Skip to main content
WHSH16F01D4 Single Port SMD 10/100 BASE-TX PIN16 LAN Transformer
Homepage   /   Products
LAN Transformer

WHSH16F01D4 10/100BASE-TX LAN Transformer

Single-port 10/100BASE-TX LAN transformer (Ethernet transformer): 16-pin SMD, 4800 Vrms isolation, not PoE rated. Operating temperature −40 to +85 °C.

Data rate
10/100BASE-TX
Ports
Single port
Mounting
SMD
Isolation voltage
4800 Vrms
PoE
Not PoE rated
Operating temperature
−40 to +85 °C
WHSH16F01D4 LAN Transformer perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number WHSH16F01D4 is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 3865 5578
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

01Specifications

WHSH16F01D4 specifications

Key attributes

ParameterValue
Data rate 10/100BASE-TX
Ports Single port
Operating temperature −40 to +85 °C
PoE Not PoE rated
Mounting SMD
Pins 16
Pitch 2.54 mm

Electrical

ParameterValue
Isolation voltage 4800 Vrms

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

WHSH16F01D4Need samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where WHSH16F01D4 is used

  • Switches and routers
  • Wireless access points
  • IP cameras
  • Industrial control devices

Typical application

Ethernet PHYWHSH16F01D4RJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.

Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Connect the center taps according to your PHY type.Voltage-mode and current-mode PHYs need different center-tap biasing; a mismatch can break auto-negotiation.Check with your PHY →
  2. 02Terminate the line-side center taps with a Bob Smith network.It gives common-mode noise a defined path to chassis ground and helps EMC.
  3. 03Add line-side surge protection for outdoor or long-cable ports.Residual surge energy through the transformer can still damage the PHY.Troubleshooting guide →

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

WHSH16F01D4Not sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • WHSH16F01D4 Datasheet (PDF)2025-09-16 · This part Download ↓
  • 3D model (STEP)2026-06-24 · This part Download ↓
  • PCB Layout / Package2025-12-29 · This part Download ↓
  • LAN Transformer Reliability TestLatest · Product family View →
  • LAN Transformer EU RoHS ReportLatest · Product family View →
  • REACH SVHC test reportLatest · Communication electronic components View →
WHSH16F01D4Need another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Test report Test report · LAN transformers EU RoHSNo. WTH26H06190301C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-31
WTH26H06190301C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-31 LAN transformers View PDF →
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF →
Test report Test report · Product family Reliability test report
— — — Product family View PDF →

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples →

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter WHSH16F01D4This part WHDH12401N0 WHSH16037D0
Data rate 10/100BASE-TX 10/100BASE-TX 10/100BASE-TX
Mounting SMD DIP SMD
Ports Single port Single port Single port
Pins 16 12 16
Pitch 2.54 mm 2.0 mm 1.27 mm
Operating temperature −40 to +85 °C 0 to +70 °C −40 to +85 °C
Isolation voltage 4800 Vrms 1500 Vrms 2500 Vrms
PoE Not PoE rated Not PoE rated Not PoE rated
WHSH16F01D4Not sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

FAQ LAN Transformer: WHSH16F01D4

What exactly does the 4800 VAC on the WHSH16F01D4 refer to?

The datasheet gives two alternative conditions: 4000 VAC held for 60 s, or 4800 VAC held for 1 s. The leakage criterion is 1 mA in both cases.

The site field quotes the higher number, but that figure belongs to the 1 s condition and cannot be compared directly against the standard 1500 VAC for 60 s. Match whichever the system's safety documentation states: a 60 s clause maps to the 4000 VAC figure, a 1 s clause to the 4800 VAC figure. The WHSH16F01D4 is the highest isolation grade in the 10/100 BASE-T range.

The WHSH16F01D4 says it is designed to IEC 60601-1 — does that mean it is medically certified?

No. The datasheet wording is a component-level design statement — designed to comply with IEC 60601-1 and IEC 60950-1, supplementary insulation at a working voltage of 250 Vrms — not an equipment-level certification.

Medical electrical equipment is certified as a whole; the transformer is one element in the insulation coordination, and what governs is the equipment's insulation diagram, its creepage and clearance allocation and its test reports. Where a medical project needs documentation, request the WHSH16F01D4 test and compliance files from VOOHU and have the equipment's safety engineer confirm the assumption holds.

Why are insertion and return loss looser on the WHSH16F01D4 than on standard parts?

Because the insulation distance is bought with physical separation, and that separation raises leakage inductance and coupling loss at the same time.

The datasheet states 7 mm clearance and 10 mm creepage; insertion loss is correspondingly -3.0 dB Max from 1–100 MHz and return loss starts at -10 dB across four bands, against -1.1 dB and -18 dB on the standard parts. This is the cost of the insulation grade, not a defect — the WHSH16F01D4 suits designs where insulation outranks link margin. A design already tight on link budget has to recompute with these figures. Standard-loss options are in the 10/100 BASE-T range.

Can the WHSH16F01D4 replace an existing 16-pin surface-mount part on the board?

No — both are 16-pin surface-mount, but the packages are not comparable.

The WHSH16F01D4 body measures 24.15 × 15.50 mm against 12.80 × 6.90 mm on the standard parts, and its terminal pitch is 2.54 mm rather than 1.27 mm. Board area is therefore roughly four times larger and the pitch is doubled, so the land pattern has to be redrawn. Choosing it is a layout-stage decision, not something a later substitution can absorb, and the 12.80 mm height has to be checked against the enclosure. Standard-size options are in the 10/100 BASE-T range.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

WHSH16F01D4

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohu.cn with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support