Skip to main content
WHSM24301G Single Port SMD(Low height) 10G PIN24 non-PoE LAN Transformer
Homepage   /   Products
LAN Transformer

WHSM24301G 10GBASE-T LAN Transformer

Single-port 10GBASE-T LAN transformer (Ethernet transformer): 24-pin SMD (low profile), 1500 Vrms isolation, not PoE rated. Operating temperature 0 to +70 °C.

Data rate
10GBASE-T
Ports
Single port
Mounting
SMD (low profile)
Isolation voltage
1500 Vrms
PoE
Not PoE rated
Operating temperature
0 to +70 °C
WHSM24301G LAN Transformer perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number WHSM24301G is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 3865 5578
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

01Specifications

WHSM24301G specifications

Key attributes

ParameterValue
Data rate 10GBASE-T
Ports Single port
Operating temperature 0 to +70 °C
PoE Not PoE rated
Mounting SMD (low profile)
Pins 24
Pitch 1.27 mm

Electrical

ParameterValue
Isolation voltage 1500 Vrms

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

WHSM24301GNeed samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where WHSM24301G is used

  • Switches and routers
  • Wireless access points
  • IP cameras
  • Industrial control devices

Typical application

Ethernet PHYWHSM24301GRJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.

Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Connect the center taps according to your PHY type.Voltage-mode and current-mode PHYs need different center-tap biasing; a mismatch can break auto-negotiation.Check with your PHY →
  2. 02Terminate the line-side center taps with a Bob Smith network.It gives common-mode noise a defined path to chassis ground and helps EMC.
  3. 03Add line-side surge protection for outdoor or long-cable ports.Residual surge energy through the transformer can still damage the PHY.Troubleshooting guide →

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

WHSM24301GNot sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • WHSM24301G Datasheet (PDF)2024-11-25 · This part Download ↓
  • 3D model (STEP)2026-06-24 · This part Download ↓
  • PCB Layout / Package2025-12-29 · This part Download ↓
  • LAN Transformer Reliability TestLatest · Product family View →
  • LAN Transformer EU RoHS ReportLatest · Product family View →
  • REACH SVHC test reportLatest · Communication electronic components View →
WHSM24301GNeed another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Test report Test report · LAN transformers EU RoHSNo. WTH26H06190301C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-31
WTH26H06190301C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-31 LAN transformers View PDF →
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF →
Test report Test report · Product family Reliability test report
— — — Product family View PDF →

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples →

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter WHSM24301GThis part WHSM24P01G WHSM24P02-1PG
Data rate 10GBASE-T 10GBASE-T 10GBASE-T
Mounting SMD (low profile) SMD SMD
Ports Single port Single port Single port
Pins 24 24 24
Pitch 1.27 mm 1.0 mm 1.0 mm
Operating temperature 0 to +70 °C 0 to +70 °C 0 to +70 °C
Isolation voltage 1500 Vrms 1500 Vrms 1500 Vrms
PoE Not PoE rated Not PoE rated PoE+ (up to 720 mA)
WHSM24301GNot sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

FAQ LAN Transformer: WHSM24301G

What equipment is the WHSM24301G suitable for?

The WHSM24301G suits indoor 10G data ports where the component temperature stays between 0 °C and +70 °C. Typical uses are switch uplinks, server NICs, NAS units and workstation ports. The WHSM24301G is a single-port, non-PoE 10G BASE-T transformer, so the port has to be powered locally.

If the equipment must power up below 0 °C or work outdoors long term, move to a wide-temperature version. Other options are listed in the 10G BASE-T range.

Can the centre taps of the WHSM24301G carry current?

No. The datasheet assigns no DC balance current capability to the centre taps of the WHSM24301G, so they cannot be used as a supply path. Terminate them according to the reference design for the target PHY. If the port has to deliver power, move to a part in this range that carries a stated PoE current.

How do I choose between the WHSM24301G and the WHSM24P01G?

The WHSM24301G and WHSM24P01G are electrically equivalent, so the choice comes down to package and stocking rather than performance. Both are single-port, non-PoE 10G BASE-T transformers operating from 0 °C to +70 °C, and both quote crosstalk and common-mode rejection as -25 dB typ.

Where they differ is stocking and storage: the WHSM24301G ships 1500 pcs per reel and is stored from -40 °C to +85 °C; the WHSM24P01G ships 450 pcs per reel and is stored from -20 °C to +125 °C. They are different packages, so check outline and land pattern against each drawing before substituting one for the other.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

WHSM24301G

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohu.cn with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support