Compiled from both manufacturers' published datasheets. Verify with samples and the PCB footprint before production.
Start with the clearance above the part, not with the pads. The VOOHU WHSG24F01ATG is a functional alternative to the Bourns PT61022XEL — verify with samples in your design. On paper the two parts are close: 24 SMD pins on a 0.99 mm pitch, one 10/100/1000BASE-T port, an operating range of −40 to +85 °C, and matching signal names from pin 1 through pin 24. The electrical tables agree on turns ratio (1CT:1CT ±5%), OCL (350 µH minimum at 8 mA DC bias), leakage inductance (0.5 µH maximum), insertion loss (−1.1 dB maximum) and hipot (1500 V, 1 mA, 60 s). Even the outline and pad drawings share their nominal dimensions. What differs is the tolerance written around those numbers, the height to plan for, and the way the two limit tables slice return loss, common mode rejection and crosstalk by frequency.

PT61022XEL datasheet: what the suffix tells you
The Bourns figures in this article come from the PT61022XEL datasheet, REV. 12/18: outline, recommended layout, schematic and electrical table on page 1, reflow profile and packaging on page 2. Its How To Order block decodes the part number. PT61022 is the model, X marks the extended temperature range, E is tape and reel with 500 pieces, and L is a tin-only termination. This sheet covers the X version; if your BOM carries a PT61022 part number without the X, work from that part's own datasheet. The VOOHU figures come from the WHSG24F01ATG datasheet, Rev A0, with the outline, pads and schematic on page 1 and the electrical table on page 2.
PT61022XEL vs. WHSG24F01ATG: datasheet values side by side
Same nominal outline, wider tolerance band: drawing the keep-out
Put the two outline drawings next to each other and the nominal numbers agree one for one: 13.56 mm body length, 15.24 mm body width, 18.65 mm across the leads, a 10.89 mm lead row, 0.41 mm leads on a 0.99 mm pitch. The tolerances do not agree. Bourns holds the body and the span across the leads to ±0.25 mm; VOOHU holds them to ±0.50 mm. Across the leads, that is 18.40 to 18.90 mm for the PT61022XEL and 18.15 to 19.15 mm for the WHSG24F01ATG (calculated). If the courtyard and any component keep-out are drawn to the wider band, 19.15 mm across the leads and 14.06 mm along the lead rows (calculated), the outline takes in the full tolerance range printed on both drawings.
The recommended pads look at the same question from the board side. Both drawings put the outer pad edges 20.0 mm apart and make each pad 2.54 mm long, so even at the top of the VOOHU tolerance the lead tips stay about 0.425 mm inside the outer pad edge on each side (calculated).
The one pad dimension that changes is the width: 0.6 mm on the Bourns recommended layout, 0.64 mm typical on the VOOHU suggested layout. On a 0.99 mm pitch that leaves a gap of 0.39 or 0.35 mm between neighboring pads (calculated). Decide which width you release, set the stencil aperture from that pad rather than from either datasheet, and look at the first assembled boards for bridging between pins and for the side fillets. Foot length also differs a little, 1.06 mm on the Bourns drawing against 1.00 ± 0.15 mm on the VOOHU drawing, so include the foot in the same first-article check.
Height: plan the vertical clearance to 6.60 mm
Both drawings dimension height from the top of the body to the seating plane at the bottom of the leads. Bourns prints 5.79 mm (0.222 in as printed). VOOHU specifies 6.10 ± 0.50 mm, which runs from 5.60 to 6.60 mm (calculated). If a shield can, a light pipe, an enclosure rib or a stacked board sits above the transformer, rerun the vertical clearance with 6.60 mm rather than with either nominal figure. For the Bourns side of any comparison, use Bourns's current drawing or a measured part, and measure the first WHSG24F01ATG samples on your own fixture before you sign off the mechanical stack.
Reading two limit tables that split the frequency range differently
Most of the electrical table carries straight across: turns ratio, OCL, leakage inductance, the insertion loss limit, hipot and operating range all read the same, and both tables are headed 25 °C. Three areas need a closer read.
- Return loss. Both tables start at −18 dB and finish at −12 dB for 60–80 MHz and −10 dB at the top. In between, Bourns writes one band, −14 dB from 30 to 60 MHz; VOOHU writes two spot points, −14.4 dB at 40 MHz and −13.1 dB at 50 MHz. Bourns's last band covers 80–100 MHz, while VOOHU's last point is 100 MHz.
- Common mode rejection and crosstalk. Bourns splits each into two bands: −35 dB from 0.3 to 60 MHz, then −30 dB for CMR and −28 dB for crosstalk from 60 to 100 MHz. VOOHU gives a single minimum for each, −30 dB from 1 to 100 MHz.
- Start frequency. Bourns specifies insertion loss, return loss, CMR and crosstalk from 0.3 MHz; VOOHU starts at 1 MHz.
