Skip to main content
PRODUCT CATEGORY · TRANSFORMERS

Electronic Transformers

Explore VOOHU electronic transformers for Ethernet interfaces, BMS communication, audio circuits and isolated power supplies. Choose a product family below to review selection requirements, or contact our team for samples and quotations.

TRANSFORMER FAMILIES

Explore Transformer Families

Choose a family by circuit function, then review model specifications and datasheets.

Ethernet & LAN Transformers

Transformers for isolation and signal coupling in Ethernet interfaces. Review PHY requirements, target data rate and mounting needs when selecting a model.

Data rate & PHY requirementsPackage & mounting

CHIP LAN

Explore the VOOHU CHIP LAN series for Ethernet interface designs. Check each device’s circuit function, package and connection requirements in its datasheet.

Device functionPackage & connections

BMS Isolation Transformers

Transformers for isolated communication links in battery management systems. Check transceiver requirements, channel configuration and isolation test conditions.

Interface & channelsIsolation requirements

Audio Transformers

Transformers for audio signal isolation or impedance matching, depending on the model. Review circuit function, impedance ratio and frequency range.

Circuit functionImpedance & frequency

PoE Power Transformers

Power transformers for isolated power stages in PoE applications. Review input range, output requirements and converter topology when selecting a model.

Input & output requirementsConverter topology

Push-Pull Transformers

Transformers for isolated power supplies using a push-pull topology. Check driver requirements, input voltage, turns ratio and operating frequency.

Driver & frequencyInput voltage & turns ratio
TYPE GUIDANCE

Which Transformer Does Your Circuit Need?

Need help identifying the right family? Contact our team →

Signal transformers provide coupling, isolation or impedance matching for data or audio signals, depending on the circuit and device. Selection focuses on interface requirements, signal frequency or data rate, transmission characteristics and isolation conditions—not on supplying a power-conversion output.

Power transformers are selected for power conversion in a specified topology. Start with input voltage range, output voltage and current, switching frequency and isolation requirements. Then check winding parameters, thermal performance and size constraints.

A PoE design may use both Ethernet magnetics and a separate transformer in an isolated DC-DC stage. These components serve different functions. PoE-capable Ethernet magnetics must also meet the relevant current requirements. Do not select or interchange these components based on the word “PoE” alone.

For signal transformer selection, check:
  • Interface and circuit function
  • Data rate or frequency range
  • Turns ratio / impedance requirements, as applicable
  • Isolation requirements and test conditions
  • Package, pinout and mounting
  • Operating temperature range
For power transformer selection, check:
  • Input voltage range
  • Output voltage, current and power
  • Converter topology and switching frequency
  • Turns ratio, inductance and winding-current requirements
  • Isolation and thermal requirements
  • Package, pinout and height constraints
SELECTION HELP

Selection, Datasheets & Samples

Find out how to locate technical documents, prepare your selection request and arrange samples or a quotation.

Contact our team →
Where can I find a transformer datasheet?
Open the relevant product family and locate the exact part number. Check the product page for its datasheet. If the file is unavailable or you need help confirming the revision, contact us with the part number.
What should I provide for transformer selection support?
Share your application, key electrical requirements, package constraints and current part number, if available. A sales engineer will review your request and involve an FAE when needed. You do not need to know the exact VOOHU part number to start.
How can I request samples or a quotation?
Send the part number or your requirements, sample quantity and destination country. Our team will confirm the suitable model, pricing, availability and lead time before you place an order. Shipment is arranged after order and payment confirmation. Volume pricing is quoted for your project.
Can you help if my required part is not listed?
Share the current part number, datasheet or key requirements. Our team can review available catalog options or assess a custom request. Any proposed alternative requires engineering validation; custom scope and lead time are confirmed for the specific project.

Need Selection Support, Samples or a Quote?

Share your application requirements or current part number. Our sales engineers will coordinate FAE support when needed and help confirm product options, technical documents and sample arrangements. Pricing and lead time are confirmed for your request.

Contact Our Team

Please include your requirements or part number. For samples or a quote, add the quantity and destination country.