Skip to main content
VOOHU WHST06Q Push-Pull Transformer products

Transformer products

WHST06Q Push-Pull Transformer

Check the winding arrangement against your power-supply requirements. The WHST06Q family currently lists WHST06Q02E0, with 86 μH minimum inductance, a 1CT:2.88CT turns ratio and specified 2500 VAC dielectric test conditions. Review design files or send your requirements or existing part number for sales and FAE support.

Part number search & selector

Find WHST06Q Push-Pull Transformer part numbers

The table uses the current English-site product records, published selection fields and part-specific technical-file links.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

WHST06Q Push-Pull Transformer product selection results
Image Part number Datasheet Compare Downloads SeriesL(μH)Turns RatioDCR1(mΩ)DCR2(mΩ)Isolation(VAC)Operating Temperature(℃) Sample
VOOHU WHST06Q02E0 WHST06Q Push-Pull Transformer WHST06Q02E0 SPEC WHST06Q861:2.881005002500-40℃ to 125℃

How to select

A practical selection sequence

Narrow the published fields in sequence, compare the remaining candidates and verify the part-specific files before design-in.

  1. 01

    Define the supply requirements

    Record input range, output voltage, continuous load, startup needs, available space and thermal constraints.

  2. 02

    Review the driver and windings

    Identify the driver IC or circuit, operating frequency and drive arrangement, then check turns ratio, center taps and pins.

  3. 03

    Compare electrical and mechanical requirements

    Review isolation test conditions, inductance, DCR, leakage inductance and package. Confirm the required volt-time capability in the applicable document or with engineering.

  4. 04

    Check the files and validate the candidate

    Confirm document revisions and arrange sample testing. Request pricing directly for an identified part; have the FAE compare the original and candidate parts for a replacement project.

Key selection parameters

What each filter helps you decide

01

Turns ratio and center taps

Identify the stated pins and winding sections. An abbreviated ratio is not a regulated output-voltage specification.

02

Inductance

Check measurement frequency, voltage and the stated minimum or tolerance. Similar values can have different test conditions.

03

DCR and leakage inductance

Compare the specified winding, conditions and maximum or typical value. These figures alone do not establish power, efficiency or temperature rise.

04

Isolation test conditions

Check AC/DC, test voltage, duration and pins together. A single test-voltage figure does not establish operating voltage or an insulation classification.

05

Volt-time capability

Review it against the voltage applied to the winding and its duration. Submit your drive conditions for confirmation where the part document does not provide this parameter.

06

Pins and package

Check polarity dots, center taps, dimensions and land pattern. A matching outline does not establish electrical compatibility.

Product family comparison

Compare the published Series

Use this summary as a routing step, then verify every required value in the exact part-number row and linked technical files.

Return to the selector ↑
SeriesPartsL(μH)Turns RatioDCR1(mΩ)DCR2(mΩ)Isolation(VAC)Operating Temperature(℃)Action
WHST06E64751:1.1, 1:1.3, 1:1.5, 1:1.7, 1:2100010003000, 3100-40℃ to 125℃Filter →
WHST06D7100, 200, 538, 600, 6801:1.07, 1:1:3.4, 1.2:1, 1.75:1, 3:4, 3:8, 4:1237, 250, 280, 350, 40070, 125, 220, 290, 520, 882, 9002500, 3000, 4000-40℃ to 125℃Filter →
WHST06K23401:2, 1:37501300, 15004000-40℃ to 125℃Filter →
WHST06Q1861:2.881005002500-40℃ to 125℃Filter →
WHST06018340, 538, 6801:1, 1:1.7, 1:2, 2:1, 3:4, 3:5, 3:8, 4:3, 8:3, 8:9700, 750, 900, 1300, 1500700, 750, 900, 1000, 1200, 1300, 15004000-40℃ to 125℃Filter →
WHST08815371:1:0.45:0.456603302100-40℃ to 125℃Filter →

Technical performance & application fit

Validate the complete design context

Application suitability is part-number specific. Treat the catalog fields as a shortlist, then confirm the design against the linked technical files.

Application review

RS485/CAN interface isolated power

  • Specify the isolated-side voltage, transceiver and other loads, startup requirements and isolation boundary. This review concerns the power supply, not RS485/CAN data-signal transmission through the transformer.
Application review

Industrial control auxiliary power

  • Share the control board's input range, output rails and loads, ambient conditions and available space to compare winding and thermal requirements.
Application review

Gate-driver power supplies

  • Provide the driver part number, required supply rails and load, isolation requirements and drive arrangement for a part-specific FAE assessment.
Get technical support →

Downloads & technical resources

Find files by part number

Search a full or partial SKU, then open its datasheet, 3D model or PCB footprint without returning to the product table.

1
PDF datasheets listed
1
3D file sets listed
1
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Category overview

Push-pull transformers in isolated DC-DC stages

These parts belong inside an isolated converter, which is what separates them from a complete power module.

01

A component, not a module

A push-pull transformer provides the isolated magnetic coupling in a converter topology. It is not a finished DC-DC module: no switching controller, no rectification, no regulation. You supply those. If you need a drop-in isolated supply, buy a module; if you are designing the converter, this is the part.

02

Turns ratio sets the output

The ratio between primary and secondary windings, with the input voltage and the topology, determines the output voltage before regulation. Parts with multiple secondaries have a ratio for each. Read each winding's ratio from the datasheet rather than inferring it from the part number, because notation varies between series.

03

Inductance and frequency work together

Primary inductance, switching frequency and input voltage together determine how far the core is driven each cycle. Running a transformer below its intended frequency pushes the core toward saturation. Confirm the frequency range from the datasheet and verify flux margin at worst case.

FAQ & related guides

Questions before design-in

These answers guide the page workflow. Part-specific engineering limits still come from the linked technical files.

Does WHST06Q offer several parts to compare?

The current selector lists one part, WHST06Q02E0. This page supports checks of its winding arrangement, specifications and layout; it does not imply multiple interchangeable variants. For a different ratio or package, compare the main selector or submit your power requirements for sales and FAE review.

Does the 5 V input and 12 V output example define a fixed output?

No. The datasheet lists 5 V input, 12 V output, 460 mA and 400 kHz as typical application conditions and notes that results vary by application. This is not a regulated power-module guarantee. Provide the driver circuit, rectification and load for FAE review and sample validation.

How should I use the 1:2.88 turns ratio?

The full specification is 1CT:2.88CT ±3%, with center taps on both sides. Check pin assignments, winding polarity and the winding sections used in your circuit. Do not calculate the final output simply by multiplying the input by 2.88; drive, rectification and load conditions also require assessment.

Is sufficient board height enough to use WHST06Q?

No. The WHST06Q02E0 drawing specifies a maximum height of 4.10 mm and provides package dimensions, pin spacing and a suggested pad layout. Check board clearances, orientation and connections against that drawing. Available space alone does not establish footprint or electrical compatibility.

How can I assess WHST06Q as a replacement?

Provide the original manufacturer and full part number, datasheet revision, input/output conditions, frequency, load and PCB constraints. Add the requested sample quantity. Your sales engineer coordinates FAE matching and difference assessment. There is no automatic drop-in replacement decision; candidates require validation in the actual circuit.

Engineer support

Continue after product selection

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are free of charge. Sample quantity and lead time depend on the part number and project stage. Sales will respond on business days.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.