Skip to main content
WHS16002GM Single Port SMD 10/100Base-TX PIN16 non-PoE LAN Transformer
Homepage   /   Products
LAN Transformer

WHS16002GM 10/100BASE-TX LAN Transformer

Single-port 10/100BASE-TX LAN transformer (Ethernet transformer): 16-pin SMD, 1500 Vrms isolation, not PoE rated. Operating temperature −55 to +150 °C.

Data rate
10/100BASE-TX
Ports
Single port
Mounting
SMD
Isolation voltage
1500 Vrms
PoE
Not PoE rated
Operating temperature
−55 to +150 °C
WHS16002GM LAN Transformer perspective view

When you click Get a Quote or Samples or Add to Inquiry, part number WHS16002GM is filled in automatically.

Request a Quote

Leave your details and we will send a tailored volume quote.

Our sales team will contact you within 1 business day.

Contact Sales

Reach our sales team for pricing and lead time.

Contact Sales
Sales Hotline: +86 133 3865 5578
Email: voohu@voohuele.com
✓

Submitted

We have received your request. Our sales team will contact you within 1 business day.

01Specifications

WHS16002GM specifications

Key attributes

ParameterValue
Data rate 10/100BASE-TX
Ports Single port
Operating temperature −55 to +150 °C
PoE Not PoE rated
Mounting SMD
Pins 16
Pitch 1.27 mm

Electrical

ParameterValue
Isolation voltage 1500 Vrms

Values from published data for this part (parameters, FAQ and evaluation report). The datasheet prevails.

WHS16002GMNeed samples, or a value that is not in this table? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

02Applications

Where WHS16002GM is used

  • Switches and routers
  • Wireless access points
  • IP cameras
  • Industrial control devices

Typical application

Ethernet PHYWHS16002GMRJ45 jackTD+1 TX+TD−2 TX−RD+3 RX+RD−6 RX−ESD / TVS (optional)TX · 1CT:1CTRX · 1CT:1CTCTCTPHY-side CT: bias per PHY typeR1 75 ΩR2 75 ΩC1 1000 pF / 2 kVBob Smith terminationShield to chassis

The transformer isolates the PHY from the cable and couples the TX and RX differential pairs to the RJ45 jack.

Center-tap biasing on the PHY side depends on the PHY type (voltage-mode or current-mode).

Typical application for reference. Follow the PHY vendor's reference design.

Design notes

  1. 01Connect the center taps according to your PHY type.Voltage-mode and current-mode PHYs need different center-tap biasing; a mismatch can break auto-negotiation.Check with your PHY →
  2. 02Terminate the line-side center taps with a Bob Smith network.It gives common-mode noise a defined path to chassis ground and helps EMC.
  3. 03Add line-side surge protection for outdoor or long-cable ports.Residual surge energy through the transformer can still damage the PHY.Troubleshooting guide →

Reference designs by application:Industrial ControlSecurity MonitoringData Communication

WHS16002GMNot sure it fits your PHY and layout? An engineer can check your design. Get a Quote or Samples + Add to Inquiry
  • WHS16002GM Datasheet (PDF)2024-11-25 · This part Download ↓
  • 3D model (STEP)2025-10-29 · This part Download ↓
  • PCB Layout / Package2025-12-29 · This part Download ↓
  • LAN Transformer Reliability TestLatest · Product family View →
  • LAN Transformer EU RoHS ReportLatest · Product family View →
  • REACH SVHC test reportLatest · Communication electronic components View →
WHS16002GMNeed another file format, or samples to test? Ask our FAE team. Get a Quote or Samples + Add to Inquiry

