Compiled from both manufacturers' published datasheets. Verify with samples and the PCB footprint before production.
The VOOHU SYT111B002AA2A1D can be evaluated as a functional alternative to the HALO HFJ11-2450E-L12RL — verify with samples in your design. Both are 1x1 tab-down 10/100BASE-TX RJ45 jacks with integrated magnetics, green LED on the left and yellow on the right. The PHY-side pins carry the same names one for one: TD± on 1 and 2, RD± on 3 and 6, center taps on 4 and 5, pin 8 to chassis through 1000 pF / 2 kV. Measured from the locating posts, the signal holes, LED holes and the posts themselves sit in the same places. Three things change. The shield-pin holes are Ø1.60 mm, 15.49 mm apart on HALO's footprint and Ø1.63 mm, 15.75 mm apart on VOOHU's. HALO's family drawing shows panel ground tabs; the SYT111B002AA2A1D drawing shows none. And HALO lists 0 to 70 °C for this part number, with −40 to +85 °C sold as HFJ11-E2450E-L12RL; VOOHU lists −40 to +85 °C.

What L12, RL and the E prefix mean on the HALO HFJ11 family sheet
If you downloaded a datasheet for HFJ11-2450E-L12RL, you most likely have HALO's family sheet for its 1x1 tab-down 10/100BASE-TX FastJacks, revised 11/2017: three pages covering a whole table of part numbers. Every HALO figure in this article comes from that family sheet. HALO notes that part-specific datasheets are available, and where the two disagree, the part-specific drawing for HFJ11-2450E-L12RL is the one to follow. Read the table row by row and the part number decodes itself. Each LED option has two part numbers: one in the Standard Temp column (0 to 70 °C) and one with an E after "HFJ11-" in the Extended Temp column (−40 to +85 °C). The L code gives the LED colors, left/right: L12 is green/yellow, L11 green/green, L21 yellow/green, and other codes cover bi-color LEDs. All of these use footprint C. For a second source, that means the full part number has to go on the AVL. "HFJ11-2450E" alone covers both temperature grades and several LED layouts, and the SYT111B002AA2A1D matches the L12 color order, not L21.
HFJ11-2450E-L12RL vs. SYT111B002AA2A1D: datasheet values side by side
HFJ11-2450E-L12RL footprint: what carries over and what does not
Put both drawings on the same datum, the centerline through the two locating posts, and most of the footprint lines up. The eight Ø0.89 mm signal holes sit on the same 1.27 / 2.54 mm grid at 6.35 and 8.89 mm from that line, the four Ø1.02 mm LED holes sit 4.06 mm from it, and the posts are 11.43 mm apart on both. The posts differ only in hole size, Ø3.25 mm on HALO's footprint and Ø3.20 mm on VOOHU's. The shield pins are where the two part ways. Both drawings put them 3.05 mm from the centerline, but 15.49 mm apart on HALO's footprint and 15.75 mm on VOOHU's, so each VOOHU shield pin lands about 0.13 mm further out per side (calculated), and the recommended hole is Ø1.63 instead of Ø1.60 mm. Don't assume an existing HALO footprint will take the VOOHU shield pins. Overlay the two drawings in your CAD tool, try-fit samples in a board drilled to your current footprint, and if you want one footprint that takes either part, ask us to review it before you change the drill file.
RJ45 shield ground at the front panel: HALO's ground tabs and a jack without them
HALO's family drawing shows panel ground tabs on the shield: curved spring tabs above and below the front of the jack, and further tabs on the top and sides in the front view. HALO also lists shielded versions without ground tabs, so the drawing describes the standard tabbed build. The SYT111B002AA2A1D drawing shows no panel ground tabs on any view, and its product page lists EMI gasket as No. Its shield still has the two PCB shield pins discussed above.
Whether that matters depends on your enclosure, and the person who can answer it is the one who owns the chassis grounding. Three questions settle it. First, does your design count on the jack's tabs touching the metal panel as part of the shield-to-chassis path, for ESD or emissions? If it does, that contact will not be there with the SYT111B002AA2A1D, and the path has to be reviewed. Second, does your panel cutout still suit the new body? HALO recommends 16.66 ± 0.20 × 14.72 ± 0.20 mm, printed on the same mechanical page as a 15.88 × 13.64 mm body with panel tabs. VOOHU prints no cutout, and the SYT111B002AA2A1D body is 16.00 × 13.45 mm. Third, does the front face end up where it used to? The rear face sits 10.90 mm behind the post centerline on HALO's drawing and 10.75 mm on VOOHU's. HALO gives the depth only as 21.59 mm max, so check the front face against your panel on a sample rather than by arithmetic.
LED wiring: confirm the right-hand LED before reusing the drive circuit
The left LED reads the same on both: green, anode on pin 9, cathode on pin 10. The right LED needs a check. HALO's family drawing shows the right-hand LED with its anode on pin 11. On the SYT111B002AA2A1D, the yellow LED's anode is pin 12 and its cathode pin 11. Because HALO notes that other LED polarities exist within the family, check the polarity on HALO's part-specific drawing for HFJ11-2450E-L12RL before you reuse your LED drive circuit. Then confirm on a powered sample that both LEDs light in the PHY mode you use. Recheck the current-limiting resistors as well, because the two sheets state LED data at different points: 2.1 V at 10 mA typical on HALO's, 20 mA with 1.8 to 2.8 V on VOOHU's. For why LED pin numbers and anode positions vary from jack to jack, see our RJ45 integrated magnetics pinout guide.
