An Ethernet transformer has two jobs at a twisted-pair port: it isolates the cable from your board while passing the differential signal to the PHY, and the common-mode choke built in beside it rejects noise that appears on both lines of a pair. This LAN transformer application note, which also works as an Ethernet transformer application note for 10/100BASE-TX, 1000BASE-T and 2.5G/5GBASE-T, takes one discrete port from the PHY to the RJ45 jack in five steps: the reference circuit, the center taps and PoE, part selection, layout and validation. Each step links to the article that covers it in depth, and the part table in the selection section gives the datasheet page for every value.


This note is for a port built from a PHY, a single-port discrete LAN transformer and an RJ45 jack without magnetics, at the three data rates above, with or without PoE. Chip LAN parts and RJ45 jacks with integrated magnetics (MagJacks) use the same circuit in other packages; see the chip LAN transformer range and PoE MagJack selection.
Why does Ethernet need magnetics at all? IEEE 802.3 requires twisted-pair ports to keep the cable electrically isolated from the device circuits (for 1000BASE-T, in subclause 40.6.1.1), and in most designs the magnetics form that barrier. The longer answer, including noise and common-mode rejection, is in why Ethernet needs magnetics.
LAN transformer schematic: the reference circuit
Reference circuit with a discrete LAN transformer. Panels 1 and 2 show one channel: on a voltage-mode PHY the chip-side center tap goes only to a capacitor to ground, on a current-mode PHY it also goes to the PHY supply, and the cable-side center tap goes to the Bob Smith termination. Panel 3 shows a PoE port, where the cable-side center taps carry the DC power instead. The magnetics are drawn after the WHSG24701TG and WHSG24706-1PTG datasheet schematics as examples. Schematic only, with no component values: follow your PHY and transformer datasheets.
Read the circuit from the PHY outward. The PHY's MDI pairs go to the chip side of the transformer, and the cable side goes to the RJ45 jack. Each twisted pair the port uses gets its own channel: two channels for 10/100BASE-TX, four for 1000BASE-T and 2.5G/5GBASE-T. Every channel is an isolation transformer with a center tap on each winding, plus a common-mode choke on one side of it. Four connections then decide the rest of the Ethernet transformer circuit:
For how to connect an Ethernet transformer pin by pin, including choke placement and Gigabit magnetics on a 10/100 PHY, see how to connect a LAN transformer to an Ethernet PHY. For a complete Gigabit Ethernet transformer schematic with the PHY, the RJ45 jack and port protection, see the Ethernet interface reference design.
SolutionEthernetInterface + magneticsView solution →Ethernet transformer center tap and termination
On a port without PoE, the cable-side center taps take the Bob Smith termination: each center tap goes through its own resistor to one common node, and that node returns to chassis ground through a single high-voltage capacitor. TI's AN-1469 PHYTER design and layout guide suggests 75 Ω for each resistor and a 1000 pF capacitor rated at least 2 kV, and notes that this termination does not apply to Power over Ethernet applications. None of the VOOHU discrete parts in this note has the termination inside: their schematics stop at the cable-side center-tap pins (on the 24-pin parts, MCT1 to MCT4 on pins 24, 21, 18 and 15). Place the network on your board close to the transformer, with equal resistors and symmetrical traces.
The chip-side center taps are a separate question that depends on the PHY's line driver; see voltage-mode vs current-mode PHY and the center tap. Resistor and capacitor details, unused pairs on 10/100 ports and MagJacks with the network built in are in our Bob Smith termination guide.
LAN transformer PoE: what changes in the circuit?
IEEE 802.3 Clause 33 delivers PoE as a DC voltage between two pairs (Clause 145 extends it to four-pair power, with the voltage between two pair sets); on a port with discrete magnetics, it enters and leaves through the cable-side center taps. The PSE or PD circuit connects there instead of the Bob Smith network, so the magnetics need a PoE current rating. Three things change on the datasheet. First, the open-circuit inductance (OCL) of the PoE parts in this note is specified with a 14 mA DC bias, where the Gigabit part without PoE uses 8 mA. Second, the datasheet states a current: the WHSG24706-1PTG lists "IEEE802.3at compliant performance---720mA Current Capability", and the WHSQ24706-2PTG lists "PoE Support 60W: Each channel support 1200mA DC balance current". Third, the schematic changes: in the VOOHU PoE datasheets read for this note, the common-mode choke is drawn on the chip side and the cable-side center taps come straight out to the MCT pins, which become the PoE injection points.
