Skip to main content
VOOHU WHPT-EQ200 60 W Flyback Planar Transformers products

Transformer products

WHPT-EQ200 60 W Flyback Planar Transformers

Compare 60 W planar transformers for isolated flyback DC-DC designs. The four parts, WHPT-EQ200-011 through WHPT-EQ200-014, correspond to 3.3 V, 5 V, 12 V and 24 V output design options. The listed primary inductance is 21 μH±10%. Confirm topology and input/output conditions before choosing a part and requesting samples.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

  • Own factories: connectors in Dongguan, magnetics in Mianyang
  • 1,500+ customers, including 150+ listed companies
  • ISO 9001 and ISO 14001 certified
  • Certificates and test reports →

Part number search & selector

Find WHPT-EQ200 60 W Flyback Planar Transformers part numbers

The table uses the current English-site product records, published selection fields and part-specific technical-file links.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

WHPT-EQ200 60 W Flyback Planar Transformers product selection results
Image Part number Datasheet Compare Downloads ModelPower(W)Inductance(μH)Lk(μH Max)Turns RatioIast(A)Output(V/A) Sample
VOOHU WHPT-EQ200-014 WHPT-EQ200 60 W Flyback Planar Transformers WHPT-EQ200-014 SPEC WHPT-EQ200-60W Series60210.51:1:0.5624V/2.4A
VOOHU WHPT-EQ200-013 WHPT-EQ200 60 W Flyback Planar Transformers WHPT-EQ200-013 SPEC WHPT-EQ200-60W Series60210.51:0.5:0.5612V/5A
VOOHU WHPT-EQ200-012 WHPT-EQ200 60 W Flyback Planar Transformers WHPT-EQ200-012 SPEC WHPT-EQ200-60W Series60210.51:0.25:0.55.45V/12A
VOOHU WHPT-EQ200-011 WHPT-EQ200 60 W Flyback Planar Transformers WHPT-EQ200-011 SPEC WHPT-EQ200-60W Series60210.51:0.166:0.6665.43.3V/18A

How to select

Selection guide for WHPT-EQ200 Planar Transformers: Select by Topology and Output

Selection steps, parameter explanations and the series comparison for WHPT-EQ200 Planar Transformers: Select by Topology and Output are on one page. Confirm the series there, then use this list for part numbers, files and samples.

Open the WHPT-EQ200 Planar Transformers: Select by Topology and Output selection guide →

Downloads & technical resources

Find files by part number

Search a full or partial SKU, then open its datasheet, 3D model or PCB footprint without returning to the product table.

4
PDF datasheets listed
4
3D file sets listed
4
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

FAQ & related guides

Questions before design-in

These answers guide the page workflow. Part-specific engineering limits still come from the linked technical files.

Which topology is specified for the 60 W family?

The current datasheet specifies flyback, not universal LLC or arbitrary converter use. Check input voltage, frequency, duty cycle, winding connections and core-reset requirements against the controller reference design before sample validation.

Which 60 W part lists a 12 V output?

WHPT-EQ200-013 corresponds to 12 V / 5 A in the family table. Also review input range, the flyback controller, ratio and cooling. It is not a standalone regulated 12 V module; validate samples in the target circuit.

How should I compare inductance and leakage for the 60 W family?

The table lists 21 μH±10% and 0.5 μH maximum leakage. Preserve minimum, tolerance and maximum qualifiers, and compare at 100 kHz, 1 V with the specified connections. Measurement frequency is not necessarily the required converter switching frequency.

Can Isat be used as output current?

No. In the 60/71 W documents, Isat refers to DC bias under a stated inductance-drop condition, not the secondary output current. The web label Iast should be checked and corrected to Isat; the two columns cannot be interchanged.

How do I request 60 W samples or replacement review?

For a selected part from WHPT-EQ200-011 to WHPT-EQ200-014, send the quantity and destination for pricing. For selection or replacement, provide input range, output voltage/current, the flyback controller and height limits. Sales will coordinate FAE matching.

Engineer support

Continue after product selection

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

Your information will be used only to respond to this support request.

Published replacement reviews View all alternatives

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.