Skip to main content
VOOHU PoE Power Transformers products

Transformer products

PoE Power Transformers

Explore VOOHU EP and EFD series for isolated DC-DC power designs in PoE powered devices. Shortlist by target output, load and package, then check the exact part's input conditions, converter topology and winding documentation. For a new design or an existing-part review, your sales engineer can coordinate FAE support.

Part number search & selector

Find PoE Power Transformers part numbers

The table uses the current English-site product records, published selection fields and part-specific technical-file links.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

PoE Power Transformers product selection results
Image Part number Datasheet Compare Downloads Package SizePower (W)Output Voltage (V)Output Current (A) Sample
VOOHU WHEP13779 PoE Power Transformers WHEP13779 SPEC EP13 Series25.2W12V≥ 2A
VOOHU WHEP13029 PoE Power Transformers WHEP13029 SPEC EP13 Series24W12V≥ 2A
VOOHU WHEPD13002 PoE Power Transformers WHEPD13002 SPEC EP13 Series25W5V5A
VOOHU WHEP13779 PoE Power Transformers WHEP13779 SPEC EP13 Series25.2W12V≥ 2A
VOOHU ST1388WH PoE Power Transformers ST1388WH SPEC EP13 Series24W12V≥ 2A
VOOHU ST1319WH PoE Power Transformers ST1319WH SPEC EP13 Series13W5V≥ 2A
VOOHU EP13S-M10 PoE Power Transformers EP13S-M10 SPEC EP13 Series20W12V1.08A~1.99A
VOOHU WH13P-12H5 PoE Power Transformers WH13P-12H5 SPEC EP13 Series25W12V≥ 2A
VOOHU WH13P-12H PoE Power Transformers WH13P-12H SPEC EP13 Series30W12V≥ 2A
VOOHU WH13P-12L2 PoE Power Transformers WH13P-12L2 SPEC EP13 Series12W12V0.41A~1.0A
VOOHU WH13P-50L PoE Power Transformers WH13P-50L SPEC EP13 Series13W5V≥ 2A
VOOHU WH13P-24L PoE Power Transformers WH13P-24L SPEC EP13 Series13W24V0.41A~1.0A
VOOHU WH13P-12L PoE Power Transformers WH13P-12L SPEC EP13 Series13W12V1.08A~1.99A
VOOHU ST1378WH PoE Power Transformers ST1378WH SPEC EP13 Series25W13.4V1.08A~1.99A
VOOHU ST1368WH PoE Power Transformers ST1368WH SPEC EP13 Series12W12V0.41A~1.0A
VOOHU ST1362WH PoE Power Transformers ST1362WH SPEC EP13 Series12W12V0.41A~1.0A
VOOHU ST1353WH PoE Power Transformers ST1353WH SPEC EP13 Series18W12V1.08A~1.99A
VOOHU ST1340WH PoE Power Transformers ST1340WH SPEC EP13 Series14W14V0.41A~1.0A
VOOHU ST1339WH PoE Power Transformers ST1339WH SPEC EP13 Series13W12V1.08A~1.99A
VOOHU ST1336WH PoE Power Transformers ST1336WH SPEC EP13 Series12W12V0.41A~1.0A

How to select

How to select a PoE power transformer

The converter decides, not the network port. Settle the power stage first, then let output, core size and the datasheet narrow the candidates.

  1. 01

    Locate the power stage

    Confirm the part sits in the isolated DC-DC stage behind the PD controller, not on the Ethernet data path. Note the PoE type, the input range at the converter and any adapter input.

  2. 02

    Define rails, load and topology

    List each output rail with continuous and peak current, any auxiliary winding for controller bias, the switching frequency and whether the design is flyback, forward or active clamp.

  3. 03

    Shortlist by power, voltage and core

    Use the power, output voltage and current filters, then compare primary inductance, leakage inductance, DCR, turns ratio and the hipot condition in each PoE transformer datasheet.

  4. 04

    Prove it on the board

    Build samples into the real converter and check efficiency, temperature rise, saturation margin and EMI before release. A known part number can go straight to a sample or price request.