Ask our FAE team how the 720 mA figure applies to your PSE or PD topology before you size the center-tap copper; the WHSQ24706-2PTG datasheet states its 1200 mA per channel, and its 60 W figure is quoted here as stated in the datasheet. For how PoE current figures are read across pairs and ports, see LAN transformer selection Part 1 and PoE MagJack selection.
How do you choose the LAN transformer for each data rate?
Start from the PHY: its datasheet sets the data rate, the number of channels and the turns ratio, and often lists qualified magnetics. Then narrow the transformer down by five checks, in this order:
- 1.Data rate and bandwidth. Match the datasheet title to the port and check the frequency range over which insertion loss and return loss are specified; it differs from part to part, as the part table below shows.
- 2.PoE. If the port carries PoE, choose a part whose datasheet states a PoE current. The parts without a PoE line in the table are for ports without PoE.
- 3.OCL and its test condition. The value is printed with its test frequency, voltage and any DC bias. Compare candidates at the same condition, not by the headline value.
- 4.Operating temperature. Ranges differ even within one family: the WHSG24701TG is rated -40 to +85 °C and the WHSG24701G 0 to +70 °C.
- 5.The schematic, not only the electrical table. This matters most when you change parts or add a second source. The WHS16002GA and the WHD12501G are both 10/100BASE-TX parts with 350 µH OCL at 8 mA DC bias, but the first brings each center tap out on its own pin with the choke on the chip side, while the second joins the chip-side center taps on pin 3 and the cable-side ones on pin 10, with the choke on the cable side. A swap changes both the center-tap network and the choke position, so compare schematics before you approve it.
For a new design, these are the starting points: WHS16002GA for a 10/100BASE-TX port, including one that must run from -40 to +125 °C; WHSG24701TG for a Gigabit port without PoE; WHSG24706-1PTG for a Gigabit PoE port; WHSQ24701G for a 2.5G/5G port without PoE; and WHSQ24706-2PTG for a 2.5G/5G PoE port. Each datasheet line is explained in how to read an Ethernet transformer datasheet, and the full set of selection parameters, from pairs and ports to PoE, is in LAN transformer selection Part 1. To compare every option, open the LAN transformer selector filtered to 10/100BASE-TX, 1000BASE-T or 2.5G/5GBASE-T.
VOOHU LAN transformer part table
All six are single-port SMD parts with a 1CT:1CT ±5% turns ratio and an isolation Hi-pot of 1500 VAC, 1 mA, 60 s. Values are copied from each datasheet's electrical specifications at 25 °C, with the test conditions as printed.
Ethernet magnetics design guide: the layout checklist
Layout decides whether the isolation and common-mode rejection you selected survive on the board. Go through these points before you release the layout; the reasons and drawings are in Ethernet magnetics PCB layout, and most of the figures come from TI's Ethernet PHY PCB Design Layout Checklist (SNLA387).
How do you validate the port?
Validate in the order in which faults are cheapest to find:
- 1.First boards. Before power-up, check orientation, pin 1 and both center-tap networks against the datasheet schematic.
- 2.Isolation. IEEE 802.3 requires the isolation between the MDI leads and the device circuits, including frame ground, to withstand one of three tests: 1500 V rms at 50–60 Hz for 60 s, 2250 V dc for 60 s, or ten 2400 V impulses of 1.2/50 µs (subclause 40.6.1.1 for 1000BASE-T; check the isolation subclause for your PHY type). Each VOOHU transformer in this note is rated for an isolation Hi-pot of 1500 VAC, 1 mA, 60 s. A port-level test also stresses the termination capacitor, any part returned to chassis and the PCB gap, so test the finished board as your product standard requires. If a port fails, see why an Ethernet port fails the Hi-Pot test.
