013WH for 13.5 V. ST0880WH, WH10P-50L and WH10P-50L2 cover 5 V. Treat each rail as a separate winding design.
The 12 V parts sit at the low end: ST1008WH at 5 W, ST1007WH at 6 W and ST1001WH at 7 W. ST1013WH, WH10P-50L and WH10P-50L2 are listed at 10 W, and ST0880WH and the other 13.5 V parts at 12 W.
ST0880WH, WH10P-50L and WH10P-50L2 are listed at ≥ 2 A. The 12 V and 13.5 V parts fall in the 0.41–1.0 A band. Read them as filters and confirm current and temperature rise on the datasheet.
The controller often runs from an auxiliary winding on the transformer. When comparing EP10 parts, check whether the datasheet shows one, which side it sits on and the supply your controller needs from it.
Applications
EP10 parts serve powered devices that need 5 W to 12 W from the converter.
Desk phones, intercoms and door stations often need only modest 12 V power. ST1008WH (5 W), ST1007WH (6 W) and ST1001WH (7 W) are the low-power 12 V candidates here.
Where a camera or access point design calls for 13.5 V, ST1013WH is listed at 10 W and ST1006WH, ST1009WH, ST1010WH and ST1011WH at 12 W, each in the 0.41–1.0 A band.
Boards that power USB ports or 5 V controllers need current headroom on the 5 V rail. ST0880WH (12 W) and WH10P-50L or WH10P-50L2 (10 W) are listed for 5 V at ≥ 2 A.
Downloads & technical resources
Enter a part number for the EP10 transformer datasheet, 3D model and PCB footprint; check windings, auxiliary supply and pins before layout.
Showing representative available file sets. Search to find a specific SKU.
VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.
Sourcing
VOOHU manufactures these parts in its own magnetics factory in Mianyang. Datasheets, 3D models and PCB footprints are published for the EP10 PoE transformers on this page for review before you request samples.
Discuss a new design
Contact FAE for a replacement assessment.
Already have a part number? Request samples or a quote.
Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Send part numbers and quantities for a quotation; typical lead time is 7–10 days.
If your design uses another supplier’s PoE transformer, send its part number and datasheet. Our FAE team checks the output rail, power, windings and footprint, then proposes EP10 alternatives to validate with samples before production.
VOOHU is ISO 9001 and ISO 14001 certified, and its PoE transformers are RoHS and REACH compliant (third-party test reports). Since 2018 VOOHU has supplied more than 1,500 customers, including 150+ listed companies.
FAQ & related guides
Answers on manufacturing, the 5 V parts and how EP10 differs from a LAN transformer.
These are different selector directions, not an interchangeability statement. Define the actual rail and its tolerance, then compare windings, rectification and feedback requirements. Assess parts such as ST1008WH and ST1010WH against their own complete documents; a common family does not establish identical output capability.
The A0 winding diagram places AUX on the primary side at pins 3 and 4, with the main secondary on the opposite side at pins 7 and 5. Do not confuse their roles. State any controller auxiliary-supply voltage and current requirements for FAE review rather than assuming an additional output rail.
No. The 115 μH±10% inductance is measured at 100 kHz, 1 V and 25°C; the leakage measurement also requires the specified shorting of other pins. Switching frequency comes from the control design. Review input, operating mode and temperature rise rather than inferring suitability from a measurement frequency.
Start with the complete part number and revision. Compare input conditions, windings, auxiliary supply, measurement references and pins. Share the original documents and circuit through your sales engineer for FAE matching. Equal selector labels still require a circuit review and sample validation.
The family name alone does not establish that. Identify the existing limitation, such as temperature rise, winding loss, space or controller constraints, then compare the actual candidates. A package change may also require land-pattern and pin changes. Your sales engineer can coordinate an FAE comparison rather than treating the series number as a power rating.
VOOHU does. These EP10 PoE transformers are manufactured in VOOHU’s own magnetics factory in Mianyang, China, and each part number comes with a datasheet, 3D model and PCB footprint. Samples can be requested from this page.
ST0880WH is listed for 5 V at 12 W, and WH10P-50L and WH10P-50L2 for 5 V at 10 W, each in the ≥ 2 A band. WH10P-50L and WH10P-50L2 share the same selector values, so compare their datasheets for winding and pin differences.
No. The EP10 PoE transformer sits in the DC-DC converter and makes the supply rail. The LAN transformer at the RJ45 port passes the data pairs and carries PoE current through its center taps. A PoE device needs both; see LAN transformers for the data side.
Engineer support
Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.
Include the document revision
Temperature, isolation voltage and PoE current basis
Pin count, pitch and spacing between pin rows
To help prioritize samples and evaluation
When you need candidates and a comparison of differences
Engineering review identifies candidate parts and explains the differences.
From the selector or engineering review
Prototyping / pilot build / production
Specify sample and production timing separately
Compliance documents, material declarations or third-party reports
Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.