Skip to main content
WHDG96502PTG Quad Ports DIP Gigabit Base-T PIN96 PoE:720 mA LAN Transformer
Homepage   /   Products
LAN Transformer

WHDG96502PTG Gigabit PoE+ LAN Transformer

Quad-port 10/100/1000BASE-T LAN transformer (Ethernet transformer): 96-pin DIP, 1500 Vrms isolation, PoE+ (up to 720 mA). Operating temperature −40 to +85 °C.

Data rate
10/100/1000BASE-T
Ports
Quad port
Mounting
DIP
Isolation voltage
1500 Vrms
PoE
PoE+ (up to 720 mA)
Operating temperature
−40 to +85 °C
WHDG96502PTG LAN Transformer perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number WHDG96502PTG is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 3865 5578
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

01Specifications

WHDG96502PTG specifications

Key attributes

ParameterValue
Data rate 10/100/1000BASE-T
Ports Quad port
Operating temperature −40 to +85 °C
PoE PoE+ (up to 720 mA)
Mounting DIP
Pins 96
Pitch 2.0 mm

Electrical

ParameterValue
Isolation voltage 1500 Vrms

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

WHDG96502PTGNeed samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where WHDG96502PTG is used

  • Switches and routers
  • Wireless access points
  • IP cameras
  • Industrial control devices

Typical application

Ethernet PHYWHDG96502PTGRJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.

Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Connect the center taps according to your PHY type.Voltage-mode and current-mode PHYs need different center-tap biasing; a mismatch can break auto-negotiation.Check with your PHY →
  2. 02Terminate the line-side center taps with a Bob Smith network.It gives common-mode noise a defined path to chassis ground and helps EMC.
  3. 03Add line-side surge protection for outdoor or long-cable ports.Residual surge energy through the transformer can still damage the PHY.Troubleshooting guide →

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

WHDG96502PTGNot sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • WHDG96502PTG Datasheet (PDF)2026-01-06 · This part Download ↓
  • 3D model (STEP)2026-06-05 · This part Download ↓
  • PCB Layout / Package2025-12-29 · This part Download ↓
  • LAN Transformer Reliability TestLatest · Product family View →
  • LAN Transformer EU RoHS ReportLatest · Product family View →
  • REACH SVHC test reportLatest · Communication electronic components View →
WHDG96502PTGNeed another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Test report Test report · LAN transformers EU RoHSNo. WTH26H06190301C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-31
WTH26H06190301C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-31 LAN transformers View PDF →
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF →
Test report Test report · Product family Reliability test report
— — — Product family View PDF →

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples →

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter WHDG96502PTGThis part WHDG96502G WHDG96503G
Data rate 10/100/1000BASE-T 10/100/1000BASE-T 10/100/1000BASE-T
Mounting DIP DIP DIP
Ports Quad port Quad port Quad port
Pins 96 96 96
Pitch 2.0 mm 2.0 mm 2.0 mm
Operating temperature −40 to +85 °C 0 to +70 °C 0 to +70 °C
Isolation voltage 1500 Vrms 1500 Vrms 1500 Vrms
PoE PoE+ (up to 720 mA) Not PoE rated PoE (up to 350 mA)
WHDG96502PTGNot sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

FAQ LAN Transformer: WHDG96502PTG

Why is the open-circuit inductance of the WHDG96502PTG specified at 21 mA DC bias?

Because open-circuit inductance is measured under a DC bias, and the figure only means something if the bias is close to the real supply operating point.

The WHDG96502PTG states 350 µH Min at 21 mA bias, while the non-PoE parts in the same family state the same figure at 8 mA. When comparing PoE parts, read the bias condition alongside the inductance — comparing the numbers alone compares two different operating conditions. Bias conditions vary across the 100/1000 BASE-T range.

What is the difference between the WHDG96502PTG and the WHDG96504PTG?

Published electrical ratings, package dimensions, pin numbering and PoE rating all match; the difference is on the schematic — the common-mode choke on each channel is drawn with three windings on the WHDG96502PTG and two on the WHDG96504PTG.

Both assign pins 1–48 to the chip side. Where the design has specific requirements on the common-mode path, tell us the target PHY and EMC approach rather than picking from the parameter table alone.

Which side of the WHDG96502PTG faces the PHY?

Pins 1–48 are the chip side and pins 49–96 the cable side, labelled group by group on the drawing; the common-mode choke sits on the chip side and the transformer on the cable side.

One thing to watch: the WHDG96503PTG shares the package and the pin numbering of the WHDG96502PTG but its drawing labels the two sides the other way round. The parts cannot be placed in the same orientation, and any change between them needs the orientation re-checked against each drawing.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

WHDG96502PTG

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohu.cn with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support