Key selection parameters

PoE transformer filters and what they tell you

These four filters come from each part's catalog record. They shortlist candidates; the converter conditions behind every number are in the datasheet.

01

Package size (EP / EFD)

EP7, EP10 and EP13 parts are EP transformer cores; EFD15, EFD20 and EFD25 are EFD transformer cores. The name sets the core family, not mounting, height or pin layout. If you need an SMD power transformer, confirm the mounting style in each drawing.

02

Power (W)

A reference output power under stated conditions, from 3 W to 100 W across the range. It is not a PoE class label and holds only for the converter conditions given in the datasheet.

03

Output voltage (V)

The rail the winding was designed for, such as 3.3 V, 5 V, 12 V or 24 V. The transformer does not regulate; the controller and its feedback loop set the final output.

04

Output current (A)

Some entries are exact values, others are bands such as 1.08 A to 1.99 A or ≥ 2 A. A band is not an upper limit, so read the rated current in the datasheet before calculating power.

Product family comparison

EP and EFD PoE transformer series compared

Each row sums up one EP or EFD series and the power, voltage and current values that appear in it. Use it to pick a core size, then open individual parts, since one series can hold very different outputs.

Return to the selector ↑
Package SizePartsPower (W)Output Voltage (V)Output Current (A)Action
EP7 Series610W, 12W, 15W, 3W5V, 12V, 13V0.41A~1.0A, 1.08A~1.99A, ≥ 2A, 0.25AFilter →
EP10 Series115W, 6W, 7W, 10W, 12W5V, 12V, 13.5V0.41A~1.0A, ≥ 2AFilter →
EP13 Series2510W, 12W, 13W, 14W, 18W, 20W, 24W, 25W, 25.2W, 30W5V, 12V, 13.4V, 13.5V, 13V, 14V, 24V0.41A~1.0A, 1.08A~1.99A, ≥ 2A, 5AFilter →
EFD15 Series410W, 13W3.3V, 5V, 12V, 24V0.41A~1.0A, 1.08A~1.99A, ≥ 2A, 3AFilter →
EFD20 Series530W, 60W, 100W5V, 12V, 24V1.08A~1.99A, ≥ 2A, 8.35AFilter →
EFD25 Series445W, 60W, 72W, 90W12V, 15V, 24V≥ 2A, 3A, 3.75AFilter →

Technical performance & application fit

PoE power transformer fit by powered device

When you choose a PoE transformer for PD supplies, the load decides, not the network speed. These notes cover what to settle first in common PoE terminals; they are review prompts, not suitability claims for any listed part.

Application review

IP camera PD supplies

  • List the main rails and the startup load, including IR illumination, heaters or pan/tilt motors.
  • PTZ models with heaters can exceed PoE+ power; an 802.3bt PoE transformer is then sized for the Type 3 or Type 4 budget after conversion loss.
  • Check peak current against the saturation margin of the candidate core.
Application review

Wireless AP PD supplies

  • Give system consumption, startup behaviour, supply rails and enclosure cooling.
  • Multi-radio access points often need PoE+; an 802.3at PoE transformer then works within 25.5 W at the PD input, less conversion loss.
  • Wi-Fi generation or Ethernet speed does not replace a power budget.
Application review

VoIP phones and other PoE terminals

  • Many desk phones fit within the 802.3af budget of about 13 W at the PD; size an 802.3af PoE transformer from the actual rails, not the class name.
  • Note available height, since low-profile housings limit the core size.
  • If the design uses a non-isolated supply or a complete PD module, first confirm a separate transformer is needed.
Get technical support →

Downloads & technical resources

PoE transformer datasheet, 3D model and footprint

Enter all or part of a part number and the PoE transformer datasheet, STEP model and PCB footprint open from one row. Lay out the converter from the winding diagram and pin table in that datasheet.

55
PDF datasheets listed
55
3D file sets listed
54
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Category overview

PoE power transformers and where they fit

A PoE power transformer, sometimes searched as a power over Ethernet transformer, is not the same part as a PoE-capable LAN transformer. Mixing the two up is the most common error in this category.

