VOOHU 2 Electrode Gas Discharge Tubes products

Protective Component products

2 Electrode Gas Discharge Tubes

A two-electrode tube protects one line to ground. The two ends are symmetric, so there is no polarity to observe. Select a DC breakdown above the line working voltage, then keep the path to ground short and wide so stray inductance does not add overshoot.

Part number search & selector

Find 2 Electrode Gas Discharge Tubes part numbers

Filter 2-electrode gas discharge tubes by DC breakdown, spark-over voltage, capacitance, package size, temperature and electrode count.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

2 Electrode Gas Discharge Tubes product selection results
Image Part number Datasheet Compare Downloads PinsVbr(DC.V)Spark-over Voltage/VCj/pfPackageOperating Temperature Sample
VOOHU WHGD400V1P0B 2 Electrode Gas Discharge Tubes WHGD400V1P0B SPEC 2 PIN40090013.2mm*2.7mm-40 °C to 85 °C
VOOHU WHGD200V1P0B 2 Electrode Gas Discharge Tubes WHGD200V1P0B SPEC 2 PIN20065013.2mm*2.7mm-40 °C to 85 °C
VOOHU WHGD090V1P0B 2 Electrode Gas Discharge Tubes WHGD090V1P0B SPEC 2 PIN9060013.2mm*2.7mm-40 °C to 85 °C

By electrode count

2 electrode and 3 electrode gas discharge tubes

A 2 electrode GDT protects one line to ground; a 3 electrode GDT shares one ground electrode between two lines so both fire together.

Series overview

Choosing a 2-electrode gas discharge tube

A 2-electrode gas discharge tube connects from a line to ground and stays open until a surge passes its spark-over voltage; the gas then ionizes and the tube carries the current. It is also sold as a 2-electrode GDT, 2-pole GDT, gas arrester or GDT surge arrester. These parts share a 3.2 mm × 2.7 mm package and 1 pF capacitance, with DC breakdown from 90 V to 400 V. For balanced pairs, compare the 3-electrode gas discharge tube.

01

DC breakdown voltage

WHGD090V1P0B breaks down at 90 V DC, WHGD200V1P0B at 200 V and WHGD400V1P0B at 400 V. Compare the lower tolerance limit, not the nominal value, with the highest steady line voltage.

02

Spark-over on fast surges

On a fast surge the tube fires at a higher voltage: 600 V for WHGD090V1P0B, 650 V for WHGD200V1P0B and 900 V for WHGD400V1P0B. The stage behind it must hold that voltage until the tube fires.

03

Shared package and capacitance

Every part here uses the 3.2 mm × 2.7 mm package with 1 pF, so a late change of breakdown voltage rarely needs a new layout.

04

Rated −40 °C to +85 °C

The selector rates these tubes from −40 °C to +85 °C; sealed outdoor housings can run well above the outside air.

Open the Gas Discharge Tubes (GDT) selection guide →

Applications

Where 2-electrode gas discharge tubes go

Use one as the first stage wherever a cable can bring in lightning surges.

Ethernet

RJ45 ports with and without PoE

The tube connects from the Bob-Smith termination of the cable-side center taps to chassis ground. Without PoE, WHGD090V1P0B at 90 V fits; with PoE, WHGD200V1P0B at 200 V keeps more margin.

Telecom

Analog phone and DSL lines

Fit one tube from tip and one from ring to ground. Ringing rides on the battery feed, so use WHGD200V1P0B at 200 V or WHGD400V1P0B at 400 V.

Fieldbus

Outdoor fieldbus and control wiring

Cables between buildings pick up induced surges. A 2-electrode GDT from each line to earth takes most of the energy; a resistor and a bidirectional ESD diode handle the rest.

Documents

2-electrode gas discharge tube datasheets

Search by part number for each 2-electrode GDT datasheet and check breakdown tolerance, surge rating and land pattern before layout.

3
PDF datasheets listed
0
3D file sets listed
0
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Sourcing

Getting 2-electrode gas discharge tubes from VOOHU

VOOHU supplies 2-electrode gas discharge tubes along with TVS diodes, LAN transformers and RJ45 connectors for the same ports. A datasheet is published for each tube.

01

Samples for evaluation

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Send the part numbers and planned volume, and we will confirm availability.

02

Second source for a GDT

To replace a GDT from another supplier, send its part number and datasheet. Our FAE team compares breakdown, spark-over, surge current, capacitance and size, then proposes candidates to confirm with samples.

03

Quality management

VOOHU is ISO 9001 and ISO 14001 certified. Since 2018 VOOHU has supplied more than 1,500 customers, including 150+ listed companies.

FAQ

2-electrode gas discharge tube FAQ

Answers on PoE ports, DC supply lines and datasheet checks.

How is a 2 electrode GDT connected?

One end goes to the line being protected and the other to ground. The two ends are electrically symmetric, so there is no polarity to observe. Keep the path to ground as short and as wide as the layout allows, because stray inductance in that path adds voltage overshoot on a fast surge.

How many do I need for a multi-line port?

One two-electrode tube per line, each referenced to ground. If the lines form a balanced pair and you need them to fire together so the voltage between them stays small, compare a three-electrode part instead, which shares one ground electrode across both lines.

How do I pick the DC breakdown voltage?

Choose comfortably above the highest voltage the line reaches in normal service, including ripple, so the tube never fires during operation. Then confirm the impulse breakdown, which is considerably higher, does not exceed what the downstream circuit can withstand.

Will a 2 electrode GDT load my signal?

Barely. Capacitance is typically around one picofarad, far below a semiconductor clamp of comparable energy handling, which is why GDTs suit capacitance-sensitive lines. The tube is slow and its arc voltage is not zero, so a high-speed port still needs a faster second stage behind it.

How do I request samples or a quote?

With a complete part number, send the part number, quantity, delivery region and the date you need it. If you are still selecting, send the line type, working voltage and the surge standard you must meet, and a sales engineer will confirm candidates first.

Can VOOHU supply the 2-electrode gas discharge tube and LAN transformer for a PoE port?

Yes. VOOHU supplies these GDTs as well as LAN transformers and RJ45 connectors, so one inquiry covers the surge path from jack to PHY, and our FAE team can check the coordination.

Can a 2-electrode GDT sit directly across a DC supply?

Not on its own. Once fired, a tube holds a low arc voltage, and a DC source above that level can keep current flowing after the surge. Add a series metal oxide varistor or use a clamp that turns off by itself.

Which figures in a 2-electrode GDT datasheet matter beyond the selector?

Check the DC breakdown tolerance, the rate of rise behind the spark-over figure, the impulse discharge current and its repetitions, insulation resistance, and the glow and arc voltages.

Engineer support

2-electrode gas discharge tube samples and support

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.