WHSG24002TG Single Port SMD Gigabit Base-T PIN24 non-PoE LAN Transformer
Homepage   /   Products
LAN Transformer

WHSG24002TG Gigabit LAN Transformer

Single-port 10/100/1000BASE-T LAN transformer (Ethernet transformer): 24-pin SMD, 1500 Vrms isolation, not PoE rated. Operating temperature −40 to +85 °C.

Data rate
10/100/1000BASE-T
Ports
Single port
Mounting
SMD
Isolation voltage
1500 Vrms
PoE
Not PoE rated
Operating temperature
−40 to +85 °C
WHSG24002TG LAN Transformer perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number WHSG24002TG is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Leave a phone number or an email. Either one is enough.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 5804 1040
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

Urgent? Message us on WhatsApp: +86 133 5804 1040

01Specifications

WHSG24002TG specifications

Key attributes

ParameterValue
Data rate 10/100/1000BASE-T
Ports Single port
Operating temperature −40 to +85 °C
PoE Not PoE rated
Mounting SMD
Pins 24
Pitch 1.0 mm

Electrical

ParameterValue
Isolation voltage 1500 Vrms

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

WHSG24002TGNeed samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where WHSG24002TG is used

  • Switches and routers
  • Wireless access points
  • IP cameras
  • Industrial control devices

Typical application

Ethernet PHYWHSG24002TGRJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.

Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Connect the center taps according to your PHY type.Voltage-mode and current-mode PHYs need different center-tap biasing; a mismatch can break auto-negotiation.Check with your PHY
  2. 02Terminate the line-side center taps with a Bob Smith network.It gives common-mode noise a defined path to chassis ground and helps EMC.
  3. 03Add line-side surge protection for outdoor or long-cable ports.Residual surge energy through the transformer can still damage the PHY.Troubleshooting guide

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

WHSG24002TGNot sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • WHSG24002TG Datasheet (PDF)2024-11-25 · This part Download
  • 3D model (STEP)2026-06-05 · This part Download
  • PCB Layout / Package2025-12-29 · This part Download
  • LAN Transformer Reliability TestLatest · Product family View
  • LAN Transformer EU RoHS ReportLatest · Product family View
  • REACH SVHC test reportLatest · Communication electronic components View
WHSG24002TGNeed another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF Verify Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF Verify Scope: R&D and sales of precision electronic connectors
Test report Test report · LAN transformers EU RoHSNo. WTH26H06190301C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-31
WTH26H06190301C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-31 LAN transformers View PDF
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF
Test report Test report · Product family Reliability test report
— — — Product family View PDF

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter WHSG24002TGThis part WHSG24002G WHSG24015G
Data rate 10/100/1000BASE-T 10/100/1000BASE-T 10/100/1000BASE-T
Mounting SMD SMD SMD
Ports Single port Single port Single port
Pins 24 24 24
Pitch 1.0 mm 1.0 mm 1.0 mm
Operating temperature −40 to +85 °C 0 to +70 °C 0 to +70 °C
Isolation voltage 1500 Vrms 1500 Vrms 1500 Vrms
PoE Not PoE rated Not PoE rated Not PoE rated
WHSG24002TGNot sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

FAQ LAN Transformer: WHSG24002TG

What equipment is the WHSG24002TG suited to?

The WHSG24002TG suits industrial Gigabit ports where the component temperature may fall anywhere between -40 °C and +85 °C. Typical uses are DIN-rail industrial switches, Gigabit access ports inside outdoor enclosures, shop-floor gateways and wide-temperature edge equipment. The WHSG24002TG is a single-port, non-PoE 100/1000 BASE-T transformer, so the port has to be powered locally.

The lower figure is the operating limit of the component, not a demonstrated cold-start capability for the finished product – low-temperature power-up still has to be measured with the target PHY and cable. Other options are listed in the 100/1000 BASE-T range.

Can the centre taps of the WHSG24002TG carry current?

No. The datasheet assigns no DC balance current capability to the centre taps of the WHSG24002TG, so they cannot be used as a supply path. There is no current item among its electrical entries. Terminate the centre taps according to the reference design for the target PHY.

The 8 mA DC bias on the OCL line is a direct current superimposed during the inductance measurement, not a permitted operating current, and the two cannot be converted into one another. Where a wide-temperature port also has to deliver power, send VOOHU the target wattage, current and temperature range and we will reselect from the 100/1000 BASE-T range.

How do I choose between the WHSG24002TG and the WHSG24002G?

Decide on operating temperature: take the WHSG24002TG for -40 °C to +85 °C, or the WHSG24002G where 0 °C to +70 °C is enough. The two are identical value for value on mechanical dimensions, suggested land pattern, pin-to-net assignment and every electrical figure, so switching between them does not change the electrical design.

There is one small difference in how the documents are written: the datasheet of the WHSG24002TG carries an extra RoHS compliance line that the other does not print. That is a documentation difference rather than a selection criterion; ask VOOHU for the compliance paperwork when a formal declaration is needed. Both parts sit in the 100/1000 BASE-T range.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

WHSG24002TG

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohuele.com with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support