Contact count
Eight for RJ45, four or six for RJ11. The housings differ in width and keying, so an RJ11 plug fits an RJ45 jack but not the reverse.
I/O Connector products
Low height housings reduce the clearance needed above the board, for slim enclosures and stacked assemblies where a standard jack will not fit. Confirm the panel cutout position moves with the body height before finalising the enclosure.
Part number search & selector
The table uses the current English-site product records, published selection fields and part-specific technical-file links.
* Frozen Image and Part Number columns · drag horizontally to review all specifications
| Image | Part number | Datasheet | Compare | Downloads | Category | Connector Type | Ports | Tab | Integrated Connector Modules | Data Rate | PoE | LED | Mounting Method | Shield Tabs | EMI / Gasket | Operating Temperature | Sample |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SYT811Q002GWA2DB057 | SPEC | RJ45(Low Height) | 90° | 1 x 1 | Up | YES | 10G Base-T | Non-PoE | NO LED | DIP | YES | NO | -40 to +85°C |
|
||
|
SYT1611Q002FF3A10DC057 | SPEC | RJ45(Low Height) | 90° | 1 x 1 | Down | YES | 10G Base-T | Non-PoE | YG/G | DIP | YES | YES | -40 to +85°C |
|
||
|
SYT1611Q002FF3A2DC5057 | SPEC | RJ45(Low Height) | 90° | 1 x 1 | Down | YES | 5G Base-T | Non-PoE | YG/G | DIP | YES | YES | -40 to +85°C |
|
||
|
SYT1511Q153CF5W7CBD057 | SPEC | RJ45(Low Height) | 90° | 1 x 1 | Up | YES | 100/1000M | Non-PoE | GO/Y | DIP | YES | NO | -40 to +85°C |
|
||
|
SYT811Q112FN4A10D057 | SPEC | RJ45(Low Height) | 90° | 1 x 1 | Up | YES | 100/1000M | Non-PoE | OG/Y | DIP | YES | YES | -40 to +85°C |
|
||
|
SYT1211Q008FF1A10D057 | SPEC | RJ45(Low Height) | 90° | 1 x 1 | Down | YES | 100/1000M | Non-PoE | GY/Y | DIP | YES | YES | -40 to +85°C |
|
||
|
SYT60S1188AB1A6DY1008 (bent foot) | SPEC | RJ45(Low Height) | 90° | 1 x 1 | Up | NO | ALL | ALL | Y/G | DIP | YES | NO | -40 to +85°C |
|
||
|
WH99TG-Q618G830415 | SPEC | RJ45(Low Height) | 90° | 1 x 1 | Up | YES | 100/1000M | Non-PoE | GO/Y | DIP | YES | YES | -40 to +85°C |
|
||
|
SYT811Q112CN4A10DB | SPEC | RJ45(Low Height) | 90° | 1 x 1 | Up | YES | 100/1000M | Non-PoE | OG/Y | DIP | YES | NO | -40 to +85°C |
|
Broaden the selected filters or clear the current search.
By type
RJ45, RJ11, offset and low height variants, combination housings and dust plugs.
How to select
Contact count, then orientation and height, then shielding, then magnetics.
RJ45 uses eight contacts for Ethernet, often written 8P8C. RJ11 uses four or six for telephony and low speed serial. They are not interchangeable.
Vertical, right angle or offset, depending on whether the cable enters the panel horizontally and where the board sits behind it.
Low height variants exist for slim assemblies. Confirm the clearance above the board as well as the panel cutout before selecting.
Shielded housings help emissions and need a defined chassis path. Integrated magnetics save board area but fix the transformer choice.
Parameters
Contact count and mounting orientation decide fit; shielding decides emissions.
Eight for RJ45, four or six for RJ11. The housings differ in width and keying, so an RJ11 plug fits an RJ45 jack but not the reverse.
Vertical, right angle or offset. Offset variants shift the opening relative to the board so the panel cutout can sit at a different height.
Through hole gives mechanical strength for repeated plugging. Surface mount suits automated assembly but usually needs additional retention.
Low profile variants reduce the clearance needed above the board. Confirm both the body height and the panel cutout position together.
A shielded housing gives the cable screen a path to chassis. It needs a defined ground connection on the board to be effective.
Some RJ45 housings contain the LAN transformer. That saves board area but fixes the magnetics specification inside the connector.
Compare
Contact count and mechanical keying separate what looks like one family.
