Dual-port 10/100/1000BASE-T LAN transformer (Ethernet transformer): 48-pin SMD, 1500 Vrms isolation, not PoE rated. Operating temperature −40 to +85 °C.

Data rate
10/100/1000BASE-T
Ports
Dual port
Mounting
SMD
Isolation voltage
1500 Vrms
PoE
Not PoE rated
Operating temperature
−40 to +85 °C
WHSG48001TG LAN Transformer perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number WHSG48001TG is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 3865 5578
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

01Specifications

WHSG48001TG specifications

Key attributes

ParameterValue
Data rate 10/100/1000BASE-T
Ports Dual port
Operating temperature −40 to +85 °C
PoE Not PoE rated
Mounting SMD
Pins 48
Pitch 1.02 mm

Electrical

ParameterValue
Isolation voltage 1500 Vrms

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

WHSG48001TGNeed samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where WHSG48001TG is used

  • Switches and routers
  • Wireless access points
  • IP cameras
  • Industrial control devices

Typical application

Ethernet PHYWHSG48001TGRJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.

Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Connect the center taps according to your PHY type.Voltage-mode and current-mode PHYs need different center-tap biasing; a mismatch can break auto-negotiation.Check with your PHY →
  2. 02Terminate the line-side center taps with a Bob Smith network.It gives common-mode noise a defined path to chassis ground and helps EMC.
  3. 03Add line-side surge protection for outdoor or long-cable ports.Residual surge energy through the transformer can still damage the PHY.Troubleshooting guide →

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

WHSG48001TGNot sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • WHSG48001TG Datasheet (PDF)2025-05-27 · This part Download ↓
  • 3D model (STEP)2026-06-23 · This part Download ↓
  • PCB Layout / Package2025-12-29 · This part Download ↓
  • LAN Transformer Reliability TestLatest · Product family View →
  • LAN Transformer EU RoHS ReportLatest · Product family View →
  • REACH SVHC test reportLatest · Communication electronic components View →
WHSG48001TGNeed another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Test report Test report · LAN transformers EU RoHSNo. WTH26H06190301C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-31
WTH26H06190301C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-31 LAN transformers View PDF →
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF →
Test report Test report · Product family Reliability test report
— — — Product family View PDF →

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples →

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter WHSG48001TGThis part WHSG48001G WHSG48002G
Data rate 10/100/1000BASE-T 10/100/1000BASE-T 10/100/1000BASE-T
Mounting SMD SMD SMD
Ports Dual port Dual port Dual port
Pins 48 48 48
Pitch 1.02 mm 1.02 mm 1.02 mm
Operating temperature −40 to +85 °C 0 to +70 °C 0 to +70 °C
Isolation voltage 1500 Vrms 1500 Vrms 1500 Vrms
PoE Not PoE rated Not PoE rated Not PoE rated
WHSG48001TGNot sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

FAQ LAN Transformer: WHSG48001TG

Can the WHSG48001TG drop in for the WHSG48001G?

Yes, and it is a complete drop-in: body, the net names of all 48 pins, land pattern, internal element order and every electrical rating match, with only two temperature fields different. The WHSG48001TG is rated -40 °C to +85 °C operating and -40 °C to +125 °C storage; the WHSG48001G is 0 °C to +70 °C and -40 °C to +85 °C.

Neither the PCB nor the termination network changes; only the cold start-up verification has to be repeated at the wider grade.

When is the WHSG48001TG required instead of the standard-temperature grade?

Where the transformer's own location powers up below 0 °C, or runs above +70 °C for long stretches.

The deciding number is the temperature at the part's location, not the cabinet or room ambient — a surface-mount part sits on the board surface, and near the power supply or downstream in the airflow it runs well above the inlet temperature. The WHSG48001TG is rated -40 °C to +85 °C, leaving headroom at both ends against the standard grades in the 100/1000 BASE-T range.

Are the two ports of the WHSG48001TG independent of each other?

Yes. The WHSG48001TG holds eight separate 1CT:1CT units, four channels to each Gigabit port.

One channel is one differential pair; two channels, one out and one back, make a pairset, so each Gigabit port is two pairsets. Cross talk between the ports is held to -30 dB Min across 1–100 MHz, and each port keeps its own termination and grounding as the PHY reference design specifies. Other port counts sit in the 100/1000 BASE-T range.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

WHSG48001TG

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohu.cn with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support