Rated power
The 60 W and 71 W parts are flyback; the 90 W and 120 W parts are active-clamp forward. Power and topology move together here.
Transformer products
Select multilayer-PCB-winding planar transformers for compact isolated DC-DC designs. WHPT-EQ200 includes 60 W and 71 W flyback families plus 90 W and 120 W active-clamp forward families, each with 3.3 V, 5 V, 12 V and 24 V output design options. Confirm the topology first, then compare inductance, turns ratio, output current and thermal requirements. Request samples or pricing directly for a selected part.
For OEM and volume orders. MOQ is one full reel, tray or tube per part.
Part number search & selector
The table uses the current English-site product records, published selection fields and part-specific technical-file links.
* Frozen Image and Part Number columns · drag horizontally to review all specifications
| Image | Part number | Datasheet | Compare | Downloads | Model | Power(W) | Inductance(μH) | Lk(μH Max) | Turns Ratio | Iast(A) | Output(V/A) | Sample |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
WHPT-EQ200-014 | SPEC | WHPT-EQ200-60W Series | 60 | 21 | 0.5 | 1:1:0.5 | 6 | 24V/2.4A |
|
||
|
WHPT-EQ200-013 | SPEC | WHPT-EQ200-60W Series | 60 | 21 | 0.5 | 1:0.5:0.5 | 6 | 12V/5A |
|
||
|
WHPT-EQ200-012 | SPEC | WHPT-EQ200-60W Series | 60 | 21 | 0.5 | 1:0.25:0.5 | 5.4 | 5V/12A |
|
||
|
WHPT-EQ200-011 | SPEC | WHPT-EQ200-60W Series | 60 | 21 | 0.5 | 1:0.166:0.666 | 5.4 | 3.3V/18A |
|
Broaden the selected filters or clear the current search.
Is this another brand's part number? Find the VOOHU replacement →
Product family quick links
Counts reflect the current published product data.
How to select
Narrow the published fields in sequence, compare the remaining candidates and verify the part-specific files before design-in.
Distinguish flyback, active-clamp forward and other topologies. Include the controller or reference circuit.
Provide input range, output voltage/current, switching frequency, duty cycle and startup conditions.
Compare inductance definitions, leakage, ratio, DCR and winding current. Check temperature rise, flux and cooling.
Check pins, polarity, pads, insulation and assembly documents. Validate full-load and worst-case operation in the target circuit.
Key selection parameters
The 60 W and 71 W parts are flyback; the 90 W and 120 W parts are active-clamp forward. Power and topology move together here.
Primary magnetising inductance. Read it with switching frequency and input voltage, which together set the flux swing.
Quoted as a maximum. Leakage does not reach the secondary; it drives the spike your clamp or snubber has to absorb.
Stated per winding set. With the input range and the topology it produces the listed output voltage, before regulation.
The voltage and current the part was designed around inside a converter. It is not an output you can load directly.
Product family comparison
Use this summary as a routing step, then verify every required value in the exact part-number row and linked technical files.
Return to the selector ↑| Model | Parts | Power(W) | Inductance(μH) | Lk(μH Max) | Turns Ratio | Iast(A) | Output(V/A) | Action |
|---|---|---|---|---|---|---|---|---|
| WHPT-EQ200-60W Series | 4 | 60 | 21 | 0.5 | 1:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5 | 5.4, 6 | 3.3V/18A, 5V/12A, 12V/5A, 24V/2.4A | Filter → |
| WHPT-EQ200-71W Series | 4 | 71 | 18 | 0.5 | 1:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5 | 6.3, 6.6 | 3.3V/21A, 5V/14A, 12V/5.9A, 24V/2.9A | Filter → |
| WHPT-EQ200-90W Series | 4 | 90 | 280 | 0.5 | 1:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5 | TBD | 3.3V/27A, 5V/18A, 12V/7.5A, 24V/3.7A | Filter → |
| WHPT-EQ200-120W Series | 4 | 120 | 280 | 0.5 | 1:0.166:0.666, 1:0.25:0.5, 1:0.5:0.5, 1:1:0.5 | TBD | 3.3V/36A, 5V/24A, 12V/10A, 24V/5A | Filter → |
Technical performance & application fit
Application suitability is part-number specific. Treat the catalog fields as a shortlist, then confirm the design against the linked technical files.
Downloads & technical resources
Search a full or partial SKU, then open its datasheet, 3D model or PCB footprint without returning to the product table.
Showing representative available file sets. Search to find a specific SKU.
VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.
Category overview
The construction buys repeatability and height. It does not turn the part into a finished power supply.
Instead of wire on a bobbin, the windings are copper layers in a multilayer board sandwiched between low-profile core halves. That gives a very repeatable build, low height and good thermal contact with the board. It also fixes the turns count in the layout, which is why the range is organised by design point.
The range splits into flyback families and active-clamp forward families. These store and transfer energy differently, so a transformer designed for one will not behave correctly in the other even at the same output power. Confirm your converter topology first; power and output voltage narrow it afterwards.
An entry such as 12 V at 10 A describes the operating point the transformer was designed around inside a complete converter, not a supply you can connect a load to. The controller, switching devices, rectification and output filtering are all yours. Leakage and thermal behaviour still need verifying on the real board.
FAQ & related guides
These answers guide the page workflow. Part-specific engineering limits still come from the linked technical files.
A planar design uses a flat winding arrangement; this family specifically uses multilayer PCB windings. It offers a low-profile construction option, but losses, leakage, parasitic capacitance and cost remain design-specific. Not every planar transformer is inherently more efficient than a conventional design.
Start with topology: 60/71 W are flyback families, while 90/120 W are active-clamp forward. Then select the specific part for the required output voltage and current. The power label does not replace input-range, frequency, thermal or insulation validation; every voltage/current pair need not multiply to exactly the family label.
No. A transformer is a magnetic component within a converter, not a regulated DC-DC module. The output depends on topology, controller, switching frequency, ratio, rectification and feedback. Provide input range, output requirements and the controller so the complete circuit can be assessed.
Leakage and inductance are different parameters with different measurement arrangements. The 60 W table lists 21 μH±10%, the 71 W table lists 18 μH±10%, and 90/120 W list 280 μH minimum. Leakage is 0.5 μH maximum. Do not relabel 280 μH as a universal typical value or treat leakage as the working inductance.
No blanket compatibility should be assumed. The documents specify flyback or active-clamp forward, not LLC merely because the construction is planar. The 60/71 W documents mention PoE applications, but the overall PoE power budget, PD controller, losses and compliance still need system review. Transformer power alone is insufficient.
Not necessarily. Review input voltage, frequency, flux, winding RMS current, copper and core losses, and cooling. A higher-power family may also change topology and inductance, so it is not a direct replacement. Share operating conditions and thermal measurements for FAE assessment.
Dimensions alone are insufficient. Compare topology, ratio, primary inductance, leakage, winding resistance, insulation, polarity and pads. FAE can identify candidates and explain differences, followed by electrical and thermal validation.
For a known part, request pricing with the quantity and destination. For a new project, start with topology, input range, output voltage/current and height limits; attach the current datasheet for replacement review. Custom electrical design, mechanics, tooling and timing are evaluated per project.
Engineer support
Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.
Include the document revision
Temperature, isolation voltage and PoE current basis
Pin count, pitch and spacing between pin rows
To help prioritize samples and evaluation
When you need candidates and a comparison of differences
Engineering review identifies candidate parts and explains the differences.
From the selector or engineering review
Prototyping / pilot build / production
Specify sample and production timing separately
Compliance documents, material declarations or third-party reports
Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.