Return to the selector ↑| Category | Parts | Connector Type | Ports | Tab | Integrated Connector Modules | Data Rate | PoE | LED | Mounting Method | Shield Tabs | EMI / Gasket | Operating Temperature | Action |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| RJ11 Connector | 37 | 90°, 180° | 1 x 1, 1 x 2, 1 x 4, 2 x 1 | Up/Down, up/down, Down, Up | NO | ALL | Non-PoE, ALL | NO LED | DIP | YES, NO | NO | -40 to +85°C | Filter → |
| RJ45 Connector | 627 | 45°, 90°, 180° | 1 x 1, 1 x 2, 1 x 3, 1 x 4, 1 x 5, 1 x 6, 1 x 8, 2 x 1, 2 x 2, 2 x 3, 2 x 4, 2 x 5, 2 x 6, 2 x 8 | Up/Down, up/down, Down, Up, Not specified | YES, NO | ALL, 10/100M, 100/1000M, 2.5G Base-T, 5G Base-T, 10G Base-T, 10/100M +SPD, 100/1000M +SPD | Non-PoE, 350mA, 600mA, 720mA, 900mA, 850mA, 1000mA, 1.5A, ALL, Not specified | NO LED, G/-, G/G, G/Y, G/O, G/GO, G/GY, GO/Y, GO/G, GY/Y, GY/G, GY/YG, GY/GY, GR/GG, GO/GO, GR/GR, GG/RG, OG/Y, Y/G, Y/GY, Y/GO, YG/G, YG/YG, -/G | DIP, SMD, Not specified | YES, NO | YES, NO | 0 to +70°C, -20 to +70°C, -40 to +85°C, -40 to +105°C | Filter → |
| RJ45 Offset Connector | 46 | 90° | 1 x 1, 1 x 4 | Down, Up | YES, NO | ALL, 10/100M, 100/1000M, 2.5G Base-T, 10G Base-T | Non-PoE, ALL | NO LED, G/Y, G/GY, GO/Y, GO/G, O/G, Y/G, Y/GO | DIP, SMD | YES, NO | YES, NO | 0 to +70°C, -40 to +85°C | Filter → |
| RJ45(Low Height) | 29 | 90° | 1 x 1 | Up/Down, Down, Up | YES, NO | ALL, 10/100M, 100/1000M, 5G Base-T, 10G Base-T | Non-PoE, ALL | NO LED, G/Y, GO/Y, GY/Y, GY/G, OG/Y, Y/G, YG/G | DIP | YES, NO | YES, NO | -40 to +85°C | Filter → |
| RJ45 Combination | 32 | 90° | 1 x 1 | Up | YES, NO | ALL, 10/100M, 100/1000M, 2.5G Base-T, 5G Base-T, 10G Base-T | Non-PoE, ALL | NO LED, G/Y, G/GY, GO/Y, GY/G, OG/Y, Y/G, Y/OG, Y/GO | DIP | YES | YES, NO | -40 to +85°C | Filter → |
| RJ45 Dust Plug | 2 | 180° | 1 x 1 | Not specified | NO | - | - | NO LED, - | Not specified | NO | NO | -10 to +85°C, Not specified | Filter → |
| RJ45 combined | 1 | 90° | 1 x 1 | Up | YES | Not specified | Non-PoE | G/Y | DIP | YES | YES | -40 to +85°C | Filter → |
Application review
Confirm the link speed, the panel arrangement and the height available on the board.
Documents
Drawings carry the footprint, panel cutout, retention and recommended hole sizes.
Showing representative available file sets. Search to find a specific SKU.
VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.
Category overview
These connectors look like one family, but contact count, shielding and integrated magnetics each change what the port can do.
Discuss a new design
Contact FAE for a replacement assessment.
Already have a part number? Request samples or a quote.
RJ45 carries eight contacts, often written 8P8C, and is the Ethernet connector. RJ11 carries four or six in a narrower housing for telephony and low speed serial. An RJ11 plug will physically enter an RJ45 jack because it is narrower, which is a frequent source of confusion, but an RJ45 plug will not fit an RJ11 jack.
A shielded housing gives the cable screen somewhere to terminate, which helps emissions and immunity. It only does that if the board provides a defined low impedance path from the housing to chassis. A shielded connector wired to a floating shell can perform worse than an unshielded one, so plan the ground path early.
An RJ45 with the LAN transformer built into the housing saves board area and shortens the differential routing, which helps signal integrity. The trade is that the magnetics are fixed inside the part: you cannot change the transformer without changing the connector, and the speed is set at selection time.
FAQ
Answers cover RJ45 against RJ11, shielding, magnetics and mounting choices.
The saving against a standard housing is stated on each drawing rather than being uniform across the range. Compare the body height dimension directly between the standard and low height part you are considering, and check it against the clearance the enclosure actually allows.
Yes, and this is the step most often missed. Reducing the body height moves the port opening relative to the board, so the panel aperture has to move with it. Check both the body height and the opening position on the drawing before the enclosure is tooled.
A smaller housing has less material to resist the force of repeated plugging and cable strain. If the port is user accessible and will be plugged often, check the retention features on the drawing and consider whether the design needs additional mechanical support.
Availability varies by part, because a lower body leaves less internal volume for magnetics in particular. Check the specific part number rather than assuming every option carries across from the standard range. Send your requirement if you need a particular combination.
With a complete part number, send the part number, quantity, delivery region and the date you need it. If you are still selecting, send the clearance available above the board, the panel aperture position and the expected mating cycles.
Engineer support
Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.
Include the document revision
Temperature, isolation voltage and PoE current basis
Pin count, pitch and spacing between pin rows
To help prioritize samples and evaluation
When you need candidates and a comparison of differences
Engineering review identifies candidate parts and explains the differences.
From the selector or engineering review
Prototyping / pilot build / production
Specify sample and production timing separately
Compliance documents, material declarations or third-party reports
Sample quantity, lead time and cost depend on the project stage and part number. Sales will respond on business days.