None of this tells you which part does better on your board. It tells you that a limit line copied from one table may have no matching row in the other. If your design review or EMC plan quotes Bourns bands, measure both parts on your PHY board at the frequencies that plan uses, or ask us for WHSG24F01ATG data at those points.
A few single lines finish the comparison. DCR is 0.9 Ω max on the Bourns sheet and 1400 mΩ (1.4 Ω) max on the VOOHU sheet; if any calculation in your design uses the DCR figure, rerun it with the VOOHU value. Bourns also gives interwinding capacitance, 25 pF typical at 100 kHz. The VOOHU sheet does not list it, so ask us if your isolation or common mode analysis depends on that number. Storage temperature is −40 to +125 °C for Bourns and −40 to +85 °C for VOOHU, and a warehouse or transport specification written from the Bourns line needs its own WHSG24F01ATG entry. Finally, Bourns states a tin terminal finish and a reflow profile peaking at 250 ± 3 °C with 60 to 150 s above 217 °C. The VOOHU datasheet states neither, so request both before your EMS partner sets up the line.
Swap checklist: PT61022XEL to WHSG24F01ATG
Where the WHSG24F01ATG fits
The WHSG24F01ATG is a 24-pin SMD transformer for one gigabit copper port beside a plain RJ45 jack, in non-PoE designs specified for −40 to +85 °C. On a board laid out around the PT61022XEL's 0.99 mm-pitch package, its outline carries the same nominal dimensions, which leaves tolerance, height and the limit tables as the items to work through.
For PoE, a different pin count or a two-port layout, compare the alternatives in our Ethernet transformers range.
FAQ
What is a Bourns PT61022XEL equivalent?
The VOOHU WHSG24F01ATG is a functional alternative — verify with samples in your design. The two share the 24-pin, 0.99 mm-pitch SMD package dimensions in nominal terms, the pin names, the −40 to +85 °C operating range and the main electrical limits, including OCL, insertion loss and the 60 s hipot. Plan the keep-out to the VOOHU ±0.50 mm tolerance and the vertical clearance to 6.60 mm, and check the return loss, CMR and crosstalk bands against your verification plan.
What is the PT61022XEL pinout?
Pins 1 to 12 are the chip side, in groups of three per channel: TCT1, TD1+, TD1− on pins 1–3 through TCT4, TD4+, TD4− on pins 10–12. Pins 13 to 24 are the line side, from MX4−, MX4+, MCT4 on pins 13–15 to MX1−, MX1+, MCT1 on pins 22–24. The WHSG24F01ATG uses the same signal name on each pin number.
What is the difference between the PT61022EL and the PT61022XEL?
In the PT61022XEL datasheet's How To Order block, X stands for the extended temperature range; the sheet covers the X version, rated −40 to +85 °C operating. For a PT61022 part without the X, check that part's own Bourns datasheet. The WHSG24F01ATG is rated −40 to +85 °C operating.
Will the WHSG24F01ATG fit under the same height clearance as the PT61022XEL?
Plan for 6.60 mm. The VOOHU drawing gives 6.10 ± 0.50 mm from the top of the body to the seating plane, so the upper limit is 6.60 mm (calculated). The Bourns drawing prints 5.79 mm (0.222 in as printed); confirm the Bourns figure against Bourns's current drawing or a measured part, and measure the first WHSG24F01ATG samples in your enclosure.
Request WHSG24F01ATG samples for your enclosure
The height and tolerance questions are answered fastest on your own board, under your own enclosure. When you request WHSG24F01ATG samples, send the clearance available above the transformer, your pad and stencil drawing, and any frequency points your verification plan quotes. Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Our FAE team can suggest suitable parts and help check the design — for this pair, checking your keep-out and pad drawing against the WHSG24F01ATG outline and the measurement frequencies your plan needs. VOOHU supplies RJ45 and SFP connectors, LAN and PoE transformers and common mode chokes from Suzhou, China, to more than 1,500 customers.
Related product: WHSG24F01ATG. This 24-pin SMD gigabit transformer for a single port measures 18.65 ± 0.50 mm across its 0.99 mm-pitch leads and 6.10 ± 0.50 mm in height. Its datasheet lists 350 µH minimum OCL with 8 mA DC bias, DCR of 1400 mΩ maximum, return loss of −18 dB minimum from 1 to 30 MHz, a hipot rating of 1500 VAC, 1 mA, 60 s, and operation from −40 to +85 °C.
Sources
- Bourns PT61022XEL 10/100/1000 Base-T Transformer datasheet, REV. 12/18, pages 1–2.
- VOOHU WHSG24F01ATG datasheet, Rev A0, pages 1–2.
Need a quote, samples or selection support?
Part number WHSG24F01ATG is filled in for you. Add the quantity and lead time and submit. Our FAE team will be glad to confirm the options for your project.