Conversion type: F/F, F/M or pin
An F/F body is a bulkhead RJ45 that takes a patch cable on both sides; F/M and F/M (Pin) terminate inside the enclosure. Match it to the wiring drawing first.
I/O Connector products
Choose a protected Ethernet interface for your equipment. Compare waterproof RJ45 connectors by panel mounting, orientation, front/rear interface and part-specific ingress rating. Review the required seals and installation drawing, then request samples, pricing or a replacement assessment.
Part number search & selector
The table uses the current English-site product records, published selection fields and part-specific technical-file links.
* Frozen Image and Part Number columns · drag horizontally to review all specifications
| Image | Part number | Datasheet | Compare | Downloads | Docking Type | Docking angle | Number of pins | Conversion Type | Installation Type | Waterproof grade | Panel thickness MAX (mm) | Rated voltage (V) | Rated current (A) | Contact resistance MAX (mΩ) | Insulation resistance MIN (MΩ@500V DC) | Compressive strength | MIN number of plug-in cycles | Operating temperature (°C) | Sample |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
WHPMWRJ5004 | SPEC | - | 180° | 8P8C | F/F | - | IP67 | - | 125 | 1.5 | 30 | - | 1min@1000V AC | - | - |
|
Broaden the selected filters or clear the current search.
Is this another brand's part number? Find the VOOHU replacement →
Product family quick links
Part counts by docking angle come from the current product records; straight 180° bodies make up most of the waterproof RJ45 range.
How to select
Work from the enclosure wall inward: what has to pass through it, how the waterproof RJ45 port seals, what the panel drawing allows and how the mated assembly behaves where it is finally installed.
Decide between a female-to-female bulkhead for patch leads, a female-to-male pass-through or a pin-header version wired to an internal board, and note where service access sits.
An IP67 grade on a waterproof RJ45 holds only with the specified plug fully mated or the dust cap fitted, and with the gasket seated. Check all three in the part drawing.
An RJ45 panel mount seal depends on the cutout, the maximum wall thickness (3 mm or 4 mm where published), the nut thread and the tightening space.
Test the mated waterproof RJ45 assembly at its installed orientation, temperature and exposure, or send a known part number to sales for samples and pricing.
Key selection parameters
Each selector column answers one sealing or electrical question. A blank cell means the value is not published for that part number, not that the waterproof RJ45 passes it.
An F/F body is a bulkhead RJ45 that takes a patch cable on both sides; F/M and F/M (Pin) terminate inside the enclosure. Match it to the wiring drawing first.
Published grades for this waterproof RJ45 range are IP65 and IP67. A blank grade is unconfirmed, and no grade applies to an open port without its cap.
For a waterproof RJ45 panel mount, the maximum wall thickness sets how much thread remains for nut and gasket. A thicker or curved wall can leave the seal uncompressed.
180° bodies pass straight through the wall; a 90° waterproof RJ45 turns the cable along the panel where outside depth is limited.
Rated voltage and current, contact and insulation resistance, withstand voltage and minimum mating cycles (750 where stated) are separate values with their own test conditions.
Product family comparison
Every listed waterproof RJ45 body uses a full-thread (Full Teeth) panel nut; the real split is a straight 180° exit against a 90° exit along the wall. Grades, panel thickness and electrical values change row by row, so filter here and then read the individual part line.
Return to the selector ↑| Docking Type | Parts | Docking angle | Number of pins | Conversion Type | Installation Type | Waterproof grade | Panel thickness MAX (mm) | Rated voltage (V) | Rated current (A) | Contact resistance MAX (mΩ) | Insulation resistance MIN (MΩ@500V DC) | Compressive strength | MIN number of plug-in cycles | Operating temperature (°C) | Action |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Full Teeth | 17 | 90°, 180° | 8P8C, 8P10C, -, Not specified | F/F, F/M, F/M(Pin), - | Panel Type, - | IP65, IP67, - | 3, 4, - | 5, 125, 300, - | 1, 1.5, - | 5, 30, 2000, - | 10, 20, 500, 1000, - | 1min@1000V AC, 1min@ 500V AC, 10ms@300V dc, -, Not specified | 750, -, Not specified | -40℃~85℃, -30℃~80℃, -25℃~60℃, - | Filter → |
| - | 1 | 180° | 8P8C | F/F | - | IP67 | - | 125 | 1.5 | 30 | - | 1min@1000V AC | - | - | Filter → |
Technical performance & application fit
Outdoor cabinets and factory machines stress a waterproof RJ45 in different ways. Send the exposure, the panel and the cable, and the review covers the whole installed assembly instead of the connector body alone.
