DIN-Rail Three-Phase Multifunction Power Meter Reference Design
Illustrative design of a DIN-rail three-phase multifunction power meter for feeder metering in distribution cabinets, energy monitoring and power monitoring systems: direct three-phase four-wire voltage input, current input via external CTs, a three-phase metering IC for voltage, current, power and energy measurement, segment LCD, dual communication over RS-485 (Modbus RTU) and Ethernet (Modbus TCP), digital inputs, relay outputs and energy pulse outputs, and an AC/DC 85 ~ 265V auxiliary supply. This page covers the function, selection notes and available VOOHU parts for 31 component positions.
Illustrative PCB ⇄ Schematic
The illustrative layout shows placement and component positions; click any position to view selection notes, recommended parts and packages. The board is an illustration arranged by functional zone (not the actual layout), with the main board and the panel display drawn on one diagram; communication ports, I/O terminals, voltage / current terminals and the auxiliary supply terminal sit on the bottom edge, and the grid and external CTs are external nodes.
The three-phase voltages enter directly through terminal J4 and are scaled by resistor string RN1 into the metering IC voltage channels; the external CT secondary currents enter through terminal J5 into on-board power-frequency CTs CT1–CT3, whose secondaries are converted to voltage by burden resistors for the metering IC current channels. Metering IC U5 computes power and energy and connects to the MCU over SPI. Only phase A is drawn; phases B / C are identical. All parts in this chain are non-VOOHU positions: precision power-frequency metering CTs are not part of the VOOHU current transformer category (VOOHU current transformers are for high-frequency current sensing in switching power supplies); divider and burden resistor values per the metering IC datasheet.
Board bill of materials
Click any row to jump to that position and view its selection notes
| No. | Zone | Position | Ref. | VOOHU category | Recommended part | Availability |
|---|---|---|---|---|---|---|
| 01 | A RS-485 | RS-485 terminal | J1 | — | — | Non-VOOHU |
| 02 | A RS-485 | Gas discharge tube (stage 1) | G1 | GDT | WHGT090V1P0A | VOOHU |
| 03 | A RS-485 | Bus TVS (stage-2 clamp) | D1 | TVS / ESD | WHALD30E2B | VOOHU |
| 04 | A RS-485 | Bus differential-line common-mode choke | L1 | Signal Line CMC | WHAC-4532A-601ZP0 | VOOHU |
| 05 | A RS-485 | Isolated RS-485 transceiver | U1 | — | — | Non-VOOHU |
| 06 | B Ethernet | RJ45 port (with LEDs) | J2 | RJ45 Connectors | SYT561188AB1A1DB4 | VOOHU |
| 07 | B Ethernet | 10/100 LAN transformer | T1 | 10/100 LAN Transformers | WHSH16F01D4 | VOOHU |
| 08 | B Ethernet | Ethernet ESD array | D2 | TVS / ESD | WHALD03G4U | VOOHU |
| 09 | B Ethernet | 10/100 PHY (RMII) | U2 | Ethernet PHY | JL1101BR-NI | VOOHU |
| 10 | B Ethernet | PHY 25MHz crystal | Y1 | — | — | Non-VOOHU |
| 11 | C DI / DO · Pulse | I/O / pulse terminal (DI · DO · energy pulse) | J3 | — | — | Non-VOOHU |
| 12 | C DI / DO · Pulse | Digital input ESD | D3 | TVS / ESD | WHALD30E2B | VOOHU |
| 13 | C DI / DO · Pulse | Optocouplers (DI input · energy pulse output) | U3 U4 | — | — | Non-VOOHU |
| 14 | C DI / DO · Pulse | Relay output (DO) | K1 | — | — | Non-VOOHU |
| 15 | D Metering | Voltage input terminal (Ua / Ub / Uc / N) | J4 | — | — | Non-VOOHU |
| 16 | D Metering | Voltage-sensing divider resistor network | RN1 | — | — | Non-VOOHU |
| 17 | D Metering | Current input terminal (Ia / Ib / Ic in / out) | J5 | — | — | Non-VOOHU |
| 18 | D Metering | Power-frequency current-sensing CT ×3 | CT1 CT2 CT3 | — | — | Non-VOOHU |
| 19 | D Metering | Three-phase metering IC | U5 | — | — | Non-VOOHU |
| 20 | E Core · Display | MCU | U6 | — | — | Non-VOOHU |
| 21 | E Core · Display | Energy data storage (FRAM / EEPROM) | U7 | — | — | Non-VOOHU |
| 22 | E Core · Display | MCU crystal | Y2 | — | — | Non-VOOHU |
| 23 | E Core · Display | Segment LCD · key interface | J6 | — | — | Non-VOOHU |
| 24 | E Core · Display | MCU / metering supply filter molded inductor ×2 | L2 L3 | Molded Inductors | WHYTA0420 Series | VOOHU |
| 25 | F Power | Auxiliary supply terminal (AC/DC 85 ~ 265V) | J7 | — | — | Non-VOOHU |
| 26 | F Power | Input fuse · varistor | F1 RV1 | — | — | Non-VOOHU |
| 27 | F Power | Flyback auxiliary supply (isolated) | T2 U8 | — | — | Non-VOOHU |
| 28 | F Power | Synchronous buck (12V→3.3V) | U9 | — | — | Non-VOOHU |
| 29 | F Power | DC-DC molded inductor | L4 | Molded Inductors | WHYT0630 Series | VOOHU |
| 30 | F Power | Push-pull isolated power transformer | T3 | Push-Pull Transformers | WHST06K02A0 | VOOHU |
| 31 | F Power | Push-pull driver + isolated-side LDO | U10 U11 | — | — | Non-VOOHU |
Resources & downloads
Board bill of materials
Reference designators, zones, VOOHU categories, recommended parts and availability for all 31 positions. Opens directly in Excel.
Datasheet collection
Datasheet PDFs for the VOOHU parts recommended on this board.
Design files & footprint library
Schematic, PCB, and VOOHU part footprints and 3D models.
Coming soonRequest the full Smart Meter reference design packagefull package
Includes the BOM, datasheets for the recommended VOOHU parts and position-by-position selection notes. If you need advice for your communication interfaces, isolation requirements or installation environment, describe them in your request. We reply within 24 hours on working days.