- 3.Signal. Run the IEEE 802.3 compliance tests for your data rate. Which test items depend on the magnetics is in the Ethernet conformance testing guide; what to check when a port fails is in Ethernet compliance testing failed? Magnetics checks.
- 4.PoE. Run the port with data traffic at the highest PoE current your design delivers, and check link stability and the transformer temperature against its operating range.
LAN transformer application note FAQ
What is the difference between two Ethernet transformers with the same data rate?
Often the schematic rather than the headline numbers. Compare how the center taps are brought out, which side the common-mode choke sits on, the OCL test condition, the loss frequency ranges, the operating temperature and, for PoE, the stated current. The VOOHU WHS16002GA and WHD12501G are both 10/100BASE-TX with 350 µH OCL at 8 mA DC bias, yet one has separate center taps and a chip-side choke, the other joined center taps and a cable-side choke. Send both part numbers and our FAE team can compare them line by line.
Can I use a LAN transformer without a PoE rating on a PoE port?
Not where the PoE current flows through the transformer's cable-side center taps. That current needs magnetics whose datasheet states a PoE current, such as the WHSG24706-1PTG for Gigabit or the WHSQ24706-2PTG for 2.5G/5G ports. A part with no PoE line in its datasheet, such as the WHSG24701TG, belongs on ports without PoE.
Does Bob Smith termination go on a PoE port?
Not in the 75 Ω and 1000 pF form described above. TI's AN-1469 states that Bob Smith termination does not apply to Power over Ethernet applications; on a PoE port the cable-side center taps connect to the PSE or PD circuit instead. How PoE MagJacks arrange the termination is covered in our Bob Smith termination guide.
Is Ethernet galvanically isolated?
Yes for twisted-pair Ethernet ports built to IEEE 802.3. The standard requires electrical isolation between the cable's MDI leads and the device circuits, including frame ground, and specifies how it is tested (subclause 40.6.1.1 for 1000BASE-T). In most designs the LAN transformer forms that barrier. Each VOOHU transformer in this note is rated for an isolation Hi-pot of 1500 VAC, 1 mA, 60 s.
Get your Ethernet port magnetics checked
Starting a new port, or qualifying a second magnetics source? Send the PHY part number, the data rate, whether the port carries PoE and at what current, and your temperature range through our sample request form. Our FAE team can suggest suitable parts and help check the design: the chip-side and cable-side center-tap networks, the choke position for your PHY, and the PoE current against the datasheet. Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. VOOHU supplies RJ45 and SFP connectors, LAN and PoE transformers and common mode chokes from Suzhou, China, to more than 1,500 customers.
Sources
- VOOHU WHS16002GA LAN transformer datasheet, Rev. A0: schematic, page 1; electrical specifications, page 2.
- VOOHU WHD12501G LAN transformer datasheet, Rev. A0: schematic, page 1; electrical specifications, page 2.
- VOOHU WHSG24701TG LAN transformer datasheet, Rev. A0: schematic, page 1; electrical specifications, page 2.
- VOOHU WHSG24701G LAN transformer datasheet, Rev. A0: schematic, page 1; electrical specifications, page 2.
- VOOHU WHSG24706-1PTG LAN transformer datasheet, Rev. A0: schematic, page 1; electrical specifications, page 2.
- VOOHU WHSQ24701G LAN transformer datasheet, Rev. A0: schematic, page 1; electrical specifications, page 2.
- VOOHU WHSQ24706-2PTG LAN transformer datasheet, Rev. A0: schematic, page 1; electrical specifications, page 2.
- IEEE Std 802.3-2022, subclause 40.6.1.1, Isolation requirement (1000BASE-T).
- IEEE Std 802.3-2022, Clause 33 and Clause 145 (Power over Ethernet).
- Texas Instruments, AN-1469 PHYTER Design & Layout Guide (SNLA079D), section 2.3.
- Texas Instruments, Ethernet PHY PCB Design Layout Checklist (SNLA387).
Need a quote, samples or selection support?
Part number WHS16002GA is filled in for you. Add the quantity and lead time and submit. Our FAE team will be glad to confirm the options for your project.
Before you order: samples, MOQ, lead time and import duties in our ordering guide →