Skip to main content
VOOHU WHST088 Push-Pull Transformer products

Transformer products

WHST088 Push-Pull Transformer

Need to review a multi-winding connection? WHST088 currently lists WHST08802E0, with four windings, a 1:1:0.45:0.45 turns ratio and 537 μH minimum inductance. Check drive and rectifier connections against the winding diagram, then review isolation, temperature and PCB requirements. Your sales engineer can also coordinate FAE matching for an existing part.

Part number search & selector

Find WHST088 Push-Pull Transformer part numbers

The table uses the current English-site product records, published selection fields and part-specific technical-file links.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

WHST088 Push-Pull Transformer product selection results
Image Part number Datasheet Compare Downloads SeriesL(μH)Turns RatioDCR1(mΩ)DCR2(mΩ)Isolation(VAC)Operating Temperature(℃) Sample
VOOHU WHST08802E0 WHST088 Push-Pull Transformer WHST08802E0 SPEC WHST0885371:1:0.45:0.456603302100-40℃ to 125℃

How to select

A practical selection sequence

Narrow the published fields in sequence, compare the remaining candidates and verify the part-specific files before design-in.

  1. 01

    Define the supply requirements

    Record input range, output voltage, continuous load, startup needs, available space and thermal constraints.

  2. 02

    Review the driver and windings

    Identify the driver IC or circuit, operating frequency and drive arrangement, then check turns ratio, center taps and pins.

  3. 03

    Compare electrical and mechanical requirements

    Review isolation test conditions, inductance, DCR, leakage inductance and package. Confirm the required volt-time capability in the applicable document or with engineering.

  4. 04

    Check the files and validate the candidate

    Confirm document revisions and arrange sample testing. Request pricing directly for an identified part; have the FAE compare the original and candidate parts for a replacement project.

Key selection parameters

What each filter helps you decide

01

Turns ratio and center taps

Identify the stated pins and winding sections. An abbreviated ratio is not a regulated output-voltage specification.

02

Inductance

Check measurement frequency, voltage and the stated minimum or tolerance. Similar values can have different test conditions.

03

DCR and leakage inductance

Compare the specified winding, conditions and maximum or typical value. These figures alone do not establish power, efficiency or temperature rise.

04

Isolation test conditions

Check AC/DC, test voltage, duration and pins together. A single test-voltage figure does not establish operating voltage or an insulation classification.

05

Volt-time capability

Review it against the voltage applied to the winding and its duration. Submit your drive conditions for confirmation where the part document does not provide this parameter.

06

Pins and package

Check polarity dots, center taps, dimensions and land pattern. A matching outline does not establish electrical compatibility.

Product family comparison

Compare the published Series

Use this summary as a routing step, then verify every required value in the exact part-number row and linked technical files.

Return to the selector ↑
SeriesPartsL(μH)Turns RatioDCR1(mΩ)DCR2(mΩ)Isolation(VAC)Operating Temperature(℃)Action
WHST06E64751:1.1, 1:1.3, 1:1.5, 1:1.7, 1:2100010003000, 3100-40℃ to 125℃Filter →
WHST06D7100, 200, 538, 600, 6801:1.07, 1:1:3.4, 1.2:1, 1.75:1, 3:4, 3:8, 4:1237, 250, 280, 350, 40070, 125, 220, 290, 520, 882, 9002500, 3000, 4000-40℃ to 125℃Filter →
WHST06K23401:2, 1:37501300, 15004000-40℃ to 125℃Filter →
WHST06Q1861:2.881005002500-40℃ to 125℃Filter →
WHST06018340, 538, 6801:1, 1:1.7, 1:2, 2:1, 3:4, 3:5, 3:8, 4:3, 8:3, 8:9700, 750, 900, 1300, 1500700, 750, 900, 1000, 1200, 1300, 15004000-40℃ to 125℃Filter →
WHST08815371:1:0.45:0.456603302100-40℃ to 125℃Filter →

Technical performance & application fit

Validate the complete design context

Application suitability is part-number specific. Treat the catalog fields as a shortlist, then confirm the design against the linked technical files.

Application review

RS485/CAN interface isolated power

  • Specify the isolated-side voltage, transceiver and other loads, startup requirements and isolation boundary. This review concerns the power supply, not RS485/CAN data-signal transmission through the transformer.
Application review

Industrial control auxiliary power

  • Share the control board's input range, output rails and loads, ambient conditions and available space to compare winding and thermal requirements.
Application review

Gate-driver power supplies

  • Provide the driver part number, required supply rails and load, isolation requirements and drive arrangement for a part-specific FAE assessment.
Get technical support →

Downloads & technical resources

Find files by part number

Search a full or partial SKU, then open its datasheet, 3D model or PCB footprint without returning to the product table.

1
PDF datasheets listed
1
3D file sets listed
1
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Category overview

Push-pull transformers in isolated DC-DC stages

These parts belong inside an isolated converter, which is what separates them from a complete power module.

01

A component, not a module

A push-pull transformer provides the isolated magnetic coupling in a converter topology. It is not a finished DC-DC module: no switching controller, no rectification, no regulation. You supply those. If you need a drop-in isolated supply, buy a module; if you are designing the converter, this is the part.

02

Turns ratio sets the output

The ratio between primary and secondary windings, with the input voltage and the topology, determines the output voltage before regulation. Parts with multiple secondaries have a ratio for each. Read each winding's ratio from the datasheet rather than inferring it from the part number, because notation varies between series.

03

Inductance and frequency work together

Primary inductance, switching frequency and input voltage together determine how far the core is driven each cycle. Running a transformer below its intended frequency pushes the core toward saturation. Confirm the frequency range from the datasheet and verify flux margin at worst case.

FAQ & related guides

Questions before design-in

These answers guide the page workflow. Part-specific engineering limits still come from the linked technical files.

Does 1:1:0.45:0.45 mean four isolated outputs?

No. It describes the turns relationship of N1, N2, N3 and N4. It does not define the number of outputs, their voltages or isolation ratings between them. Check drive and rectifier connections, loads and insulation requirements. Four windings must not be described as four independent power supplies.

Can I compare the 537 μH value directly with other families?

First align the measurement conditions. For WHST08802E0, 537 μH is the minimum inductance between pins 1–3 at 250 kHz and 0.1 V. Other families may use different pin intervals, frequencies or tolerance notation. The number alone does not establish equivalent behavior under the same drive conditions.

Why should I specify every supply rail and load?

The turns relationship alone does not establish the rectified outputs. For a multi-rail design, describe each voltage, load variation, reference ground and startup requirement, along with drive and rectification. Your sales engineer coordinates FAE assessment of the connections and candidate, then helps define sample validation.

How should I read the WHST088 dielectric-test specification?

Read voltage type, current limit and duration together. The WHST08802E0 datasheet specifies 3000 VDC, 1 mA, 60 s or 3750 VDC, 1 mA, 2 s. These are dielectric-test conditions, not continuous working-voltage ratings. Do not simply convert them into an AC specification to match an application requirement.

How do I assess WHST088 against an existing four-winding part?

Provide the original part, datasheet revision, winding diagram and pinout, plus input, output rails, loads and PCB limits. Sales coordinates FAE review of connection, electrical and mechanical differences. Matching winding counts or turns ratios does not prove drop-in compatibility. Request samples and a quote after candidate confirmation.

Engineer support

Continue after product selection

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are free of charge. Sample quantity and lead time depend on the part number and project stage. Sales will respond on business days.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.