Compiled from both manufacturers' published datasheets. Verify with samples and the PCB footprint before production.
For a second source to the Pulse J00-0065NL, look at the VOOHU SYT111B002FA2A1D: it is a functional alternative — verify with samples in your design. Both are 1×1 tab-down RJ45 jacks with integrated magnetics (MagJacks) for 100BASE-TX. Their datasheets give the same pin functions, a green LED on the left and a yellow one on the right with the same LED pin polarity, 350 µH minimum OCL and 2250 V DC isolation. On the PCB, the signal-pin, locating-post and shield-pin positions match; the two LED hole rows sit 0.05 mm further out on the VOOHU drawing. Three points need a decision before release. Contact gold is 15 µin on the Pulse part and 6 µin on the VOOHU part. The Pulse electrical table lists typical values, VOOHU lists limits, and the hi-pot dwell is 1 minute against 6 seconds. And only Pulse publishes a panel cut-out.

#J00-0065NL datasheet vs. SYT111B002FA2A1D datasheet, row by row
Pulse covers the J00-0065NL in its PulseJack J0 series datasheet J403.K, a six-page document shared by the J0 series. The part-number table on page 1 assigns this part mechanical drawing E (page 4), the schematic is on page 5 and the LED data on page 6. The VOOHU datasheet, revision A0, has three pages: outline, hole layout and materials on page 1, schematic, electrical table and LEDs on page 2, wave-solder profile on page 3. One thing to know before you compare the drawings: Pulse draws its hole pattern from the component side with the port facing down the page, VOOHU with the port facing up. Turn the Pulse drawing through 180° and every pin number lands in the same place as on the VOOHU drawing. Dimensions are in millimetres; "not stated" means the datasheet gives no value.
#RJ45 gold plating: 15 µin on the J00-0065NL, 6 µin on the SYT111B002FA2A1D
The plating line is the one a quality engineer will notice first. Pulse specifies selective gold of 15 µin (about 0.38 µm) on the contact area, with the solder tails in 120 µin of tin over 50 µin of nickel. VOOHU specifies 6 µin (about 0.15 µm) of gold on the contact area. Both datasheets rate the jack for 750 mating cycles. A datasheet value is not your requirement, though, so start from your own documents. If your product specification, a customer drawing or an approved-vendor note sets a minimum gold thickness for the RJ45 contacts, compare that figure with 6 µin before approving the change. If the only reference is "per supplier datasheet", the inspection sheet simply needs the new number. Where you check plating at incoming inspection, for example by XRF on a sample per lot, set the acceptance value from the VOOHU datasheet, not from the Pulse one; and if your product specification asks for more mating cycles than the 750 both datasheets rate, run that cycle count on samples in your own test.
#Typical values on one sheet, limits on the other
Read the two electrical tables with their column headings, not just their numbers. Every Pulse transmission figure is marked TYP: −1 dB insertion loss, return loss stepping from −20 to −10 dB, crosstalk of −40 to −30 dB. A typical value describes the centre of production. It is not a guarantee, so it cannot go into an inspection sheet as a pass/fail limit. VOOHU gives the same quantities as limits, maximum insertion loss and minimum return loss, crosstalk and common-mode rejection, and the frequency bands are not the same either (insertion loss to 65 MHz on one sheet, to 100 MHz on the other). That is why the two columns cannot be ranked against each other. What you can do is write the incoming specification and the component database entry from the VOOHU limits, because those are the values the VOOHU datasheet commits to. Isolation follows the same logic. Both sheets list 2250 V DC, but Pulse holds it for 1 minute, while VOOHU holds it for 6 seconds with a 1 mA limit and also lists 1500 V AC. If a safety file or test report records this jack's isolation rating, rewrite that entry with the VOOHU conditions. Our hi-pot article explains how the jack test relates to the system-level test.
