VOOHU WHPT-EQ200 Planar Transformers: Select by Topology and Output products

Transformer products

WHPT-EQ200 Planar Transformers: Select by Topology and Output

Select multilayer-PCB-winding planar transformers for compact isolated DC-DC designs. WHPT-EQ200 includes 60 W and 71 W flyback families plus 90 W and 120 W active-clamp forward families, each with 3.3 V, 5 V, 12 V and 24 V output design options. Confirm the topology first, then compare inductance, turns ratio, output current and thermal requirements. Request samples or pricing directly for a selected part.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

  • Own factories: connectors in Dongguan, magnetics in Mianyang
  • 1,500+ customers, including 150+ listed companies
  • ISO 9001 and ISO 14001 certified
  • Certificates and test reports →

Part number search & selector

Find WHPT-EQ200 Planar Transformers: Select by Topology and Output part numbers

The table uses the current English-site product records, published selection fields and part-specific technical-file links.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

WHPT-EQ200 Planar Transformers: Select by Topology and Output product selection results
Image Part number Datasheet Compare Downloads ModelPower(W)Inductance(μH)Lk(μH Max)Turns RatioIast(A)Output(V/A) Sample
VOOHU WHPT-EQ200-014 WHPT-EQ200 Planar Transformers: Select by Topology and Output WHPT-EQ200-014 SPEC WHPT-EQ200-60W Series60210.51:1:0.5624V/2.4A
VOOHU WHPT-EQ200-013 WHPT-EQ200 Planar Transformers: Select by Topology and Output WHPT-EQ200-013 SPEC WHPT-EQ200-60W Series60210.51:0.5:0.5612V/5A
VOOHU WHPT-EQ200-012 WHPT-EQ200 Planar Transformers: Select by Topology and Output WHPT-EQ200-012 SPEC WHPT-EQ200-60W Series60210.51:0.25:0.55.45V/12A
VOOHU WHPT-EQ200-011 WHPT-EQ200 Planar Transformers: Select by Topology and Output WHPT-EQ200-011 SPEC WHPT-EQ200-60W Series60210.51:0.166:0.6665.43.3V/18A

How to select

A practical selection sequence

Narrow the published fields in sequence, compare the remaining candidates and verify the part-specific files before design-in.

  1. 01

    Establish the topology

    Distinguish flyback, active-clamp forward and other topologies. Include the controller or reference circuit.

  2. 02

    Define input and output conditions

    Provide input range, output voltage/current, switching frequency, duty cycle and startup conditions.

  3. 03

    Review magnetics and thermal design

    Compare inductance definitions, leakage, ratio, DCR and winding current. Check temperature rise, flux and cooling.

  4. 04

    Use part-specific files and validate

    Check pins, polarity, pads, insulation and assembly documents. Validate full-load and worst-case operation in the target circuit.

Key selection parameters

What each filter helps you decide

01

Rated power

The 60 W and 71 W parts are flyback; the 90 W and 120 W parts are active-clamp forward. Power and topology move together here.

02

Inductance

Primary magnetising inductance. Read it with switching frequency and input voltage, which together set the flux swing.

03

Leakage inductance

Quoted as a maximum. Leakage does not reach the secondary; it drives the spike your clamp or snubber has to absorb.

04

Turns ratio

Stated per winding set. With the input range and the topology it produces the listed output voltage, before regulation.

05

Output design point

The voltage and current the part was designed around inside a converter. It is not an output you can load directly.

Product family comparison

Compare the published product families

Use this summary as a routing step, then verify every required value in the exact part-number row and linked technical files.

Return to the selector ↑
ModelPartsPower(W)Inductance(μH)Lk(μH Max)Turns RatioIast(A)Output(V/A)Action
WHPT-EQ200-60W Series460210.51:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.55.4, 63.3V/18A, 5V/12A, 12V/5A, 24V/2.4AFilter →
WHPT-EQ200-71W Series471180.51:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.56.3, 6.63.3V/21A, 5V/14A, 12V/5.9A, 24V/2.9AFilter →
WHPT-EQ200-90W Series4902800.51:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5TBD3.3V/27A, 5V/18A, 12V/7.5A, 24V/3.7AFilter →
WHPT-EQ200-120W Series41202800.51:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5TBD3.3V/36A, 5V/24A, 12V/10A, 24V/5AFilter →

Technical performance & application fit

Validate the complete design context

Application suitability is part-number specific. Treat the catalog fields as a shortlist, then confirm the design against the linked technical files.

