Skip to main content
SYT211B083DB1A7CBS057 90° side insertion 1*1 Tab UP Y/G 10/100M SMT RJ45
Homepage   /   Products
Network Connector (RJ45/RJ11)

SYT211B083DB1A7CBS057 RJ45 MagJack

Single-port right-angle shielded RJ45 jack: tab up, yellow / green LEDs, surface-mount (SMT), shield tabs, integrated Ethernet magnetics (MagJack). Rated −40 to +85 °C.

Orientation
90° (right angle)
Ports
1 × 1
Tab
Up
LED
Yellow / Green
Integrated magnetics
Yes
Operating temperature
−40 to +85 °C
SYT211B083DB1A7CBS057 Network Connector (RJ45/RJ11) perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number SYT211B083DB1A7CBS057 is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 3865 5578
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

01Specifications

SYT211B083DB1A7CBS057 specifications

ParameterValue
Orientation 90° (right angle)
Ports 1 × 1
Tab Up
LED Yellow / Green
Integrated magnetics Yes
Data rate 10/100BASE-TX
PoE Not PoE rated
Mounting SMT
Shield tabs Yes
EMI gasket Yes
Operating temperature −40 to +85 °C

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

SYT211B083DB1A7CBS057Need samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where SYT211B083DB1A7CBS057 is used

  • Switches and routers
  • Industrial controllers
  • IP cameras and NVRs
  • Embedded boards

Typical application

Ethernet PHYSYT211B083DB1A7CBS057RJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The jack integrates the Ethernet magnetics: the PHY connects to it directly, and the transformer and common-mode termination sit inside the jack.

Check the datasheet for the centre-tap wiring your PHY needs and match the LED pins to the PHY's LED outputs.

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Check tab orientation and LED positions against the enclosure opening.Tab Up / Tab Down and LED placement are the most common selection errors for RJ45 jacks.Check my layout →
  2. 02Bond the shield to chassis ground according to your grounding scheme.A floating or poorly bonded shield can make radiated emissions worse.EMC troubleshooting →
  3. 03For PoE or isolation, the magnetics decide — not the jack.A jack without magnetics provides neither PoE nor isolation by itself; choose a PoE-rated LAN transformer or a jack with integrated PoE magnetics.See LAN transformers →

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

SYT211B083DB1A7CBS057Not sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • SYT211B083DB1A7CBS057 Datasheet (PDF)2026-01-13 · This part Download ↓
  • 3D model (STEP)2026-06-26 · This part Download ↓
  • RJ45 Connector Reliability TestLatest · Product family View →
  • RJ45 EU RoHS ReportLatest · Product family View →
  • REACH SVHC test reportLatest · Communication electronic components View →
SYT211B083DB1A7CBS057Need another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Test report Test report · RJ45 connectors EU RoHSNo. WTH26H08256842R1C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-09-24
WTH26H08256842R1C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-09-24 RJ45 connectors View PDF →
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF →
Test report Test report · Product family Reliability test report
— — — Product family View PDF →

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples →

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter SYT211B083DB1A7CBS057This part SYT211B035HWA4D SYT211B227DC1A7CBS057
Orientation 90° (right angle) 90° (right angle) 90° (right angle)
Ports 1 × 1 1 × 1 1 × 1
Tab Up Up Up
Integrated magnetics Yes Yes Yes
Data rate 10/100BASE-TX All 10/100BASE-TX
PoE Not PoE rated Not PoE rated Not PoE rated
LED Yellow / Green No Yellow / Green
Mounting SMT DIP SMT
Shield tabs Yes Yes Yes
EMI gasket Yes Yes Yes
Operating temperature −40 to +85 °C −40 to +85 °C −40 to +85 °C
SYT211B083DB1A7CBS057Not sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

SYT211B083DB1A7CBS057 FAQ

Does SYT211B083DB1A7CBS057 have integrated magnetics?

Yes. SYT211B083DB1A7CBS057 integrates the Ethernet magnetics.

Check the datasheet for the rated data rate and whether the magnetics are PoE-rated before using it in a PoE design.

What does Tab Up mean for SYT211B083DB1A7CBS057?

Tab Up describes where the latch sits relative to the PCB.

With Tab Up the latch faces away from the board; with Tab Down it faces the board. Choose the orientation that matches your enclosure opening and LED placement, and check the mirrored pinout before swapping one for the other.

How do I get samples of SYT211B083DB1A7CBS057?

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Use the form below; the part number is filled in automatically.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

SYT211B083DB1A7CBS057

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohu.cn with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support