Skip to main content
WHS16037-2KG Single Port SMD 10/100Base-TX PIN16 non-PoE LAN Transformer
Homepage   /   Products
LAN Transformer

WHS16037-2KG 10/100BASE-TX LAN Transformer

Single-port 10/100BASE-TX LAN transformer (Ethernet transformer): 16-pin SMD, 2500 Vrms isolation, not PoE rated. Operating temperature 0 to +70 °C.

Data rate
10/100BASE-TX
Ports
Single port
Mounting
SMD
Isolation voltage
2500 Vrms
PoE
Not PoE rated
Operating temperature
0 to +70 °C
WHS16037-2KG LAN Transformer perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number WHS16037-2KG is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Leave a phone number or an email. Either one is enough.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 5804 1040
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

Urgent? Message us on WhatsApp: +86 133 5804 1040

01Specifications

WHS16037-2KG specifications

Key attributes

ParameterValue
Data rate 10/100BASE-TX
Ports Single port
Operating temperature 0 to +70 °C
PoE Not PoE rated
Mounting SMD
Pins 16
Pitch 1.27 mm

Electrical

ParameterValue
Isolation voltage 2500 Vrms

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

WHS16037-2KGNeed samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where WHS16037-2KG is used

  • Switches and routers
  • Wireless access points
  • IP cameras
  • Industrial control devices

Typical application

Ethernet PHYWHS16037-2KGRJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.

Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Connect the center taps according to your PHY type.Voltage-mode and current-mode PHYs need different center-tap biasing; a mismatch can break auto-negotiation.Check with your PHY
  2. 02Terminate the line-side center taps with a Bob Smith network.It gives common-mode noise a defined path to chassis ground and helps EMC.
  3. 03Add line-side surge protection for outdoor or long-cable ports.Residual surge energy through the transformer can still damage the PHY.Troubleshooting guide

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

WHS16037-2KGNot sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • WHS16037-2KG Datasheet (PDF)2024-11-25 · This part Download
  • 3D model (STEP)2025-10-29 · This part Download
  • PCB Layout / Package2025-12-29 · This part Download
  • LAN Transformer Reliability TestLatest · Product family View
  • LAN Transformer EU RoHS ReportLatest · Product family View
  • REACH SVHC test reportLatest · Communication electronic components View
WHS16037-2KGNeed another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF Verify Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF Verify Scope: R&D and sales of precision electronic connectors
Test report Test report · LAN transformers EU RoHSNo. WTH26H06190301C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-31
WTH26H06190301C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-31 LAN transformers View PDF
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF
Test report Test report · Product family Reliability test report
— — — Product family View PDF

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter WHS16037-2KGThis part WHS16037TG WHS160B1PTG
Data rate 10/100BASE-TX 10/100BASE-TX 10/100BASE-TX
Mounting SMD SMD SMD
Ports Single port Single port Single port
Pins 16 16 16
Pitch 1.27 mm 1.27 mm 1.27 mm
Operating temperature 0 to +70 °C −40 to +85 °C −40 to +85 °C
Isolation voltage 2500 Vrms 1500 Vrms 1500 Vrms
PoE Not PoE rated Not PoE rated PoE+ (up to 850 mA)
WHS16037-2KGNot sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

FAQ LAN Transformer: WHS16037-2KG

What does the `-2K` in the WHS16037-2KG part number mean?

The suffix marks the isolation grade: the WHS16037-2KG is rated 2500 VAC where the standard parts on its land pattern are rated 1500 VAC.

The test conditions differ as well: 1 mA for 2 s here against 1 mA for 60 s there. Everything else — inductance, DC resistance, turns ratio, insertion and return loss, cross talk, common-mode rejection, outline and land pattern — matches the standard part. Where the safety documentation calls for the higher short-duration figure, this part fits without a board change.

Which is more demanding, 2500 VAC for 2 s or 1500 VAC for 60 s?

Neither is simply stricter — the two are different test conditions and cannot be compared on voltage alone.

The WHS16037-2KG is tested at 2500 VAC for 2 s, the standard parts at 1500 VAC for 60 s — 1000 V higher, but applied for a thirtieth of the time. Which one to choose follows from how the system's safety documentation is written: a short-duration high-voltage clause points to the WHS16037-2KG, a longer mid-voltage clause to the standard part. Above 1500 VAC the product line also lists 2500, 3000, 4000, 4800 and 5000 VAC grades, each with its own dwell time.

How is the WHS16037-2KG supplied?

On ø330 mm tape and reel, 600 pieces per reel, three reels to an inner carton for 1800 pieces and two inner cartons to an export carton for 3600.

The WHS16037-2KG is surface-mount and reflow-assembled, with coplanarity held to 0.10 mm across 16 terminations. The standard part and the wide-temperature part on the same land pattern ship the same quantities, so reel count cannot be used to tell the three apart — incoming checks have to go by the marking on the body.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

WHS16037-2KG

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohuele.com with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support