01

Data side or power side

Search for a PoE Ethernet transformer and you will find two different parts. On the data side, the LAN transformer couples the signal and lets DC current flow through its center taps; Ethernet transformer PoE ratings such as PoE+ or 4PPoE describe that current and nothing more.

On the power side, the PoE power transformer sits in the isolated DC-DC converter of the powered device and turns the nominal 48 V input into the rails the electronics use. This page covers that part, which engineers also call a PoE PD transformer or simply PoE magnetics.

02

Choose against the converter, not the port

Because it belongs to the power stage, a PoE transformer is chosen against the converter: the input range behind the PD controller, output voltage and current, switching frequency, topology and the isolation the safety case requires. The PoE class sets the budget, but two PDs of the same class can need different DC-DC transformer designs.

Most low and mid-power PD supplies use a flyback transformer, while some higher-power 802.3bt designs move to an active clamp forward converter. Confirm the intended topology in the datasheet before treating a part as a flyback transformer for PoE.

03

Core size follows output power

EP and EFD describe core shapes, and each size covers a power range. In the current data, EP7 and EP10 parts carry power references up to 15 W, EP13 parts up to 30 W, and EFD20 and EFD25 parts from 30 W to 100 W. A larger core gives more winding window and lower loss at higher current, at the cost of board area and height.

Pick from output power and available space, then check temperature rise and saturation margin on the real board.

FAQ & related guides

PoE power transformer questions before layout

Answers on topology, PoE class, winding ratios, isolation and samples. Treat them as review guidance and confirm values in each datasheet.

Can a PoE power transformer replace a PoE-capable LAN transformer?

No. The LAN transformer carries Ethernet data and lets DC current pass through its center taps; the PoE power transformer sits in the DC-DC stage and converts that power. Their windings, inductance and design targets are unrelated. Identify where the part sits in the schematic first, then select from the matching category.

Is a PoE+ transformer different from a PoE++ transformer?

Only in the power it is designed for. PoE+ (IEEE 802.3at) allows up to 25.5 W at the PD input, while PoE++ (802.3bt) allows up to 51 W for Type 3 and 71.3 W for Type 4. The transformer is then chosen for the converter output at that power, so compare the catalog power reference with your rails after conversion loss.

Are all PoE power transformers flyback transformers?

No. A PoE flyback transformer is the usual choice for PD supplies up to the mid-power range, but forward and active clamp designs are also used, mostly at higher power. The selector has no topology filter, so check the application circuit in each datasheet, or tell us your controller and topology and our FAE team will suggest suitable parts.

Do you list an active clamp forward transformer for high-power PDs?

Check part by part. The catalog is organised by core size and output rather than topology. If your 802.3bt design uses an active clamp forward converter, send the controller, input range, output rails and switching frequency; FAE will say whether a listed part fits or a custom design should be evaluated.

Does the turns ratio fix the output voltage?

Not on its own. In a flyback the output depends on the ratio, the duty cycle and the controller's feedback, and the auxiliary winding and pin definitions also matter. Shortlist with the output voltage filter, then check every winding in the PoE transformer datasheet. A ratio is not a regulated input-to-output voltage guarantee.

Is the hipot test voltage a working-voltage rating?

No. The hipot figure is a short withstand test between stated windings, with its own AC or DC type and duration. Working insulation depends on the safety standard, creepage and the full board design. If the project needs specific compliance documents, name the standard and the part number and your sales engineer will confirm what can be supplied.

What should I send for a replacement assessment?

The original part number and datasheet revision, input range, output rails and load, controller and topology, and any fixed footprint or height limit. Incomplete data is fine for a first review. FAE compares candidates and lists what needs validating; there is no automatic replacement result, and the final choice is proven in your circuit.

Who makes VOOHU PoE transformers, and how are samples requested?

VOOHU is a PoE transformer manufacturer and winds these parts in its own magnetics plant in Mianyang, China. Request samples from the product table, or email the part number with quantity and delivery country. Samples are available for evaluation and selected parts are free of charge, with the options confirmed by our FAE team. Quotes and lead times are set for each order.

Engineer support

Continue after product selection

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.