#J00-0065NL panel cutout: what happens to a front panel cut for the Pulse jack
Drawing E gives a recommended panel opening of 16.76 × 14.22 mm, with corners of R0.25 mm maximum and the lower edge 0.25 mm above the board. The VOOHU datasheet gives no panel cut-out, so a mechanical engineer keeping the existing panel has only the body outlines to work from. Against that opening, the Pulse body (16.26 × 13.84 mm, maximum values) leaves 0.50 mm in width and 0.38 mm in height. The VOOHU body (16.00 × 13.45 mm) leaves 0.76 mm and 0.77 mm. Those are paper figures from two different kinds of dimension, so treat them as a reason to test, not as a result. Both parts are listed with EMI contacts at the front, "EMI fingers" in the Pulse table and "EMI gasket" on the VOOHU product page, and neither document tells you how far they reach beyond the body. The question for the panel, then, is whether the VOOHU contacts still press against the edge of an opening sized for the Pulse part. Fit a sample behind the production panel, check EMI contact on all four sides, plug and unplug a cable a few times, and repeat the ESD discharge on the port shield. If the opening also frames a light pipe or a label, look at the visible gap at the same time.
#Holes on the PCB: two LED rows and the shield pins
Once the Pulse drawing is turned round, the signal-pin, locating-post and shield-pin positions agree, and two hole details do not. The two LED hole rows sit 3.38 and 4.90 mm from the locating-post centreline on the Pulse layout and 3.43 and 4.95 mm on the VOOHU layout, 0.05 mm further out in both rows; across the board the LED holes are 12.65 against 12.64 mm. The shield-pin holes are in the same place, 3.05 mm from the post centreline and 15.75 mm apart, but drilled Ø1.60 mm for Pulse and Ø1.63 mm for VOOHU. A 0.05 mm offset inside a Ø1.02 mm hole is small, but only a sample in your actual board, with your finished-hole tolerance, will show whether the LED leads go in without force. Three smaller notes: the post centreline sits 10.80 mm behind the jack front on the Pulse drawing and 10.75 mm on the VOOHU drawing, so the jack face moves 0.05 mm relative to your board edge and panel; Pulse marks a 2.92 mm no-trace zone at the front of the jack, which the VOOHU drawing does not show, so leave your existing keep-out as it is; and the leads have different lengths, so check protrusion against your board thickness.
#Schematic, LEDs and temperature range
For the hardware designer there is little to redraw. Both schematics put TD+ and TD− on pins 1 and 2, RD+ and RD− on 3 and 6, the centre taps on 4 and 5 and chassis ground on 8, with four 75 Ω resistors and a 1000 pF capacitor in the termination. LED pins and polarity match: green on the left, anode 9 and cathode 10; yellow on the right, anode 12 and cathode 11. The LED data is written differently, though. Pulse gives typical forward voltages of 2.2 and 2.1 V with a 2.5 V maximum, and VOOHU gives ranges at 20 mA: 1.85–2.45 V for green and 1.7–2.2 V for yellow. Whoever sized the LED resistors for the Pulse part should rerun the current at both ends of the VOOHU ranges, using your actual supply rail. The temperature lines also differ: 0 to +70 °C for the Pulse part, −40 to +85 °C for the VOOHU part. For a product specified inside 0 to +70 °C this changes only the BOM entry; if your product must work below 0 °C, the range the part was qualified over becomes part of your design review.
#Change-over checklist: J00-0065NL to SYT111B002FA2A1D
Quality and incoming inspection
- 1.Check your product specification and customer drawings for a minimum contact-gold requirement, then set the XRF or plating acceptance value from the VOOHU datasheet (6 µin).
- 2.Replace the Pulse typical values in the inspection sheet with the VOOHU limits, band by band.
- 3.Set up the hi-pot step as 2250 V DC, 6 s, 1 mA, primary to secondary, and update any safety file entry that quotes the jack's isolation.
Mechanical
- 1.Fit a sample behind the production panel (16.76 × 14.22 mm opening) and check EMI finger / gasket contact on all four sides.
- 2.Plug and unplug a cable through the panel and repeat ESD discharge on the shield.
Layout
- 1.Dry-fit a sample in a bare board from your current lot and check the LED leads in both rows (0.05 mm offset) and the shield pins (Ø1.60 mm holes).
