Skip to main content
WHSG24015G Single Port SMD Gigabit Base-T PIN24 NON-PoE LAN Transformer
Homepage   /   Products
LAN Transformer

WHSG24015G Gigabit LAN Transformer

Single-port 10/100/1000BASE-T LAN transformer (Ethernet transformer): 24-pin SMD, 1500 Vrms isolation, not PoE rated. Operating temperature 0 to +70 °C.

Data rate
10/100/1000BASE-T
Ports
Single port
Mounting
SMD
Isolation voltage
1500 Vrms
PoE
Not PoE rated
Operating temperature
0 to +70 °C
WHSG24015G LAN Transformer perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number WHSG24015G is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 3865 5578
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

01Specifications

WHSG24015G specifications

Key attributes

ParameterValue
Data rate 10/100/1000BASE-T
Ports Single port
Operating temperature 0 to +70 °C
PoE Not PoE rated
Mounting SMD
Pins 24
Pitch 1.0 mm

Electrical

ParameterValue
Isolation voltage 1500 Vrms

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

WHSG24015GNeed samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where WHSG24015G is used

  • Switches and routers
  • Wireless access points
  • IP cameras
  • Industrial control devices

Typical application

Ethernet PHYWHSG24015GRJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.

Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Connect the center taps according to your PHY type.Voltage-mode and current-mode PHYs need different center-tap biasing; a mismatch can break auto-negotiation.Check with your PHY →
  2. 02Terminate the line-side center taps with a Bob Smith network.It gives common-mode noise a defined path to chassis ground and helps EMC.
  3. 03Add line-side surge protection for outdoor or long-cable ports.Residual surge energy through the transformer can still damage the PHY.Troubleshooting guide →

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

WHSG24015GNot sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • WHSG24015G Datasheet (PDF)2024-11-25 · This part Download ↓
  • 3D model (STEP)2026-06-05 · This part Download ↓
  • PCB Layout / Package2025-12-29 · This part Download ↓
  • LAN Transformer Reliability TestLatest · Product family View →
  • LAN Transformer EU RoHS ReportLatest · Product family View →
  • REACH SVHC test reportLatest · Communication electronic components View →
WHSG24015GNeed another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Test report Test report · LAN transformers EU RoHSNo. WTH26H06190301C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-31
WTH26H06190301C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-31 LAN transformers View PDF →
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF →
Test report Test report · Product family Reliability test report
— — — Product family View PDF →

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples →

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter WHSG24015GThis part WHSG24002TG WHSG24002G
Data rate 10/100/1000BASE-T 10/100/1000BASE-T 10/100/1000BASE-T
Mounting SMD SMD SMD
Ports Single port Single port Single port
Pins 24 24 24
Pitch 1.0 mm 1.0 mm 1.0 mm
Operating temperature 0 to +70 °C −40 to +85 °C 0 to +70 °C
Isolation voltage 1500 Vrms 1500 Vrms 1500 Vrms
PoE Not PoE rated Not PoE rated Not PoE rated
WHSG24015GNot sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

FAQ LAN Transformer: WHSG24015G

How tall is the WHSG24015G?

The WHSG24015G body is 4.00 mm ±0.50 mm high, among the lowest-profile Gigabit transformers in this catalogue.

The WHSG24R05N0 on the same land pattern stands 8.25 mm ±0.50 mm — both share a 15.10 × 7.10 mm plan, 1.00 mm pitch and 11.00 mm span, so the pads carry over and height is the one thing that differs, by a factor of two. Where internal clearance is tight, or an air duct has to pass above the transformer, this belongs in the first round of selection.

Does the WHSG24015G support PoE?

The datasheet carries no PoE current item, so the WHSG24015G should not be selected as a PoE part and its port has to be powered locally.

The centre taps serve as AC termination and common-mode reference only. Where power over the cable is needed, move at selection time to a part that states a current capability — preferably one that also names the scope, since several parts in the 100/1000 BASE-T range print both the per-channel and the full-channel figures.

Which pins of the WHSG24015G face the PHY and which face the cable?

Pins 1–12 are the chip side, named TCT and TD1±–TD4±; pins 13–24 are the cable side, named MCT1–MCT4 and MX1±–MX4±.

Inside, the WHSG24015G holds four 1CT:1CT units — the four channels, or two pairsets, of one Gigabit port. Orient pins 1–12 toward the PHY and 13–24 toward the RJ45 and all four pairs run straight through. Centre-tap prefixes follow several conventions across the 100/1000 BASE-T range, so take them from this part's own drawing.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

WHSG24015G

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohu.cn with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support