Temperature grade, plating and hi-pot: what to update in your documents
These lines change your paperwork more than your board. Temperature: the part number on your BOM is HALO's 0 to 70 °C grade; if your product is specified wider than that, check whether purchasing has in fact been buying HFJ11-E2450E-L12RL under the same BOM line. The SYT111B002AA2A1D comes in one grade, −40 to +85 °C. Contact plating: HALO's family sheet lists 30 µin gold minimum as a family feature; the VOOHU drawing lists 6 µin gold on the contact area without saying minimum or typical, and gives 750 mating cycles minimum. If your drawing, AVL or qualification plan names a plating thickness, update it for the new part and agree with your quality team which durability test applies. Hi-pot: HALO lists 1500 Vrms without a duration; VOOHU lists 1500 V AC and 2250 V DC for 6 s at 1 mA, so write that condition into incoming inspection. Pin length: 3.05 ± 0.51 mm on HALO's drawing, 3.60 mm on VOOHU's, so check protrusion through your board thickness and your wave-solder setup.
Swap checklist: HFJ11-2450E-L12RL to SYT111B002AA2A1D
Where the SYT111B002AA2A1D fits
The SYT111B002AA2A1D is a through-hole, single-port 10/100 MagJack (RJ45 jack with integrated magnetics) for boards built around a 10/100 PHY, including designs that started with the HFJ11-2450E-L12RL. It suits enclosures that ground the shield through its PCB shield pins rather than through panel tabs, and equipment specified for −40 to +85 °C.
If you need tabs, other LED colors or a gigabit port, compare the options in our RJ45 jacks with integrated magnetics range.
FAQ
What are the alternatives for HFJ11-2450E-L12RL from HALO Electronics?
The VOOHU SYT111B002AA2A1D is a functional alternative — verify with samples in your design. It is a 1x1 tab-down 10/100BASE-TX RJ45 jack with integrated magnetics, green/yellow LEDs and the same PHY-side pin names. Check the shield-pin holes (15.49 mm / Ø1.60 on HALO's footprint vs. 15.75 mm / Ø1.63), the panel ground tabs shown on HALO's family drawing and absent on the VOOHU part, and the right-hand LED polarity on HALO's part-specific drawing.
What is the difference between HFJ11-2450E-L12RL and HFJ11-E2450E-L12RL?
The temperature grade. On HALO's family sheet, HFJ11-2450E-L12RL is listed under Standard Temp (0 to 70 °C) and HFJ11-E2450E-L12RL under Extended Temp (−40 to +85 °C), in the same row with the same LEDs, footprint and electrical figures. The SYT111B002AA2A1D is rated −40 to +85 °C.
HFJ11-2450E-L11RL, L12RL or L21RL: what do the suffixes mean?
On HALO's family sheet the L code sets the LED colors, left/right: L11 is green/green, L12 green/yellow and L21 yellow/green. All three use footprint C. The SYT111B002AA2A1D has green on the left and yellow on the right, the L12 order.
Does the SYT111B002AA2A1D have panel ground tabs?
No. Its datasheet shows no panel ground tabs, and the product page lists EMI gasket as No. The shield connects to the PCB through two shield pins, Ø1.63 mm holes 15.75 mm apart. If your enclosure relies on tabs touching the panel, review that grounding path before you switch.
Try SYT111B002AA2A1D samples in your board and panel
A fit check on real hardware answers most of the questions above. When you request SYT111B002AA2A1D samples, add your panel cutout drawing, your board thickness and the LED mode your PHY uses. Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Our FAE team can suggest suitable parts and help check the design — for this pair, comparing your current footprint with the 15.75 mm shield-pin spacing, reviewing LED polarity against your drive circuit, and pointing you to a tabbed or different-LED part if your enclosure needs one. VOOHU supplies RJ45 and SFP connectors, LAN and PoE transformers and common mode chokes from Suzhou, China, to more than 1,500 customers.
Related product: SYT111B002AA2A1D, the 1x1 tab-down 10/100 RJ45 jack with integrated magnetics compared above: green left and yellow right LEDs, PHY-side pins TD± 1/2, RD± 3/6, center taps 4/5, two shield pins 15.75 mm apart, no panel ground tabs, 350 µH minimum OCL at 8 mA, 1500 V AC / 2250 V DC hi-pot for 6 s and a −40 to +85 °C rating.
Sources
- HALO Electronics, 10/100BASE-TX Ethernet Family of FastJacks, 1x1 Tab-Down family datasheet, revised 11/2017, pages 1–3.
- VOOHU SYT111B002AA2A1D datasheet, Rev A0; product page specifications.
Need a quote, samples or selection support?
Part number SYT111B002AA2A1D is filled in for you. Add the quantity and lead time and submit. Our FAE team will be glad to confirm the options for your project.
Before you order: samples, MOQ, lead time and import duties in our ordering guide →