Pluggable I/O component type
Distinguish cage, PCB receptacle and integrated assembly to define the purchase.
I/O Connector products
Select PCB receptacles, cages or integrated assemblies for an SFP+ host interface. Compare PCB mounting, module access, light pipes and thermal design as well as port count. Validate signal requirements and mechanical fit against the selected part’s documentation.
Part number search & selector
The table uses the current English-site product records, published selection fields and part-specific technical-file links.
* Frozen Image and Part Number columns · drag horizontally to review all specifications
| Image | Part number | Datasheet | Compare | Downloads | Pluggable I/O product type | Overall dimensions | Data Rate (Max) (Gb/s) | Installation Type | Ports | Included Lightpipe | Heat dissipation | Connector Gold Plated | Nickel Plated Shell | Sample |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
WH29DTD19D1S01 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 4 | ▽△▽△ | Heat dissipation holes | None | Ni 30U |
|
||
|
WH292R029DBS02 | SPEC | Cage | SFP+ | 10G | Press-Fit | 1 x 2 | ○ ○ | Heat dissipation holes | 30U | None |
|
||
|
WHSFP10812W003 | SPEC | Cage | SFP+ | 10G | — | 1 x 2 | NONE | Heat dissipation holes | None | None |
|
||
|
WHSFP06326F002 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 6 | NONE | Heat dissipation holes | None | None |
|
||
|
WHSFP16026F018 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 6 | △▽ | Heat dissipation holes | 30U | Ni 30U |
|
||
|
WHSFP15624F020 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 4 | △▽ | Heat dissipation holes | 30U | Ni 30U |
|
||
|
WHSFP15624F030 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 4 | ▽ △ | Heat dissipation holes | 30U | Ni 30U |
|
||
|
WHSFP15524F009 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 4 | NONE | Heat dissipation holes | 30U | Ni 30U |
|
||
|
WHSFP15624F029 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 4 | ▽△▽△ | Heat dissipation holes | 30U | Ni 30U |
|
||
|
WH81-123-Y0011-1 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 3 | △▽ | Heat dissipation holes | 30U | None |
|
||
|
WH81-123-Y0010-1 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 3 | ▽△▽△ | Heat dissipation holes | 30U | None |
|
||
|
WH81-123-Y0007-1 | SPEC | Cage+Connector | SFP+ | 10G | Press-Fit | 2 x 3 | NONE | Heat dissipation holes | 30U | None |
|
||
|
WH81-116-Y0012-1 | SPEC | Cage | SFP+ | 10G | Press-Fit | 1 x 6 | NONE | Heat dissipation holes | None | Ni 30U~80U |
|
||
|
WHSFP10111W124 | SPEC | Cage | SFP+ | 10G | Press-Fit | 1 x 1 | NONE | Heat Sink | None | Ni 30U |
|
||
|
WH81-111-Y0016-1 | SPEC | Cage | SFP+ | 10G | Press-Fit | 1 x 1 | NONE | Heat dissipation holes | None | None |
|
||
|
WHSFP11214W004 | SPEC | Cage | SFP+ | 10G | Solder | 1 x 4 | NONE | Heat dissipation holes | None | None |
|
||
|
WHSFP10612W042 | SPEC | Cage | SFP+ | 10G | Press-Fit | 1 x 2 | NONE | Heat Sink | None | None |
|
||
|
WHSFP10211W037 | SPEC | Cage | SFP+ | 10G | Press-Fit | 1 x 1 | ○ ○ | Heat dissipation holes | None | Ni 30U |
|
||
|
WH81-114-Y0017-1 | SPEC | Cage | SFP+ | 10G | Press-Fit | 1 x 4 | ○ ○ | Heat dissipation holes | None | None |
|
||
|
WHSFP11014W085 | SPEC | Cage | SFP+ | 10G | Press-Fit | 1 x 4 | NONE | Heat Sink | None | None |
|
Broaden the selected filters or clear the current search.
Product family quick links
Counts reflect the current published product data.
How to select
Narrow the published fields in sequence, compare the remaining candidates and verify the part-specific files before design-in.
Specify a cage, PCB receptacle or assembly, then identify the target SFP or QSFP family.
Review 1×N/2×N layout against the panel, PCB and press-fit or solder process.
Confirm the supplied light pipes and heat sinks, module power, airflow and grounding.
Validate fit, signal and thermal conditions using the part-specific documents before moving to production sourcing.
Key selection parameters
Distinguish cage, PCB receptacle and integrated assembly to define the purchase.
SFP/SFP+/SFP28/QSFP identify interface families, not dimensions in millimeters.
Check rows, ports per row, panel and PCB drawings together.
