VOOHU Push-Pull Transformers products

Transformers

Push-Pull Transformers

Find a push-pull transformer for your isolated power design. Compare six series against your input/output requirements, drive conditions and winding arrangement, using part-specific datasheets for selection and sample validation. Already have a part number? Request samples or pricing directly. For a new design, share your requirements. For an existing component, your sales engineer can coordinate an FAE replacement assessment.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

  • Own factories: connectors in Dongguan, magnetics in Mianyang
  • 1,500+ customers, including 150+ listed companies
  • ISO 9001 and ISO 14001 certified
  • Certificates and test reports →

Part number search & selector

Find Push-Pull Transformers part numbers

The table uses the current English-site product records, published selection fields and part-specific technical-file links.

* Frozen Image and Part Number columns · drag horizontally to review all specifications

Push-Pull Transformers product selection results
Image Part number Datasheet Compare Downloads SeriesL(μH)Turns RatioDCR1(mΩ)DCR2(mΩ)Isolation(VAC)Operating Temperature(℃) Sample
VOOHU WHST08003R0 Push-Pull Transformers WHST08003R0 SPEC WHST080801:22503504200-40℃ to 125℃
VOOHU WHST08001R0 Push-Pull Transformers WHST08001R0 SPEC WHST0801003:42502504200-40℃ to 125℃

How to select

Push-pull transformer selection for isolated supplies

Start from the rail you need on the isolated side and the driver that will switch the primary; the push-pull transformer choice follows from both.

  1. 01

    Define the isolated rail

    Record input range, output voltage, continuous load, startup current, available height and ambient temperature. A 5V to 5V isolated transformer and a 5 V to 15 V rail need very different ratios.

  2. 02

    Match the driver

    Identify the driver IC, for example an SN6501 or SN6505 class device, or a discrete driver stage. Note its switching frequency, then check the center tap arrangement and pins of each push-pull transformer candidate.

  3. 03

    Compare electrical and mechanical data

    Review isolation test voltage, inductance, DCR, leakage inductance and package, and confirm the volt-second capability against the voltage and on-time the driver applies.

  4. 04

    Validate and source

    Check document revisions and test push-pull transformer samples at full load and temperature. With a part number already chosen, ask for pricing directly; a replacement project goes through an FAE comparison first.

Key selection parameters

Push-pull transformer parameters: ratio, L, DCR, isolation

Seven columns describe each push-pull transformer in the table. Use them to shortlist, then confirm the test conditions in the push-pull transformer datasheet.

01

Turns ratio and center taps

Step-up ratios up to 1:3, step-down ratios such as 2:1 and 4:1, and multi-winding parts such as 1:1:0.45:0.45 are listed. Identify which push-pull transformer pins each ratio refers to; the ratio alone does not set a regulated output voltage.

02

Inductance

Primary inductance runs from 86 µH to 680 µH in the table. Check the measurement frequency and voltage, since similar values can come from different test conditions, and inductance sets the magnetising current at a given frequency.

03

DCR and leakage inductance

DCR1 and DCR2 are winding resistances in mΩ, typically primary and secondary; check which winding each refers to. With leakage inductance they shape regulation and loss, but they do not establish power or temperature rise on their own.

04

Isolation test voltage

Listed in VAC (Vrms) from 2100 to 4200. It is a hipot withstand test with its own duration and tested pins, not a continuous working voltage or an insulation class such as reinforced insulation.

05

Volt-second capability

The volt-second product a push-pull transformer winding can take before the core saturates. Compare it with the maximum input voltage multiplied by the on-time of each half cycle; at a lower switching frequency the margin shrinks.

06

Pins, package and temperature

Check polarity dots, center taps, dimensions and land pattern. Parts in the table list −40 to 125 °C operation; confirm the temperature rise of the isolated power transformer inside your enclosure.

Product family comparison

Push-pull transformer series at a glance

One row per WHST series of isolated DC-DC transformers, listing the inductance, ratio, DCR and isolation values found in it. Use it to choose a series, then confirm the exact part, because series membership does not fix the ratio.

