Samples
Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.
Get a Quote or Samples →Single-port 10/100/1000BASE-T LAN transformer (Ethernet transformer): 24-pin DIP, 1500 Vrms isolation, not PoE rated. Operating temperature 0 to +70 °C.
Buy Online
When you click Get a Quote or Samples or Add to Inquiry, part number WHDG24102G is filled in automatically.
Leave your details and we will send a tailored volume quote.
Our sales team will contact you within 1 business day.
Reach our sales team for pricing and lead time.

We have received your request. Our sales team will contact you within 1 business day.
01Specifications
Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.
02Applications
The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.
Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).
Typical application for reference. Follow the PHY vendor's reference design.
Reference designs by application:Industrial ControlSecurity MonitoringData Communication
03Documents
04Quality
ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.
05Ordering
Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.
Get a Quote or Samples →06Compare
Red marks values that differ from this part; data from the published parameters of each part.
07FAQ
Gigabit, single port.
The WHDG24102G holds four 1CT:1CT units forming four channels across two pairsets — two pairsets per port is the Gigabit-and-above structure, where a 100M port has only two channels in one pairset. The drawing title reads 100/1000 BASE-TX. Counting transformer units is the most direct check: four units in a single-port part means Gigabit, two means 100M. Other single-port parts are listed in the 100/1000 BASE-T range.
No. The WHDG24102G electrical block runs to eleven items and none states a current capability or an IEEE power class.
The 8 mA in the datasheet is the DC bias applied while measuring open-circuit inductance to verify magnetising behaviour — it is not current available to a load. Whether a part can deliver power is decided by a separate line stating current capability and the applicable IEEE class, not by the test condition on the inductance line. PoE parts are listed in the 100/1000 BASE-T range.
0 °C to +70 °C, a commercial grade; storage is quoted separately as -40 °C to +85 °C.
The two have to be read separately — the storage range is the unpowered limit and must not be used as an operating range, and reading its -40 °C as an available cold end is a common mistake. Where equipment will power up below 0 °C, choose a part whose operating range reaches -40 °C. Isolation on the WHDG24102G is 1500 VAC / 1 mA / 60 s. Wide-temperature options are listed in the 100/1000 BASE-T range.
08Support
REQUEST TYPE
An engineer will contact you within 1 business day using the details you provided.
Typical application