Application review

Telecom equipment and compact isolated DC-DC

  • Filter by height, input range and output requirements, then confirm topology before loss and thermal assessment.
Application review

PoE powered devices and industrial auxiliary supplies

  • For PoE, check the PD controller and system power budget. For industrial auxiliary power, review input range and insulation separately rather than applying a blanket family-wide conclusion.
Get technical support →

Downloads & technical resources

Find files by part number

Search a full or partial SKU, then open its datasheet, 3D model or PCB footprint without returning to the product table.

16
PDF datasheets listed
16
3D file sets listed
16
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Category overview

What planar construction changes, and what it does not

The construction buys repeatability and height. It does not turn the part into a finished power supply.

01

Windings are PCB layers

Instead of wire on a bobbin, the windings are copper layers in a multilayer board sandwiched between low-profile core halves. That gives a very repeatable build, low height and good thermal contact with the board. It also fixes the turns count in the layout, which is why the range is organised by design point.

02

Topology comes before power

The range splits into flyback families and active-clamp forward families. These store and transfer energy differently, so a transformer designed for one will not behave correctly in the other even at the same output power. Confirm your converter topology first; power and output voltage narrow it afterwards.

03

Output entries are design points

An entry such as 12 V at 10 A describes the operating point the transformer was designed around inside a complete converter, not a supply you can connect a load to. The controller, switching devices, rectification and output filtering are all yours. Leakage and thermal behaviour still need verifying on the real board.

FAQ & related guides

Questions before design-in

These answers guide the page workflow. Part-specific engineering limits still come from the linked technical files.

How does a planar transformer differ from a conventional wire-wound transformer?

A planar design uses a flat winding arrangement; this family specifically uses multilayer PCB windings. It offers a low-profile construction option, but losses, leakage, parasitic capacitance and cost remain design-specific. Not every planar transformer is inherently more efficient than a conventional design.

How do I choose between 60 W, 71 W, 90 W and 120 W families?

Start with topology: 60/71 W are flyback families, while 90/120 W are active-clamp forward. Then select the specific part for the required output voltage and current. The power label does not replace input-range, frequency, thermal or insulation validation; every voltage/current pair need not multiply to exactly the family label.

Does a 12 V or 24 V output entry mean I can connect DC and use it directly?

No. A transformer is a magnetic component within a converter, not a regulated DC-DC module. The output depends on topology, controller, switching frequency, ratio, rectification and feedback. Provide input range, output requirements and the controller so the complete circuit can be assessed.

How does 0.5 μH leakage differ from 21, 18 or 280 μH inductance?

Leakage and inductance are different parameters with different measurement arrangements. The 60 W table lists 21 μH±10%, the 71 W table lists 18 μH±10%, and 90/120 W list 280 μH minimum. Leakage is 0.5 μH maximum. Do not relabel 280 μH as a universal typical value or treat leakage as the working inductance.

Can all of these planar transformers be used in LLC or PoE supplies?

No blanket compatibility should be assumed. The documents specify flyback or active-clamp forward, not LLC merely because the construction is planar. The 60/71 W documents mention PoE applications, but the overall PoE power budget, PD controller, losses and compliance still need system review. Transformer power alone is insufficient.

If temperature rise is high, should I simply choose a higher-power part?

Not necessarily. Review input voltage, frequency, flux, winding RMS current, copper and core losses, and cooling. A higher-power family may also change topology and inductance, so it is not a direct replacement. Share operating conditions and thermal measurements for FAE assessment.

Are planar transformers with the same dimensions drop-in replacements?

Dimensions alone are insufficient. Compare topology, ratio, primary inductance, leakage, winding resistance, insulation, polarity and pads. FAE can identify candidates and explain differences, followed by electrical and thermal validation.

How do I request planar transformer pricing, samples or customization?

For a known part, request pricing with the quantity and destination. For a new project, start with topology, input range, output voltage/current and height limits; attach the current datasheet for replacement review. Custom electrical design, mechanics, tooling and timing are evaluated per project.

Engineer support

Continue after product selection

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

Your information will be used only to respond to this support request.

Published replacement reviews View all alternatives

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.