Return to the selector ↑
SeriesPartsL(μH)Turns RatioDCR1(mΩ)DCR2(mΩ)Isolation(VAC)Operating Temperature(℃)Action
WHST06E64751:1.1, 1:1.3, 1:1.5, 1:1.7, 1:2100010003000, 3100-40℃ to 125℃Filter →
WHST06D7100, 200, 538, 600, 6801:1.07, 1:1:3.4, 1.2:1, 1.75:1, 3:4, 3:8, 4:1237, 250, 280, 350, 40070, 125, 220, 290, 520, 882, 9002500, 3000, 4000-40℃ to 125℃Filter →
WHST06K23401:2, 1:37501300, 15004000-40℃ to 125℃Filter →
WHST06Q286, 3501:1.2, 1:2.88100, 400500, 5202500, 4000-40℃ to 125℃Filter →
WHST06018340, 538, 6801:1, 1:1.7, 1:2, 2:1, 3:4, 3:5, 3:8, 4:3, 8:3, 8:9700, 750, 900, 1300, 1500700, 750, 900, 1000, 1200, 1300, 15004000-40℃ to 125℃Filter →
WHST08815371:1:0.45:0.456603302100-40℃ to 125℃Filter →
WHST080280, 1001:2, 3:4250250, 3504200-40℃ to 125℃Filter →

Technical performance & application fit

Push-pull transformers in isolated power rails

Most push-pull transformer designs supply a small isolated rail next to an interface or a driver. Each card names the first questions to answer; it is guidance and does not mean a listed part has been checked in your circuit.

Application review

RS-485 and CAN interface isolated power

  • A push-pull transformer for isolated RS-485 feeds the transceiver's isolated side; the data itself does not pass through it.
  • The same holds for a push-pull transformer for CAN: define isolated-side voltage, loads, startup current and the isolation boundary.
  • A 5 V to 5 V rail usually needs a ratio slightly above 1:1 to cover rectifier and regulator drop; confirm the loaded output in your circuit.
Application review

Industrial control auxiliary power

  • An isolated bias supply for sensors, ADCs or relay drivers often needs more than one rail, and a multi-winding push-pull transformer can cover several.
  • Share input range, output rails and loads, ambient conditions and available space.
  • Check board creepage against the isolation the product standard requires.
Application review

Gate-driver power supplies

  • A push-pull transformer for gate driver rails, such as the positive and negative supplies of an IGBT or SiC stage, is chosen by ratio, isolation and barrier capacitance.
  • Provide the driver part number, required rails and load, and the isolation requirement.
  • Gate driver power at high dv/dt also needs an isolation transformer with low inter-winding capacitance; ask for the value if the datasheet does not give it.
Get technical support →

Downloads & technical resources

Push-pull transformer datasheet and layout files

Enter a WHST part number, or just its first characters, to pull up the push-pull transformer datasheet with matching 3D and PCB files. Polarity dots and center tap pins are shown in the winding diagram.

38
PDF datasheets listed
36
3D file sets listed
28
PCB footprints listed

VOOHU’s published product content is reviewed by its engineering team. Specifications, downloads and technical support information are tied to specific part numbers, so you can verify them before requesting samples or a quotation.

Category overview

Push-pull transformers in isolated DC-DC stages

These parts sit inside an isolated converter, which is what separates a push-pull transformer from a complete isolated power supply module.

01

A component, not a module

A push-pull transformer provides the magnetic coupling and the isolation barrier in a push-pull converter, so catalogs also list it as an isolated DC-DC transformer, a DC-DC isolation transformer or simply an isolated power transformer.

It is not a finished module: there is no driver, no rectifier and no regulation inside. If you need a complete isolated power supply, buy a module; if you are designing the converter, this is the part.

02

Turns ratio sets the output

The primary of a center-tapped transformer is switched alternately from each end, so each half of the winding sees the input voltage in turn. The ratio between primary and secondary, together with the input voltage and the rectifier, sets the output before regulation. A push-pull transformer with several secondaries has a ratio for each; read each one from the datasheet rather than inferring it from the part number.

That symmetric drive resets the core every cycle, which is why a push-pull isolation transformer needs no separate reset winding.

03

Inductance, frequency and volt-seconds

Primary inductance, switching frequency and input voltage together decide how far the core is driven each half cycle. Run a push-pull transformer below its intended frequency and the volt-second stress rises toward saturation. Confirm the frequency range in the datasheet and check flux margin at maximum input voltage and lowest frequency.