04Quality

Quality and compliance

DocumentNo.Issued / tested byDateApplies toActions
Certificate Certificate · Company ISO 9001:2015No. 19826Q02503R101 Quality management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826Q02503R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Certificate Certificate · Company ISO 14001:2015No. 19826E01323R101 Environmental management systemBeijing Xinjiyuan Certification Co., Ltd.Valid 2026-10-17 to 2029-10-16
19826E01323R101 Beijing Xinjiyuan Certification Co., Ltd. Valid2026-10-17 to 2029-10-16 Company View PDF → Verify → Scope: R&D and sales of precision electronic connectors
Test report Test report · LAN transformers EU RoHSNo. WTH26H06190301C 2011/65/EU and (EU) 2015/863, 10 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-31
WTH26H06190301C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-31 LAN transformers View PDF →
Test report Test report · Communication electronic components REACH SVHCNo. WTH26H06167853C 253 substancesWaltek Testing Group HCT (Shenzhen) Co., Ltd.Issued 2026-07-01
WTH26H06167853C Waltek Testing Group HCT (Shenzhen) Co., Ltd. Issued2026-07-01 Communication electronic components View PDF →
Test report Test report · Product family Reliability test report
— — — Product family View PDF →

ISO certificates cover VOOHU's management systems. RoHS and REACH test reports cover tested samples of each product family.

05Ordering

Ordering and delivery

05.1

Samples

Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project.

Get a Quote or Samples →

06Compare

Same-series Comparison

Red marks values that differ from this part; data from the published parameters of each part.

Parameter WHS16002GMThis part WHS160B1PTG WHS16002-1PTG
Data rate 10/100BASE-TX 10/100BASE-TX 10/100BASE-TX
Mounting SMD SMD SMD
Ports Single port Single port Single port
Pins 16 16 16
Pitch 1.27 mm 1.27 mm 1.27 mm
Operating temperature −55 to +150 °C −40 to +85 °C −40 to +85 °C
Isolation voltage 1500 Vrms 1500 Vrms 1500 Vrms
PoE Not PoE rated 4PPoE (up to 850 mA) PoE+ (up to 720 mA)
WHS16002GMNot sure which part in the series fits? Ask our FAE team which one to sample. Get a Quote or Samples + Add to Inquiry

07FAQ

FAQ LAN Transformer: WHS16002GM

What is the operating temperature range of the WHS16002GM?

-55 °C to +150 °C, the widest in this catalogue.

For comparison, the common wide-temperature grade in the 10/100 BASE-T range is -40 °C to +85 °C and the automotive grade -40 °C to +125 °C. The WHS16002GM extends both ends. That grade addresses positions where ordinary wide-temperature parts do not survive — engine bays, downhole equipment, board positions beside high-temperature industrial processes. The deciding figure remains the measured temperature at the transformer's own location, not the ambient.

What is `Cww` in the WHS16002GM datasheet?

Inter-winding capacitance, stated on the WHS16002GM as 35 pF Max at 100 kHz and 0.1 V — the only part in this catalogue that lists it.

Inter-winding capacitance is the parasitic coupling between the chip side and the cable side. Isolation hipot governs whether the barrier withstands high voltage; inter-winding capacitance governs how much high-frequency common-mode noise crosses that barrier. The lower the figure, the less common-mode interference from the cable couples into the PHY side. Where EMC margin is tight, or radiated emissions are being estimated up front, this is a number that can be used directly.

WHS16002GM or WHS16002GA — how is the choice made?

Land pattern, outline, internal structure, cross talk and common-mode rejection are all the same; two things decide it — temperature range and stated qualification. The WHS16002GM is rated -55 °C to +150 °C and additionally states inter-winding capacitance; the WHS16002GA is rated -40 °C to +125 °C and states AEC-Q200 tested.

In short: the automotive claim points to the WHS16002GA, the more extreme temperature range to the WHS16002GM. The two cannot be had together, so tell us if a design needs both and we will confirm what is available.

08Support

Talk to an engineer

REQUEST TYPE

Choose a Request Type and Fill in the Fields

WHS16002GM

Choose a type, fill in the fields, and leave your contact details. Enter "Not sure" for any unknown parameter.

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohu.cn with your name and company, and our engineers will handle them together with this request.

  • VOOHU
  • Founded in 2018
  • Suzhou, China
  • 1,500+ customers
  • FAE support