Push-pull transformer selection comparison: VOOHU WH41-111 and Würth Elektronik 78931812505 replacement evaluation

VOOHU Technical Team ·Published ·3 min read
Alternative part Check first
Your part · Würth Elektronik 78931812505
VOOHU alternative WH41-111
ParameterWürth Elektronik 78931812505VOOHU WH41-111
Turns ratio n, (1-3):(6-4)1:1.13, ±2%1:1.1

Report conclusionSimilar values do not prove a direct replacement;

Compiled from both manufacturers' published datasheets. Verify with samples and the PCB footprint before production.

#1. Competitor Product Overview (Würth Elektronik)

For a center-tapped push-pull supply or isolated-interface design, Würth Elektronik 78931812505 is a 1208, six-pin WE-PSPA push-pull transformer. Its two winding groups use terminals 1-2-3 and 6-5-4. In a cross-reference evaluation, turns ratio, volt-second capability, insulation-test conditions and PCB land pattern should be checked together.

#2. VOOHU Replacement Overview (Suzhou VOOHU Electronic Technology Co., Ltd.)

VOOHU WH41-111 is a six-pin push-pull transformer using the same two center-tapped terminal groups, 1-2-3 and 6-5-4, with a 1:1.1 turns ratio. Its maximum length is 12.6 mm and maximum height is 4.1 mm, placing it in the same screening set for this type of push-pull design. Before adoption, verify left/right terminal positions, land dimensions, core operating margin and insulation-test duration.

#3. Key Parameter Comparison

This table keeps only parameters that map to the same terminal function on both parts. Similar values do not prove a direct replacement; items with different test conditions or recommended lands must be checked under the original design conditions.

ParameterWürth Elektronik 78931812505VOOHU WH41-111
Terminal layout / winding topology6 pins; two center-tapped winding groups: 1-2-3 and 6-5-46 pins; two center-tapped winding groups: 1-2-3 and 6-5-4
Turns ratio n, (1-3):(6-4)1:1.13, ±2%1:1.1
Insulation test voltage2500 V(AC), 1 mA / 1 s2.5 kV(AC), 1 mA / 60 s
Volt-second capability, ∫Udt9.5 Vµs (N(1-2))8.6 Vµs (N1, bipolar waveform)
Leakage inductance≤600 nH (100 kHz / 100 mV)≤1.0 µH (100 kHz / 0.01 V)
Maximum body length12.6 mm max.12.6 mm max.
Maximum height4.1 mm max.4.1 mm max.
Tape-and-reel quantity900 pcs / reel800 pcs / reel

Notes:

  1. 1.The 1-2-3 / 6-5-4 functional positions match, but the recommended land patterns are not identical. Check pad geometry, terminal landing points, stencil apertures and assembly clearance; six pins plus matching length and height are not proof of P2P interchangeability.
  2. 2.Both parts show a 2.5 kV AC insulation test, but the applied duration differs. Confirm the hipot criterion, lot-sampling plan and system safety requirement during sample validation.
  3. 3.DC-resistance definitions differ: Würth Elektronik lists (1-2), (2-3), (6-5) and (5-4) separately, while WH41-111 lists the total 1-3 and 6-4 windings. The values are not suitable for a direct numerical comparison.

#4. Applications

  1. 1.Push-pull DC/DC supplies using a six-pin center-tapped transformer, with schematic polarity and rectifier or driver connections checked first.
  2. 2.Gate-drive isolation supplies and low-voltage isolated power stages using bidirectional core magnetization, with frequency, duty cycle and volt-second margin calculated before sampling.
  3. 3.Existing-board sourcing changes or new-project introduction after PCB-overlay review, sample reflow and full-load temperature-rise verification.

#5. FAQ

Can WH41-111 directly replace 78931812505?

No direct conclusion should be drawn from pin count, outline and a similar turns ratio. Recommended lands, leakage-inductance test conditions, volt-second sampling conditions and insulation-test duration differ, so PCB review and sample-on-board validation are required.

Why is turns ratio alone not enough for a push-pull transformer?

Turns ratio is only part of the voltage-transfer relationship. Volt-second capability, switching frequency, duty cycle, leakage inductance, winding polarity and rectification all affect core margin, switching spikes and output behavior.

How should leakage inductance be checked?

Match frequency, test voltage, shorting method and measurement terminals before comparing values. The two entries here use different test voltages, so 600 nH and 1.0 µH should not be treated as a direct performance ranking.

When should the insulation test be repeated?

Repeat system-level verification whenever the transformer, PCB spacing, potting material or safety class changes, using the actual test duration, current and pass/fail criterion for the end product.

#Why VOOHU?

One-stop sourcing:connectors + magnetics + interface chips, full support from selection to small-batch production.

Custom solutions:just share your application requirements and budget to get a tailored solution with professional technical support.

Fast development:direct from the manufacturer, rapid FAE response, efficient sampling, shorter time-to-market.

Core qualifications:ISO9001, ISO14001, RoHS, REACH; two in-house factories ensure delivery and quality.

For more information, visit VOOHU: China www.voohu.cn | Overseas www.voohuele.com | Technical support: song.lei@voohu.cn

#Replacement Cross-Reference

Manufacturer: Würth Elektronik | Part number: 78931812505 | Key comparison points: six-pin center-tapped topology, 1:1.13 turns ratio, 2.5 kV AC insulation test and 9.5 Vµs. VOOHU WH41-111 is a candidate for replacement evaluation; validate the PCB and samples before release.

SAMPLES & SUPPORT

Need a quote, samples or selection support?

Part number WH41-111 is filled in for you. Add the quantity and lead time and submit. Our FAE team will be glad to confirm the options for your project.

Before you order: samples, MOQ, lead time and import duties in our ordering guide →

REQUEST TYPE

Choose a Request Type and Fill in the Fields

Part number decided; you need samples, pricing, or lead time

Contact Details

Have attachments? Send datasheets, BOMs, or drawings to voohu@voohu.cn with your name and company, and our engineers will handle them together with this request.
  1. You see a confirmation right after submitting, and the request goes to our engineering queue

  2. Pricing and lead time within 1 business day; items without stock data are marked "To be confirmed"

  3. If information is missing, we list what we need first instead of closing the request

VOOHU Technical TeamVOOHU FAEs and product engineers sharing selection, cross-reference and troubleshooting know-how for communication components. About the team →