Skip to main content
VOOHU WHST06Q Push-Pull Transformer products

Transformers

WHST06Q Push-Pull Transformer

Check the winding arrangement against your power-supply requirements. The WHST06Q family currently lists WHST06Q02E0, with 86 μH minimum inductance, a 1CT:2.88CT turns ratio and specified 2500 VAC dielectric test conditions. Review design files or send your requirements or existing part number for sales and FAE support.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

  • Own factories: connectors in Dongguan, magnetics in Mianyang
  • 1,500+ customers, including 150+ listed companies
  • ISO 9001 and ISO 14001 certified
  • Certificates and test reports →

Part number search & selector

Find WHST06Q Push-Pull Transformer part numbers

Filter WHST06Q push-pull transformers by inductance, turns ratio, winding DCR, isolation and temperature.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

WHST06Q Push-Pull Transformer product selection results
Image Part number Datasheet Compare Downloads SeriesL(μH)Turns RatioDCR1(mΩ)DCR2(mΩ)Isolation(VAC)Operating Temperature(℃) Sample
VOOHU WHST06Q06A0 WHST06Q Push-Pull Transformer WHST06Q06A0 SPEC WHST06Q3501:1.24005204000-40℃ to 125℃
VOOHU WHST06Q02E0 WHST06Q Push-Pull Transformer WHST06Q02E0 SPEC WHST06Q861:2.881005002500-40℃ to 125℃

Series overview

About the WHST06Q push-pull transformer

The WHST06Q push-pull transformer, WHST06Q02E0, is a low-inductance, low-DCR step-up part for compact isolated DC-DC supplies. It is also searched as a push-pull isolation transformer or DC-DC isolation transformer. At 86 μH it sits below the inductance of the other WHST push-pull families, which points to a higher switching frequency. For step-up parts with 4,000 VAC isolation, compare WHST06K push-pull transformers.

01

Step-up ratio

WHST06Q02E0 lists 1:2.88, a step-up for isolated rails above the input, with center taps on both windings for full-wave rectification.

02

Low inductance

Magnetizing current rises with on-time over inductance, so at 86 μH the driver must switch fast; compare your frequency and duty cycle with the datasheet conditions.

03

Low primary DCR

Primary DCR is 100 mΩ and secondary DCR 500 mΩ; the primary carries the larger current in a step-up design, so low resistance there keeps loss down.

04

Isolation and temperature

WHST06Q02E0 lists 2,500 VAC isolation and −40 °C to +125 °C operation. The isolation is a test value, and the wide range is not automotive qualification.

Open the Push-Pull Transformers selection guide →

Applications

Where the WHST06Q push-pull transformer fits

Its step-up ratio and low inductance suit small, fast-switching supplies.

Compact boards

Small isolated step-up rails

Boards short of space can use WHST06Q02E0 to raise a low input to a higher isolated bias supply, sizing rectifier and LDO from 1:2.88 and the load.

Measurement

Amplifier and sensor rails

Isolated amplifiers and sensor front ends often need an isolated power supply above the logic rail; one step-up stage can provide it.

Industrial

Fieldbus and I/O isolation

Isolated CAN, digital I/O and communication modules use small push-pull stages for the field-side supply, which WHST06Q02E0 can raise well above the input.

Downloads & technical resources

WHST06Q push-pull transformer datasheet and models

Search WHST06Q02E0 for its push-pull transformer datasheet, 3D model and PCB footprint, then check pin assignment and polarity.

2
PDF datasheets listed
2
3D file sets listed
2
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Sourcing

Buying the WHST06Q push-pull transformer

VOOHU manufactures the WHST06Q push-pull transformer in its own magnetics factory in Mianyang. WHST06Q02E0 has a datasheet, 3D model and PCB footprint for fit and pin checks before samples.

01

Samples and a quote

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. For a quotation, send quantity and target date; typical lead time is 7–10 days.

02

Alternative for an existing part

Name the transformer you want to replace and attach its datasheet; our FAE team weighs ratio, inductance, DCR, isolation and footprint against VOOHU parts, and you validate the candidate with samples before production.

03

Quality

VOOHU is ISO 9001 and ISO 14001 certified. Since 2018 VOOHU has supplied more than 1,500 customers, including 150+ listed companies.

FAQ & related guides

What to know about the WHST06Q push-pull transformer

Manufacturing, drive frequency and alternatives.

Does WHST06Q offer several parts to compare?

The current selector lists one part, WHST06Q02E0. This page supports checks of its winding arrangement, specifications and layout; it does not imply multiple interchangeable variants. For a different ratio or package, compare the main selector or submit your power requirements for sales and FAE review.

Does the 5 V input and 12 V output example define a fixed output?

No. The datasheet lists 5 V input, 12 V output, 460 mA and 400 kHz as typical application conditions and notes that results vary by application. This is not a regulated power-module guarantee. Provide the driver circuit, rectification and load for FAE review and sample validation.

How should I use the 1:2.88 turns ratio?

The full specification is 1CT:2.88CT ±3%, with center taps on both sides. Check pin assignments, winding polarity and the winding sections used in your circuit. Do not calculate the final output simply by multiplying the input by 2.88; drive, rectification and load conditions also require assessment.

Is sufficient board height enough to use WHST06Q?

No. The WHST06Q02E0 drawing specifies a maximum height of 4.10 mm and provides package dimensions, pin spacing and a suggested pad layout. Check board clearances, orientation and connections against that drawing. Available space alone does not establish footprint or electrical compatibility.

How can I assess WHST06Q as a replacement?

Provide the original manufacturer and full part number, datasheet revision, input/output conditions, frequency, load and PCB constraints. Add the requested sample quantity. Your sales engineer coordinates FAE matching and difference assessment. There is no automatic drop-in replacement decision; candidates require validation in the actual circuit.

Who manufactures the WHST06Q push-pull transformer?

VOOHU does, in its own magnetics factory in Mianyang, China. VOOHU manufactures WHST06Q02E0 alongside its other WHST push-pull families, so you can compare it with WHST06K step-up parts from the same supplier.

What switching frequency suits an 86 μH push-pull transformer?

No single answer: the frequency must keep magnetizing current and core flux within limits at your input voltage and duty cycle, and lower inductance needs a higher frequency. Check the WHST06Q02E0 datasheet conditions with our FAE team.

Should I consider WHST06K instead of the WHST06Q transformer?

Consider WHST06K if you need 4,000 VAC or exactly 1:2 or 1:3, at 340 μH. WHST06Q02E0 lists 2,500 VAC, 86 μH and 1:2.88, with lower DCR on both windings.

Engineer support

WHST06Q push-pull transformer samples and review

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.