Skip to main content

CABLE CONTACTS AND PCB DESIGN

RJ45 pinout: cable colors and MagJack checks

An RJ45 pinout can mean the eight cable contacts or the solder pins of a PCB connector. T568A and T568B define cable wire colors; they do not define a MagJack footprint. Start with the cable table, then check the exact connector and PHY drawings.

T568A AND T568B

RJ45 wire colors by contact number

The table refers to the eight mating contacts, not a solder-side PCB view. Locate contact 1 using the connector drawing before reading left to right. Colors are written as text so the table does not depend on color vision. [1]

Eight cable contacts and their twisted-pair partners
Contact T568A color T568B color Contact pair
1 White / green White / orange 1–2
2 Green Orange 1–2
3 White / orange White / green 3–6
4 Blue Blue 4–5
5 White / blue White / blue 4–5
6 Orange Green 3–6
7 White / brown White / brown 7–8
8 Brown Brown 7–8

For a straight-through cable, keep the same termination scheme at both ends. T568A and T568B exchange the orange and green pairs. An A/B cable is not the same wire map as a straight-through A/A or B/B cable. [2]

ETHERNET DATA PAIRS

10/100 Ethernet and Gigabit use different pair counts

This comparison is for 10BASE-T, 100BASE-TX and 1000BASE-T data wiring. It is not a PoE power or polarity diagram. [3] [4]

Data pairs at the cable interface
Ethernet mode Data-contact pairs What to check
10BASE-T / 100BASE-TX 1–2 and 3–6 Two data pairs. Transmit / receive labels depend on the MDI or MDI-X port.
1000BASE-T 1–2, 3–6, 4–5 and 7–8 All four pairs carry data. Do not label 4–5 and 7–8 as universally unused.

BEFORE PCB LAYOUT

Read the MagJack circuit and footprint separately

TI's magnetics example distinguishes PHY signals, transformer windings, center taps and cable-side contacts. It does not provide the PCB pin numbers for every RJ45 connector. Use the selected part's own drawing for that mapping. [4]

  • Confirm the drawing view

    Check whether the drawing shows the mating face, component side or PCB solder side. Use its contact numbering; a mirrored view can reverse the apparent order.

  • Trace contacts to PCB pins

    Separate the cable-side contact numbers from the PCB terminal numbers. With integrated magnetics, follow the internal schematic through the transformer rather than joining equal numbers by assumption.

  • Check LEDs, center taps and shield tabs

    Read these terminals from the selected part drawing. Confirm LED polarity and the PHY circuit requirements. Keep shield tabs and center taps distinct from Ethernet signal contacts.

  • Check the complete port requirement

    Record the PHY part number, Ethernet mode, PoE requirement and connector part number. Compare the approved schematic and footprint before ordering samples or releasing the PCB.

Common RJ45 pinout questions

  • What changes between T568A and T568B?

    The green and orange pairs exchange positions: contacts 1–2 and 3–6. The blue pair at 4–5 and brown pair at 7–8 stay in place.

  • Can a cable color chart define a MagJack PCB footprint?

    No. A cable chart identifies the eight mating contacts. The connector drawing defines the PCB terminals, internal magnetics, LED terminals and shield tabs for that exact part.

  • Can I use the same numbered pin on two different connectors?

    Do not assume that equal numbers mean equal functions. Compare the mating contacts, internal circuit, PCB terminal functions and mechanical drawing for both part numbers.

Sources and scope

Prepared with AI assistance from the manufacturer references below. Source check: . This is a general wiring reference; it is not an approval of a product-specific schematic or footprint.

  1. Belden — Copper Structured Cabling Design Guide, Issue 10
    Printed page 22, Figure 14 and Table 2: T568A / T568B colors and drawing orientation.
  2. Fluke Networks — Differences Between Wiring Codes T568A vs T568B
    Orange / green pair exchange and consistent termination choice.
  3. Cisco — Specifications for Ethernet 100BaseTX and 10BaseT Cables
    Data contacts and straight-through / crossover wiring examples.
  4. Texas Instruments — DP83867E / IS / CS datasheet, Rev. G
    Figure 9-2, printed page 109: four cable-side pairs, PHY-side magnetics and center taps. This example is not a universal connector pinout.

Have a connector part number or port design?

Browse RJ45 connectors and MagJacks or LAN transformers. Include the exact part number, PHY, data rate, PoE requirement and drawing revision in your inquiry.