Skip to main content
VOOHU WHST06K Push-Pull Transformers products

Transformers

WHST06K Push-Pull Transformers

WHST06K02A0 and WHST06K14A0 offer 1CT:2CT and 1CT:3CT winding ratios. Both datasheets specify 340 μH minimum inductance and a 4000 Vrms isolation test rating. Compare candidates against your driver circuit, target supply rails and load, or share your application conditions for an FAE review of the sample-validation approach.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

  • Own factories: connectors in Dongguan, magnetics in Mianyang
  • 1,500+ customers, including 150+ listed companies
  • ISO 9001 and ISO 14001 certified
  • Certificates and test reports →

Part number search & selector

Find WHST06K Push-Pull Transformers part numbers

Filter WHST06K by turns ratio and secondary DCR; inductance, primary DCR, isolation and temperature are the same for both.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

WHST06K Push-Pull Transformers product selection results
Image Part number Datasheet Compare Downloads SeriesL(μH)Turns RatioDCR1(mΩ)DCR2(mΩ)Isolation(VAC)Operating Temperature(℃) Sample
VOOHU WHST06K14A0 WHST06K Push-Pull Transformers WHST06K14A0 SPEC WHST06K3401:375015004000-40℃ to 125℃
VOOHU WHST06K02A0 WHST06K Push-Pull Transformers WHST06K02A0 SPEC WHST06K3401:275013004000-40℃ to 125℃

Series overview

WHST06K push-pull transformers for step-up rails

A WHST06K push-pull transformer raises a low input to an isolated rail well above it, such as an isolated bias supply for a gate driver. It is also described as an isolated power transformer. Both parts share 340 μH, 750 mΩ primary DCR, 4,000 VAC isolation and −40 °C to +125 °C, and differ in ratio and secondary DCR. For ratios just above 1:1, see WHST06E push-pull transformers.

01

Choosing 1:2 or 1:3

WHST06K02A0 is 1:2 and WHST06K14A0 is 1:3. Size the rail at minimum input and full load, add rectifier and winding drops, then pick the ratio that covers it.

02

Secondary DCR

The extra turns of WHST06K14A0 show up as 1,500 mΩ on the secondary, against 1,300 mΩ for WHST06K02A0; at higher load current, budget for the extra drop.

03

Shared primary values

Both WHST06K transformers list 340 μH and 750 mΩ on the primary, so your driver sees the same magnetizing current with either ratio and the drive frequency can stay as it is.

04

Temperature rating

WHST06K14A0 and WHST06K02A0 are rated −40 °C to +125 °C; that wide range does not mean automotive qualification, so check the datasheet for any you need.

Open the Push-Pull Transformers selection guide →

Applications

WHST06K push-pull transformer use cases

Step-up ratios matter when the isolated side needs more voltage.

Gate drivers

Bias for IGBT and SiC gate drivers

Inverters, motor drives and industrial chargers need a floating bias rail per high-side switch; a push-pull transformer for gate driver supplies, such as WHST06K14A0 at 1:3, builds it from a low input.

Analog

Higher-voltage analog rails

Isolated amplifiers, 4–20 mA loops and sensor excitation can need an isolated power supply above the logic rail. WHST06K02A0 at 1:2 fits, and its center-tapped secondary can feed split positive and negative rails.

Energy

Inverter and storage control boards

Solar inverters and energy storage converters need isolated DC-DC rails across high DC links. Both WHST06K parts list 4,000 VAC; confirm with your insulation design that this test level fits each boundary.

Downloads & technical resources

WHST06K push-pull transformer datasheets and footprints

Search by part number for each WHST06K datasheet, 3D model and PCB footprint, then check center taps and pin spacing.

2
PDF datasheets listed
2
3D file sets listed
2
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Sourcing

Buying WHST06K push-pull transformers from VOOHU

VOOHU is a manufacturer of push-pull transformers and makes WHST06K in its own magnetics factory in Mianyang. Both parts come with a datasheet, 3D model and PCB footprint.

01

Evaluation samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. For a quotation, give the ratio, quantity and build date; typical lead time is 7–10 days.

02

Replacing a step-up part

If you use another step-up push-pull transformer today, send its part number and datasheet; our FAE team checks ratio, inductance, DCR, isolation and footprint and suggests VOOHU candidates to validate with samples before production.

03

Company and quality

VOOHU is ISO 9001 and ISO 14001 certified. Since 2018 VOOHU has supplied more than 1,500 customers, including 150+ listed companies. Both WHST06K parts are made in its Mianyang magnetics factory.

FAQ & related guides

Your WHST06K push-pull transformer questions

Manufacturing, isolation test level and WHST06K versus WHST06E.

What are the main differences between WHST06K02A0 and WHST06K14A0?

Their turns ratios are 1CT:2CT and 1CT:3CT. Maximum secondary DCR is 1300 mΩ and 1500 mΩ, while maximum leakage inductance is 1.0 μH and 2.0 μH, respectively. Compare these against the output requirements and driver circuit, not just their shared 340 μH inductance.

Does WHST06K14A0's 1CT:3CT ratio guarantee three times the output voltage?

It specifies the turns relationship between the stated primary and secondary windings, not a regulated converter output. Actual output also depends on the drive method, rectification, circuit losses and load. Share the input range, target output and circuit so the FAE can assess the candidate and validation needs.

How should I use WHST06K02A0's 8 mm isolation spacing?

Its datasheet specifies at least 8 mm creepage and clearance between primary and secondary. Use this for an initial mechanical and isolation review, then assess the actual layout and applicable system requirements. It does not establish equipment certification and should not be carried over to K14A0 without verification.

Can WHST06K be considered for a gate-driver supply project?

Submit the project requirements for an FAE review of the actual circuit. Clarify whether you need isolated power for a gate driver or direct transmission of gate-drive pulses, then provide the rails, load and drive conditions. These are different design tasks; the product name alone does not establish connections or driver-IC compatibility.

How do I request a WHST06K replacement review, samples or pricing?

For an existing component, send the original datasheet, connections, input/output requirements and layout constraints. Your sales engineer will coordinate FAE matching. If K02A0 or K14A0 is already selected, send quantity, project stage and requested delivery date directly for samples or a quotation; a commercial inquiry need not wait for an additional technical review.

Does VOOHU manufacture WHST06K push-pull transformers itself?

Yes. VOOHU manufactures WHST06K push-pull transformers in its own magnetics factory in Mianyang, China, along with WHST06E and WHST060, so a design can change ratio without changing supplier.

What isolation does a WHST06K push-pull transformer list?

Both parts list 4,000 VAC, as WHST060 does, against 3,000 VAC or 3,100 VAC for WHST06E. It is a test value: read the duration and leakage current in the datasheet and check working voltage and creepage separately.

Should I use WHST06K or WHST06E for my rail?

Use WHST06K when the rail must sit well above the input or you need 1:3 at 4,000 VAC. WHST06E push-pull transformers step from 1:1.1 to 1:2 at 475 μH and 3,000 VAC or 3,100 VAC, for rails nearer the input.

Engineer support

WHST06K push-pull transformer samples and FAE input

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.