Quad-port 2.5G/5GBASE-T LAN transformer (Ethernet transformer): 96-pin DIP, 1500 Vrms isolation, PoE++(up to 1800mA). Operating temperature 0 to +70 °C.

Data rate
2.5G/5GBASE-T
Ports
Quad port
Mounting
DIP
Isolation voltage
1500 Vrms
PoE
PoE++(up to 1800mA)
Operating temperature
0 to +70 °C
WHDQ96504P2 LAN Transformer perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number WHDQ96504P2 is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 3865 5578
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

01Specifications

WHDQ96504P2 specifications

Key attributes

ParameterValue
Data rate 2.5G/5GBASE-T
Ports Quad port
Operating temperature 0 to +70 °C
PoE PoE++(up to 1800mA)
Mounting DIP
Pins 96
Pitch 2.0 mm

Electrical

ParameterValue
Isolation voltage 1500 Vrms

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

WHDQ96504P2Need samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where WHDQ96504P2 is used

  • Switches and routers
  • Wireless access points
  • IP cameras
  • Industrial control devices

Typical application

Ethernet PHYWHDQ96504P2RJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.

Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Connect the center taps according to your PHY type.Voltage-mode and current-mode PHYs need different center-tap biasing; a mismatch can break auto-negotiation.Check with your PHY →
  2. 02Terminate the line-side center taps with a Bob Smith network.It gives common-mode noise a defined path to chassis ground and helps EMC.
  3. 03Add line-side surge protection for outdoor or long-cable ports.Residual surge energy through the transformer can still damage the PHY.Troubleshooting guide →

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

WHDQ96504P2Not sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • WHDQ96504P2 Datasheet (PDF)2026-08-21 · This part Download ↓
  • 3D model (STEP)2026-05-08 · This part Download ↓
  • PCB Layout / Package2026-05-08 · This part Download ↓
  • LAN Transformer Reliability TestLatest · Product family View →
  • LAN Transformer EU RoHS ReportLatest · Product family View →
  • REACH SVHC test reportLatest · Communication electronic components View →
WHDQ96504P2Need another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Test report Test report · LAN transformers EU RoHSNo. WTH26H06190301C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-31
WTH26H06190301C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-31 LAN transformers View PDF →
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF →
Test report Test report · Product family Reliability test report
— — — Product family View PDF →

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples →

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter WHDQ96504P2This part WHDQ48201N0 WHSQ24015T0
Data rate 2.5G/5GBASE-T 2.5G/5GBASE-T 2.5G/5GBASE-T
Mounting DIP DIP SMD
Ports Quad port Dual port Single port
Pins 96 48 24
Pitch 2.0 mm 1.0 mm 1.0 mm
Operating temperature 0 to +70 °C −40 to +85 °C −40 to +85 °C
Isolation voltage 1500 Vrms 1500 Vrms 1500 Vrms
PoE PoE++(up to 1800mA) Not PoE rated Not PoE rated
WHDQ96504P2Not sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

FAQ LAN Transformer: WHDQ96504P2

On a four-port 90W PoE switch built around the WHDQ96504P2, can all four ports run at full load simultaneously?

Per-port capability is defined; simultaneous full load on all four has to be measured in the finished system. Each magnetic channel of the WHDQ96504P2 supports 900 mA and one port's full channels support 1800 mA. The stated PoE Support 90W is the power class at the PSE port output – the power finally available at the PD is reduced by cable loss and set by system classification and power management. Concurrency is a separate question: measure the actual component temperature at the highest planned internal temperature and worst airflow, then set the concurrency strategy.

Which pins belong to each of the four ports on the WHDQ96504P2?

Four contiguous blocks: Port 1 uses chip-side pins 1–12 and cable-side 85–96; Port 2 uses 13–24 and 73–84; Port 3 uses 25–36 and 61–72; Port 4 uses 37–48 and 49–60. Route each port's differential pairs and PoE returns along that partition, and keep port numbering aligned with the PHY channels and the front-panel RJ45 order, otherwise fault isolation during production test becomes difficult. The WHDQ96504P2 schematic is labelled by pin number, so build the netlist directly against pin numbers.

Can the pin protrusion figure for the WHDQ96504P2 be used directly as rear-side clearance?

No. The 2.60 mm on the drawing is the pin length from the underside of the body; how far the pin actually protrudes below the PCB depends on board thickness and insertion depth. Calculate rear-side component placement and enclosure stack-up against your own board stack rather than quoting 2.60 mm. Likewise, 14.50 mm is the maximum component body height of the WHDQ96504P2, and assembled board-side clearance must still allow for board thickness and process tolerance. Related multi-gig options are in the 2.5G/5G BASE-T range.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

WHDQ96504P2

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohu.cn with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support