Integrated drivers such as the SN6501 switch at a frequency fixed by the IC, so an SN6501 transformer is designed around that frequency and the driver's input voltage. A push-pull transformer designed for another driver may not have the same margin.

FAQ & related guides

Push-pull transformer FAQ: drivers, ratios and isolation

Answers on modules, center taps, drivers, isolation ratings and samples. Exact limits for each part number sit in its own documents.

How does a push-pull transformer differ from an isolated DC-DC module?

The push-pull transformer is one magnetic part, used with a driver, a rectifier and any regulation you add, while a module contains all of those. Select the isolated DC-DC transformer from input, output, driver and isolation requirements rather than the target output voltage alone, and share the reference circuit if the supply is already defined.

How should I read the ratio of a center-tapped push-pull transformer?

CT means center tap: the primary of a center-tapped transformer is split into two halves. Find the winding diagram, identify the full and half winding sections and the polarity dots, and match them to the driver's switch pins. Ratio notation varies between documents, so an abbreviated value in the table does not replace the pin check.

Which push-pull transformer for SN6501 or SN6505 drivers?

Match the driver's input voltage, switching frequency and current limit to the push-pull transformer's volt-second rating, ratio and isolation, then check the output under load. We do not state that every part suits these drivers; send the driver, input and output rails, and FAE will suggest candidates for evaluation.

Do the input voltage and turns ratio determine the actual output voltage?

Not by themselves. Rectifier drop, winding resistance, any regulator and the load all move the result. Share the input range, required output voltage and current and the driver circuit so engineering can assess candidates, then check loaded output and startup in your own circuit.

Does a 3000 VAC or 4000 VAC isolation rating define continuous operating voltage?

No. Read the isolation test voltage with its duration, AC or DC type and tested pins. It is not a continuous working voltage and not proof of basic or reinforced insulation. Define the working voltage and insulation class separately, then confirm them against the datasheet and with our engineers.

What should I provide for RS-485/CAN, auxiliary or gate-driver power selection?

Start with the application, input range, output voltage and load, then add the driver, isolation requirement and space limits. For RS-485 or CAN, list the isolated-side loads; for several auxiliary rails, explain how they connect; for gate-driver supplies, give the positive and negative rails. Two designs with the same application name can still need a different push-pull transformer.

Can VOOHU suggest a replacement for another manufacturer's part?

Yes, through an engineering review. Send the complete original part number, datasheet revision, circuit and any fixed mechanical limits; FAE compares candidates and lists the differences. Similar table values do not make one push-pull transformer a drop-in replacement for another, so electrical, thermal and layout validation is still required.

How do I request samples, pricing or a custom ratio?

For a known part, send the full number, quantity, project stage and destination; no separate selection step is needed for pricing. Samples are available for evaluation and selected parts are free of charge; our FAE team will gladly confirm which ones apply. Custom ratios or packages are assessed from input and output, driver, isolation and size requirements, with design, cost and timing confirmed after review. VOOHU produces each push-pull transformer in its own magnetics factory in Mianyang.

Engineer support

Continue after product selection

Send the candidate part number and the condition you need reviewed. Sample support can be added after the selection is clear; commercial questions may be discussed in the same engineering conversation.

  1. 1Selected part numbers
  2. 2Engineering review
  3. 3Sample request
  4. 4Commercial discussion

For a replacement review

  • Original part and datasheet

    Include the document revision

  • Operating conditions

    Temperature, isolation voltage and PoE current basis

  • Package constraints

    Pin count, pitch and spacing between pin rows

  • Project stage and annual volume

    To help prioritize samples and evaluation

  • Target review date

    When you need candidates and a comparison of differences

Engineering review identifies candidate parts and explains the differences.

For samples and a quotation

  • Candidate part numbers

    From the selector or engineering review

  • Quantity and project stage

    Prototyping / pilot build / production

  • Required delivery date

    Specify sample and production timing separately

  • Required documentation

    Compliance documents, material declarations or third-party reports

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Sales will respond on business days.

For OEM and volume orders. MOQ is one full reel, tray or tube per part.

Your information will be used only to respond to this support request.

Parameter comparison

Compare selected part numbers

Differences are presented for review; confirm final values and file revisions in each part-specific datasheet.