Downloads & technical resources
Type a full or partial part number to open its PDF datasheet or 3D model. Most parts are panel feedthroughs, so PCB footprints are rarely listed; ask for the board pattern if you use a pin-header version.
Showing representative available file sets. Search to find a specific SKU.
VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.
Category overview
Ingress ratings get the attention, but the first question is which kind of waterproof Ethernet connector the enclosure needs, and the second is how it will be installed.
The range covers bulkhead RJ45 adapters with a full-thread body, female-to-female versions that take a patch lead on each side, RJ45-to-pin-header adapters for internal wiring, sealing caps for unused ports and made-up cable assemblies. Most of them are a panel mount RJ45 connector fixed through the wall on that threaded body, with 8P8C contacts and a few 8P10C versions.
These parts solve different problems. A bulkhead feedthrough lets a field cable reach equipment without opening the enclosure, while a pin-header adapter brings the contacts straight to an internal harness. Decide which kind of waterproof RJ45 the enclosure needs before comparing ingress ratings.
An ingress rating such as IP67 describes the waterproof RJ45 correctly mounted, correctly mated and with its gasket or O-ring seated on a flat panel inside the stated thickness range. An open port, an over-thick wall, a burred panel cutout or a cable outside the gland range each break it.
The grades published on this page are IP65 and IP67. IP65 covers dust and water jets, IP67 adds temporary immersion, and an IP68 RJ45 rating needs an immersion depth and duration stated by the manufacturer. Treat the rating as a property of the installation, not of the part alone.
Some waterproof RJ45 parts are specified for Cat6 or Cat6A and several carry an industrial temperature range of -40 °C to +85 °C. The category caps the link the assembly can support, and the temperature range decides whether the seal material stays serviceable where the equipment is actually installed.
For an outdoor RJ45 connector, UV, salt spray, ice and repeated thermal cycling age the gasket faster than rain does. The IP code says nothing about those, so ask for evidence against the real exposure instead of reading it from the rating.
FAQ & related guides
Answers on IP grades, panel cutouts, caps, M12 and cable seals. The limits for any single waterproof RJ45 part number still come from its own datasheet.
Only with the specified mating plug fully engaged, or the protective cap fitted on an unmated port, the gasket or O-ring seated and the panel within the stated thickness. IP67 is published here for several 180° and 90° full-thread bodies, but some rows leave the grade blank, so check the exact part line.
Under IEC 60529, IP65 means dust-tight and protected against water jets, IP67 adds temporary immersion (typically 1 m for 30 minutes), and IP68 covers immersion beyond that under conditions the manufacturer states. The grades published on this page are IP65 and IP67. If a specification asks for an IP68 RJ45 port, send the depth and duration for review rather than treating IP67 as equivalent.
The cutout shape and size, wall thickness, flatness and finish of the seal face, nut and tightening access, and clearance inside and outside. Waterproof RJ45 parts that publish a limit allow a maximum panel thickness of 3 mm or 4 mm; a thicker wall may need a different body rather than a thinner gasket.
In practice yes: both describe the receptacle side a plug mates into. A waterproof RJ45 female connector on this page is usually a female-to-female bulkhead, so a cable plugs in from each side, while the F/M and pin versions are female outside and terminate to a plug or pins inside.
M12 connectors, D-coded for 100 Mbit/s or X-coded for up to 10 Gbit/s, are common in machine building and seal by design. A waterproof RJ45 keeps the familiar RJ45 interface, so ordinary patch leads and test equipment still fit once the cap is off. If your customer or industry standard calls for M12, these parts are not a substitute for it.
No. The IP code covers dust and water only. UV, salt spray, chemicals, ice and long immersion have to be assessed separately against the seal and housing materials. For a port on a pole or rooftop cabinet, send the exposure profile and ask for supporting evidence before release.
Compare front and rear position, panel cutout and thickness, nut access, cable bend room, wiring and sealing. Orientation changes how the cable leaves the wall, which can change the routing inside and the side load on the seal.
Send the part number, the mating accessories you need such as caps or plug shells, quantity, destination and timing. If no part is chosen yet, share the enclosure drawing and protection requirement so our FAE team can propose candidates and explain the differences.
Engineer support
Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.
Include the document revision
Temperature, isolation voltage and PoE current basis
Pin count, pitch and spacing between pin rows
To help prioritize samples and evaluation
When you need candidates and a comparison of differences
Engineering review identifies candidate parts and explains the differences.
From the selector or engineering review
Prototyping / pilot build / production
Specify sample and production timing separately
Compliance documents, material declarations or third-party reports
Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.