Review PCB and process requirements separately for press-fit and solder mounting.
Check legends, positions, module power and airflow, and confirm accessory inclusion.
Product family comparison
Use this summary as a routing step, then verify every required value in the exact part-number row and linked technical files.
Return to the selector ↑| Pluggable I/O product type | Parts | Overall dimensions | Data Rate (Max) (Gb/s) | Installation Type | Ports | Included Lightpipe | Heat dissipation | Connector Gold Plated | Nickel Plated Shell | Action |
|---|---|---|---|---|---|---|---|---|---|---|
| Cage | 72 | SFP, SFP+, SFP28, QSFP/QSFP+, QSFP28, QSFPDD | 5G, 10G, 25G, 40G, 100G, 400G | Solder, Press-Fit, Not specified | 1 x 1, 1 x 2, 1 x 4, 1 x 5, 1 x 6, 2 x 1 | NONE, ○ ○, △ ▽, ○, Not specified | Heat dissipation holes, Heat Sink, Not specified | 30U, None, Not specified | Ni 30U, Ni 30U~50U, Ni 30U~80U, None, Not specified | Filter → |
| Connector | 12 | SFP, SFP+, SFP28, QSFP/QSFP+, QSFP28, QSFPDD, QSFP56, QSFP112 | 5G, 10G, 25G, 40G, 100G, 200G, 400G | -, Not specified | 1 x 1 | NONE | -, Not specified | 15U, 30U, None | Ni 50U, None | Filter → |
| Cage+Connector | 141 | SFP, SFP+, SFP28, QSFP/QSFP+, QSFP28, QSFP56, Not specified | 5G, 10G, 25G, 40G, 100G, 200G | Press-Fit | 2 x 1, 2 x 2, 2 x 3, 2 x 4, 2 x 5, 2 x 6, 2 x 8, 2 x 12 | NONE, ○ ○, ▽△▽△, △ ▽△▽, ▽ △, ▽△, △▽, △ ▽, △○▽, ▽○△, △□▽, ▽□△, 口△▽口 | Heat dissipation holes, Heat Sink | 15U, 30U, None | Ni 30U, Ni 50U, None | Filter → |
Technical performance & application fit
Application suitability is part-number specific. Treat the catalog fields as a shortlist, then confirm the design against the linked technical files.
Downloads & technical resources
Search a full or partial SKU, then open its datasheet, 3D model or PCB footprint without returning to the product table.
Showing representative available file sets. Search to find a specific SKU.
VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.
Category overview
Most of the confusion in this category comes from three separate things being encoded in one part description.
Discuss a new design
Contact FAE for a replacement assessment.
Already have a part number? Request samples or a quote.
SFP, SFP+ and SFP28 share a mechanical form factor and differ in the data rate they are qualified for. The QSFP line, QSFP+, QSFP28, QSFP56 and QSFP-DD, is a physically larger four-lane form factor. A mechanical fit between two of these proves nothing about signal integrity at your rate.
A figure such as 1x1, 1x4, 2x1 or 2x5 describes how the ports are arranged, rows first and columns second. A ganged row and a stacked column with the same port count need completely different panel cutouts and board footprints, so read it before the panel is laid out.
Parts are supplied as a cage alone, a PCB receptacle alone, or the two together. On top of that sit press-fit or solder tails, optional heat sinks and light pipes, and a stated contact plating thickness. Each affects the assembly process and long-term contact reliability, so specify them all.
FAQ & related guides
These answers guide the page workflow. Part-specific engineering limits still come from the linked technical files.
No. Connector specifications concern contacts, mounting and electrical performance; transceivers also have optical and protocol parameters. This page covers host-side components.
Review the part-specific mechanical, panel, PCB and module requirements and validate samples. Names and appearance alone do not establish replacement suitability.
Check the array, panel projection, module extraction, light pipes and nearby PCB components using the selected part drawing in the host assembly.
No. Obtain the legend and part-specific information for quantity, position and supplied content. Do not infer meaning from undefined symbols.
Provide existing connector/cage parts, module type, array, PCB/panel drawings and thermal needs for FAE to compare candidates and differences.
Engineer support
Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.
Include the document revision
Temperature, isolation voltage and PoE current basis
Pin count, pitch and spacing between pin rows
To help prioritize samples and evaluation
When you need candidates and a comparison of differences
Engineering review identifies candidate parts and explains the differences.
From the selector or engineering review
Prototyping / pilot build / production
Specify sample and production timing separately
Compliance documents, material declarations or third-party reports
Samples are free of charge. Sample quantity and lead time depend on the part number and project stage. Sales will respond on business days.