- 2.Keep the existing no-trace zone at the front of the jack and check lead protrusion against board thickness.
Hardware
- 1.Recalculate LED current at both ends of the VOOHU forward-voltage ranges.
- 2.Copy the operating temperature (−40 to +85 °C) into the BOM from the VOOHU datasheet.
Purchasing
- 1.Add the SYT111B002FA2A1D to the approved-vendor list as a functional alternative to the J00-0065NL, pending sample approval.
#Where the SYT111B002FA2A1D fits
Single 100BASE-TX copper ports that carry data only: embedded controller and HMI boards, IP-connected meters and sensors, small gateways and network modules. Ports that deliver power are out of scope: the VOOHU product page lists this jack as not PoE rated. Pulse puts the J00-0065NL on the same schematic page as the J0011 group, and VOOHU lists the SYT111B002FA2A1D against the J0011D21BNL as well; if that is the part on your BOM, our J0011D21BNL comparison covers it.
SolutionEthernetInterface + magneticsView solution →#FAQ
What is an alternative to Pulse J00-0065NL?
VOOHU's SYT111B002FA2A1D is a functional alternative to the Pulse J00-0065NL — verify with samples in your design. Both are 1×1 tab-down 100BASE-TX RJ45 jacks with integrated magnetics, green and yellow LEDs and the same published pin functions. Check contact gold (15 vs 6 µin), the hi-pot conditions and the fit in your front panel before release.
Which pages of the J00-0065NL datasheet apply to this part?
The J00-0065NL is covered by the Pulse J0 series datasheet J403.K. Its row in the page 1 part-number table gives the turns ratio, LED colours, hi-pot value and mechanical drawing E; drawing E on page 4 has the hole pattern and the 16.76 × 14.22 mm panel cut-out, page 5 the schematic and page 6 the LED data.
What is the difference between the J00-0065NL and the J0011D21BNL?
Pulse draws both on the same schematic page of datasheet J403.K, so the pin functions are shared. Each part has its own row in the page 1 table, which sets its mechanical drawing and options; the J00-0065NL uses drawing E and the J0011D21BNL drawing B, while both rows list 1CT:1 turns ratios, EMI fingers, green/yellow LEDs and 2250 V DC. Compare the rows for the two part numbers before treating them as interchangeable.
Does gold plating thickness on an RJ45 jack matter?
It matters most where a specification sets a value for it, because then it becomes an inspection item. Both datasheets here rate 750 mating cycles, with 15 µin of gold on the Pulse J00-0065NL contacts and 6 µin on the VOOHU SYT111B002FA2A1D. If a product or customer specification calls for a minimum thickness, check it against the datasheet of the part you buy; otherwise use that datasheet's value for incoming inspection.
#Send your J00-0065NL inspection sheet and panel drawing with the sample request
Request SYT111B002FA2A1D samples through the sample request form and attach the incoming inspection sheet you use for the J00-0065NL and the drawing of your front-panel opening. Samples are available for evaluation, and selected parts are free of charge. Our FAE team will be glad to confirm the options for your project. Our FAE team can suggest suitable parts and help check the design — for this jack, rewriting your plating, electrical and hi-pot lines in VOOHU terms, reviewing the panel opening and checking the LED and shield-pin holes on your board.
VOOHU supplies RJ45 and SFP connectors, LAN and PoE transformers and common mode chokes from Suzhou, China, to more than 1,500 customers.
To compare other tab-down jacks with built-in magnetics, open the RJ45 connector selector, already filtered for both.
Related product: SYT111B002FA2A1D — 1×1 tab-down RJ45 jack with integrated magnetics, 100BASE-TX, green / yellow LEDs, EMI gasket, −40 to +85 °C.
Need a quote, samples or selection support?
Part number SYT111B002FA2A1D is filled in for you. Add the quantity and lead time and submit. Our FAE team will be glad to confirm the options for your project.
Before you order: samples, MOQ, lead time and import duties in our ordering guide →